Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000309.1 : A microcode bug exists in all V07+1 (50-07-51-00/00 and higher) microcode that in a limited number of configurations can cause all DKA MPs to blockade and recovery may be very disruptive.
PreviouslyPublishedAs 200426 Product Sun StorageTek 9990 System Sun StorageTek 9985 System Bug Id None. Impact When a ShadowImage, etc., pair(s) is/are deleted, CHK3 and WCHK1 may occur in all DKAs causing all DKA MPs to be blocked. Contributing Factors Microcode Affected : This issue occurs when any of the Operations 1 through 7 are performed in a subsystem that satisfies Configurations 1 to 3 below. Root Cause During the process of deleting a ShadowImage (or other PP) pair, the microcode checks to see if the related logical volume is used for Compatible Mirroring for IBM FlashCopy Version2. The microcode unfortunately does not first validate that the SM for Compatible Mirroring for IBM FlashCopy Version2 is activated. If SM for Compatible Mirroring for IBM FlashCopy Version2 is not activated, the area of SM accessed is incorrect. Therefore, CHK3 occurs many times in the subsystem eventually resulting in WCHK1 and the DKA MPs are blocked. Resolution A) Actions to take in the case of failure: The following steps should be performed only with the guidance of technical support.
Don't upgrade the micro-program to DKCMAIN (V07+1) 50-07-51-00/00 or later. a. Downgrade the micro-program to any version earlier than DKCMAIN V07+1 50-07-51-00/00. Previously Published As 102629 Internal Comments Related Information
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Kasp FAB Legacy ID 102629 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2006-09-25 Avoidance: Firmware Responsible Manager: [email protected] Original Admin Info: null Product_uuid 15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System 73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System Attachments This solution has no attachment |
||||||||||||
|