Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun ZFS Storage 7320 - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Fire X4170 M2 server and the Optional Sun Disk Shelf 24x3.5" SAS-2, but uses specialized components.
Only use parts listed in the Sun ZFS Storage 7320's Full Components List to service this product.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7045305 [C] 6Gbps SAS-2 Interface Module (SIM FW 3527) 7014946 [C] [S] 
n/a 542-0194 [C] [S] 6Gbps SAS-2 Interface Module (SIM FW 3520 or 3524) , n/a
n/a 7014946 [C] [S] 6Gbps SAS-2 Interface Module (SIM FW 3524 or 3527), 542-0194 [C] [S]
NOTE: 6Gbps SAS-2 Interface Module (SIM) PN#542-0194, PN#7014947 and PN#7045305 are used in the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
NOTE: Don't mix SIM card firmware 3520 with SIM card firmware 3524. See FAB 1307357.1 for details.
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-3993 [C] 3V Coin Cell Battery, n/a
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4885 [F] 2.4GHz Intel Quad-Core Xeon E5620, 12MB, 80W, n/a
n/a 541-2545 [F] Xeon Heatsink, n/a
  • 240-6751
  • Spring Screw,
n/a
  • 310-0161
  • Pre-greased Heatsink
n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
X2130A-1M-N 530-4441 [C] 10Gbps SFP+ TwinX Cable, 1m, n/a
X2130A-3M-N 530-4442 [C] 10Gbps SFP+ TwinX Cable, 3m, n/a
X2130A-5M-N 530-4443 [C] 10Gbps SFP+ TwinX Cable, 5m, n/a
XTA-2.0M-SAS 530-3883 [C] 4X Mini SAS Cable, SFF-8088 to SFF-8088, 2M, n/a
n/a 530-3771 [C] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 1m, Grey, n/a
n/a 530-3880 [C] RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 6M, n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X4242A 375-3696 [C] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter, n/a
XTA7320-CUK 2 530-3771 [C] RJ-45 Ethernet Cable (1m) n/a
542-0298 [C] Cluster Heartbeat Assembly n/a
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
X4237A-N [S] 375-3606 [C] Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express n/a
n/a 7056175 [C] Cluster Heartbeat Assembly 542-0298 [C]
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
2 Cluster Upgrade Kit includes Qty #3 PN#530-3771 and Qty #2 PN#511-1496.
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 511-1283 [F] 8-Slot Disk Backplane, SATA DVD, 511-1548 [F]
n/a 511-1548 [F] 8-Slot Disk Backplane, SATA DVD, n/a
Disks
Option # Manufacturing
Part #
Description Previous
Part #
7101195 7048042 [C] 73GB SAS-2 Solid State Drive Assembly, RoHS-2013 7011094 [C]
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • Stingray 3.5" Mounting Bracket
n/a
7101234 7010845 [C] 512GB Solid State Drive SATA-2 Assembly n/a
  • Toshiba THNSNC512GBSJ (512GB Solid State Drive), SATA-2 Interface
n/a
  • Marlin 2.5" Bracket,
n/a
DS2X-LOGZ [S] 7015704 4 [C] 18GB SAS Solid State Drive Assembly 542-0286 3 [C] [S]
  • 18GB SAS Solid State Drive,
n/a
  • Stingray 3.5" Mounting Bracket
n/a
XTA7000-READZ512 [S] 542-0330 [C] 512GB Solid State Drive SATA-2 Assembly n/a
  • Toshiba THNS512GG8BB (512GB Solid State Drive), SATA-2 Interface,
n/a
  • Marlin 2.5" Bracket,
n/a
n/a 350-1574 Disk Shelf SSD Filler Panel n/a
n/a 541-4242 Disk Shelf HDD Filler Panel, n/a
n/a 542-0179 [C] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 542-0191 [C] 300GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3300657SS [ST330057SSUN300G]
    (300GB - 15000 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 542-0274 [C] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 542-0340 [C] 1TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST31000424SS [ST31001SSSUN1.0T] (1TB - 7200 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 542-0371 [C] 500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, n/a
  • Seagate ST9500530NS [ST95000NSSUN500G]
    (500GB - 7200 RPM - SATA Disk)
n/a
  • Seagate ST9500620NS [ST95001NSSUN500G] (500GB - 7200 RPM - SATA Disk)
n/a
  • Marlin 2.5" Bracket,
n/a
n/a 7010135 [C] 3TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST33000650SS [ST33000SSSSUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Hitachi HUS723030ALS640 [H7230AS60SUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7011094 [C] 73GB SAS Solid State Drive Assembly with 1 bracket and 1 of the following disks: n/a
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7042768 [C] 500GB - 10000 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks: 542-0371 [C]
  • Western Digital WD5000BLHX [WD500BLHXSUN500G] (500GB - 10000 RPM - SATA Disk)
n/a
  • Marlin 2.5" Bracket,
n/a
n/a 7042964 [C] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUS723020ALS640 [H7220AS60SUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7047035 [C] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7047155 [C] 300GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3300657SS [ST330057SSUN300G]
    (300GB - 15000 RPM - SAS Disk),
n/a
  • Hitachi HUS156030VLS600 [HUS1530SCSUN300G]
    (300GB - 15000 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
3 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
4 SSD firmware needs to be at version 9002 or later, See FAB 1307373.1 for details.
NOTE: Stingray bracketed drives are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
NOTE: Marlin bracketed drives are used in the Sun ZFS Storage 7320 Rear Disk Module.
NOTE: 3TB Disk Assembly PN#7010135 requires Disk Shelf 24x3.5" SAS-2 Chassis Assembly PN#7041264.
NOTE: 2TB Disk Assembly PN#7042964 requires Disk Shelf 24x3.5" SAS-2 Chassis Assembly PN#7041264.
NOTE: 300GB Disk Assembly PN#7047155 requires Disk Shelf 24x3.5" SAS-2 Chassis Assembly PN#7041264.
NOTE: 18GB Solid State Drives are not qualified in Disk Shelf 24x3.5" SAS-2 Chassis Assembly PN#7041264.
NOTE: Coral bracketed drives are used in the Sun ZFS Storage 7320 server head.
NOTE: 600GB Disk Assembly PN#7047035 requires Disk Shelf 24x3.5" SAS-2 Chassis Assembly PN#7041264.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1109A-Z 375-3617 [C] Dual 10-Gigabit Ethernet SFP+ LP, n/a
X2129A-N 530-4449 [C] 10Gbps Short Wave Pluggable Transceiver (SFP+), n/a
X4446A-Z-N 375-3481 [C] PCI Express Quad Gigabit Ethernet UTP, n/a
X5562A-Z 135-1205 [C] 10Gbps Long Wave Pluggable Transceiver (SFP+) n/a
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4274 [C] Fan Board Assembly, n/a
  • 330-5274
  • Fan Deck,
n/a
  • 511-1490
  • Fan Board,
n/a
n/a 541-4276 [C] Fan Module, n/a
  • 371-4789
  • 40x56mm, 15300 RPM Fan,
n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIE2FC-QF8-N 371-4325 [C] 8Gigabit/Sec PCI Express Dual FC Host Adapter, n/a
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2883 [C] 1-Slot x8 PCI Express Riser Assembly, n/a
  • 1-Slot x8 PCI Express Riser,
n/a
  • 541-2924
  • Riser Mounting Bracket,
n/a
n/a 541-2885 [C] 1-Slot x16 PCI Express Riser Assembly, n/a
  • 1-Slot x16 PCI Express Riser,
n/a
  • 541-2924
  • Riser Mounting Bracket,
n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
X4910A 371-4965 [C] 4GB Registered DDR3-1333 DIMM, 1.35V, n/a
X4911A 371-4966 [C] 8GB Registered DDR3-1333 DIMM, 1.35V, n/a
X4850A [S] 371-4898 [C] 4GB Registered DDR3-1333 DIMM, 1.5V, n/a
n/a 371-4743 [C] 4GB USB 2.0 Flash Drive, n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2233 [C] Type A247 760 Watt AC Input Power Supply, n/a
n/a 300-2276 [C] 764 Watt AC Input Power/Cooling Module, n/a
n/a 300-2299 [C] Type A247A 760 Watt AC Input Power Supply, 300-2233 [C]
n/a 511-1489 [F] Power Distribution Board, n/a
NOTE: 764W AC Input Power Supply and Fan Assembly PN#300-2276 is used in the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
Rack
Option # Manufacturing
Part #
Description Previous
Part #
DS2X-4URK-19U 350-1531 Rackmount Kit, n/a
  • n/a
  • Right Mounting Rail
n/a
  • n/a
  • Left Mounting Rail
n/a
X6324A-N 371-2742 [C] 1U/2U Cable Management Arm, n/a
X6325A-N [S] 371-2740 [C] 1U/2U Snap-In Slide Rail Rackmount Kit, 730mm, n/a
X6326A-N [S] 371-2741 [C] 1U/2U Screw-Mount Slide Rail Rackmount Kit, 730mm, n/a
NOTE: Rackmount Kit DS2X-4URK-19U/350-1531 is used for rack mounting the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
Removable Media
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2732 [C] USB Assembly, n/a
  • 330-4418
  • DVD Interconnect Holder,
n/a
  • 341-4072
  • DVD Filler Panel,
n/a
  • USB Board,
n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3609 [C] 8-Port 6Gbps SAS-2 RAID HBA, n/a
n/a 7056272 [C] 8-Port 6Gbps SAS-2 RAID HBA 375-3609 [C]
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4081 5 [F] System Board Assembly/FRU, n/a
  • System Board,
n/a
    • 3V Coin Cell Battery,
n/a
  • 541-2543
  • System Board Tray,
n/a
5 While the system board is a FRU, Contact Oracle Support if this part is suspected to be faulty.

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 530-3927 [C] PDB to System Board Ribbon Cable,
NS 530-4228 [C] SFF8087 to SFF8087 Mini-SAS Cable, 690mm,
NS 530-4417 [C] 6-Pin Fan Power Cable,
NS 530-4431 [C] Fan Data Ribbon Cable,
NS 540-7980 [C] Disk Shelf Chassis Assembly,
NS
  • 330-5203
  • Front Left End Cap,
NS
  • 330-5204
  • Front Right End Cap,
NS
  • 375-3659
  • Centerplane Assembly,
NS 541-2075 [C] Bus Bar Set,
NS
  • 341-3096
  • Long Red Bus Bar,
NS
  • 341-3104
  • Short Blue Bus Bar,
NS 541-4275 [C] Connector Board,
NS 7041264 [C] Disk Shelf Chassis Assembly
NS
  • 330-5203
  • Front Left End Cap,
NS
  • 330-5204
  • Front Right End Cap,
NS
  • 7041262
  • Centerplane Assembly
NOTE: Disk Shelf Chassis Assembly PN#7041264 is used in the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
NOTE: Disk Shelf Chassis Assembly PN#540-7980 is used in the OPTIONAL Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Storage 7320.
NOTE: Refer to the "Disks" section of the FCL for Disk Shelf 24x 3.5" SAS-2 chassis requirements.
  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback