Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1001035.1 : Sun StorEdge 99xx Arrays Might Encounter Data Integrity Issues After VMotion Guest Migrations.
PreviouslyPublishedAs 201362 Product Sun StorageTek 9990 System Sun StorageTek 9910 Sun StorageTek 9960 System Sun StorageTek 9970 System Sun StorageTek 9985 System Sun StorageTek 9980 System Impact After a successful VMotion guest migration, "Guest" either reports bad DLL or BSOD (Blue Screen of Death) caused by bad DLL. Sometimes these are permanently bad DLL's and require reinstalling the application. This is data corruption and it was detected in lab testing. A similar event (Bad DLL requiring customer lab to restore DLL) occurred in customer's lab. To fix this issue, VMware has generated a patch described below. Workaround
Resolution This is a third party VMware issue but affects Sun's StorEdge 99xx product line. Therefore, there is no SE99xx microcode fix required for this issue, only the VMware patch mentioned below needs to be installed when running VMotion. VMware has implemented the change into VMware GA production version ESX 2.5.3 patch 2. Hitachi Data Systems has successfully tested the ESX 2.5.3 patch 2 on all of SE99XX storage subsystems that support VMware. The patch can be downloaded by contacting VMWARE support or via the web at: http://www.vmware.com/download/esx/esx-253-200606-patch.html Previously Published As 102530 Internal Comments Related Information
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Kasp FAB Legacy ID 102530 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: 2006-07-28 Avoidance: Upgrade Responsible Manager: null Original Admin Info: null Product_uuid 15644879-f179-11d8-ab63-080020a9ed93|Sun StorageTek 9990 System 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System 4ea4b951-9fc9-4f1f-b64e-69572a400fb4|Sun StorageTek 9970 System 73084edc-dc32-11d9-8a74-080020a9ed93|Sun StorageTek 9985 System c2428fbe-8ab7-41d0-8b6e-ab489823c9d4|Sun StorageTek 9980 System Attachments This solution has no attachment |
||||||||||||
|