FAB
|
Former ID
|
Synopsis
|
Last Modified Date
|
1231323.1 |
|
Relocation of the US HDS Spares Distribution Center for Storage 99xx field returns on or after October 21, 2010. |
2010-10-11
|
1020441.1 |
258488 |
Must follow Battery Management Procedures to guarantee the integrity of ST9900 products. |
2010-09-23
|
1019622.1 |
242466 |
Possible failure of multiple HDDs of certain type within the same Parity Group in ST9990V, ST9985V, ST9990 and ST9985. |
2010-11-03
|
1019433.1 |
239625 |
Requirement for SE9900 Series Arrays Microcode level to be at Mandatory General Availability (MGA). |
2011-05-12
|
1017445.1 |
228549 |
Essential Battery Management Procedures for Sun StorEdge 99x0 Products. |
2010-08-27
|
1017434.1 |
228537 |
Changes to SE99XX activation and notification process for monitored systems. |
2010-08-20
|
1017432.1 |
228535 |
Unauthorised Modifications to StorEdge 99x0 Service Processor (SVP) - Windows Operating System |
2010-11-11
|
1001324.1 |
201786 |
Effective July 13, 2006 - All Case Routing Information For Devices Using the SAMS3/ACCR SSRR HiTrack Applications For Automatic Case Creation And Routing Will Be Handled Via SunRoute. |
2010-08-25
|
1001322.1 |
201784 |
Battery Change required for selected serial numbers due to manufacturing defect. |
2010-08-24
|
1001035.1 |
201362 |
Sun StorEdge 99xx Arrays Might Encounter Data Integrity Issues After VMotion Guest Migrations. |
2010-08-26
|
1001020.1 |
201346 |
ST99xx Hitachi Hard Drives (DKR2D, DKR2E and DKR2F) reliability improvement. |
2010-10-21
|
1000866.1 |
201147 |
TagmaStore USP/NSC High Capacity Cache and Shared Memory Installation. |
2010-08-31
|
1000865.1 |
201146 |
Devices may become unavailable when attempting USP Non-Stop micro-program exchange on SE9985 or SE9990 systems |
2010-08-31
|
1000857.1 |
201138 |
Intermix of HDD from different vendors in parity is supported with pre-requisite Microcode. |
2010-08-31
|
1000853.1 |
201134 |
Enabling SE99x0 System Option Mode 186 prevents correct functioning of SCSI-2 Reservations |
2010-08-31
|
1000844.1 |
201125 |
SE9990 Parity group addition will fail if the total number of currently installed HDDs + external strorage groups + new HDDs to be installed exceeds 2560. |
2010-08-30
|
1000829.1 |
201109 |
Specified SE9990 components now require autodumps to be collected and returned on USB memory devices included with the spare PCBs(printed circuit boards). |
2010-09-10
|
1000814.1 |
201093 |
Hitrack Version B.4 And Below Might Report Incorrect Data. |
2010-09-10
|
1000705.1 |
200923 |
Hitrack versions (prior to B.2) for the SE9990 and SE9985 arrays can exit unexpectedly and may not send SIM notifications. |
2010-09-10
|
1000384.1 |
200506 |
Host Group Option 16 cannot be set from Storage Navigator |
2010-08-23
|
1000378.1 |
200500 |
Mode 80 disabled will cause "pairresync -restore" to perform a Quick Restore operation, which causes volume maps to swap and can lead to severe performance degradation. |
2010-08-23
|
1000365.1 |
200487 |
Sun StorEdge 9985 (NSC55) - False Detection of Service Processor (SVP) FAN Failure. |
2010-09-01
|
1000309.1 |
200426 |
A microcode bug exists in all V07+1 (50-07-51-00/00 and higher) microcode that in a limited number of configurations can cause all DKA MPs to blockade and recovery may be very disruptive. |
2010-08-30
|
1000222.1 |
200297 |
Multiple issues with Graphtrack versions 7.0-7.2 |
2010-11-10
|
1000171.1 |
200220 |
ECC/LRC pinned data may occur if cache blockades on SE9990/SE9985 |
2010-09-02
|