Problem Document
|
Former IBIS ID
|
Synopsis
|
Last Modified Date
|
1017694.1 |
228891 |
Sun StorEdge[TM] A5000: luxadm insert error: can not initialize the loop |
2011-03-03
|
1011944.1 |
216350 |
Sun StorEdge[TM] A5x00:Inquiry fails when issuing luxadm remove_device |
2010-10-29
|
1010213.1 |
214027 |
WARNING: add_spec: No major number for sf |
2010-09-13
|
1009316.1 |
212895 |
Stale or Obsolete Device Label for a Storage Device in Solaris[TM] |
2009-12-04
|
1009229.1 |
212769 |
Offlined A5x00 disks return to online state after LIP |
2010-09-14
|
1008668.1 |
211884 |
SCSI Transport errors and disks timeout failures on Sun StorEdge[TM] A5000 and T3, Sun Blade[TM] 1000 or Sun Enterprise[TM]3500 |
2009-09-17
|
1008663.1 |
211878 |
What an AEN raid event with ASC=5D ASCQ=80 means, and what to do about it. |
2009-09-14
|
1008606.1 |
211756 |
Cannot see Sun Storedge[TM] A5000 disks after install of Solaris[TM] 2.5.1 8/97 |
2009-09-13
|
1008580.1 |
211723 |
Recovering from a failed FCAL boot disk |
2011-03-03
|
1008569.1 |
211708 |
SunVTS[TM] failures with multiple SunStorEdge[TM] A5000 connected. |
2009-09-23
|
1008074.1 |
211117 |
Sun StorEdge[TM] A5x00 Array: IO become unresponsive or hang on disks |
2010-08-27
|
1007424.1 |
210256 |
How to Move a Sun Enterprise Volume Manager[TM] (SEVM) (or Veritas Volume Manager, VxVM) License From One Host to Another |
2010-10-29
|
1005730.1 |
207933 |
Sun Enterprise Volume Manager[TM] 2.X does not show both paths in DMP as valid after replacing GBIC hardware. |
2010-08-10
|
1005705.1 |
207906 |
Solaris[TM] 2.5.1 to 2.6 upgrade cannot see new Sun StorEdge[TM] A5000 (Photon) disks |
2010-09-14
|
1004620.1 |
206406 |
Sun StorEdge[TM] A5000:Symptom:luxadm Probe Returns Disk Drive Data Paths Instead of A5x00 Enclosure Information |
2010-08-10
|
1003234.1 |
204444 |
Unable to remove a disk using `luxadm remove_device enclosure,dev` |
2010-09-13
|
1003035.1 |
204157 |
Sun Enterprise Volume Manager[TM] (SEVM) 2.5/2.6: Running vxinstall on system with Sun StorEdge[TM] A5000 prompts for license |
2009-09-28
|
1002168.1 |
203073 |
Mixing Fibre Channel HBA types on private-loop configurations can cause loop offline/timeouts. |
2010-07-19
|
1001634.1 |
202221 |
luxadm probe fails to find attached Sun StorEdge[TM] A5000 |
2009-09-30
|
1001617.1 |
202203 |
Disk Device Links in /dev/[r]dsk Do Not Get Created |
2010-07-19
|
1001492.1 |
202046 |
"Lost Frame 0x14" errors with 18GB FC drives in Sun StorEdge[TM] A5X00's and Sun Enterprise[TM] 3500's |
2009-09-27
|