Solution Type  FAB (standard) Sure

Solution  1000171.1 :   ECC/LRC pinned data may occur if cache blockades on SE9990/SE9985  


Related Items
  • Sun Storage 9990 System
  •  
  • Sun Storage 9985 System
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  

PreviouslyPublishedAs
200220


Product
Sun StorageTek 9990 System
Sun StorageTek 9985 System


Impact
When one side of cache is blocked due to a cache failure, ECC/LRC PIN
data can occur.  In the cache duplication process at the time of writing data to parity
groups, a cache failure can occur, and an improperly duplicated extent will be
specified due to a micro-program failure.

This issue can occur when both following conditions are met:

  • RAID1 parity groups exist in the subsystem
  • A cache failure blocks one side of cache

Affected MICRO-PROGRAM VERSIONS:

Microcode version equal to or greater than 50-04-48-00/00 can be affected by this issue.


Symptoms

 


Workaround

New release of microcode will provide a countermeasure to prevent the issue.

The resolution for this issue is to install:

  • SE9990 (USP tagmaStore) MC 50-04-49-00/00 and above.
  • SE9985 (USP/NSC55) MC 50-05-23-00/00 and above.

Previously Published As
102199
Internal Comments


Abbreviations used in this FIN.




  • ECC: Error correction code


  • LRC: Longitudinal Redundance Checksum


  • MC : Microcode


  • NSC: Network Storage Controller


  • USP: Universal Storage Platform


Related Information
  • Manual: SE99x0 Maintenance Manuals
  • URL: http://sejsc.ebay/AL/USP_045637R2.htm
    http://sejsc.ebay/AL/USP_045637_R500-PinnedData.pdf
    http://pts-storage.west/products/T99x0/documentation.html
    http://sccc-storage.emea:5071/cgi-bin/microcode/request.cgi
  • Other: Alert USP_045637

Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
KE Authors

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Kasp FAB Legacy ID
102199

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date:
Avoidance: Service Procedure
Responsible Manager: null
Original Admin Info: null

Product_uuid
15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System
73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback