Symptoms
A disk or disks that have been placed in an offline state via the
luxadm -e offline <path> command are returned to an online state
following a luxadm remove of a different disk.

Resolution
The luxadm remove command forces the link to reinitialize, using the Loop Initialization Primitive (LIP) sequence. This LIP process causes all devices to participate in loop initialization. Previously off-lined A5x00 disks will come online.
Other commands and actions that can cause similar behavior are
the luxadm -e forcelip, luxadm insert,a host reboot or any physical change in the loop.
See the following example which illustrates this behavior.
hostA# luxadm display MINE
				   SENA
DISK STATUS
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      On (O.K.)         200000203704faa8    On (Loop not accessible)
1      On (O.K.)         20000020370709ec    On (Loop not accessible)
2      On (O.K.)         20000020370707fa    On (Loop not accessible)
3      On (O.K.)         20000020371636bd    On (Loop not accessible)
4      On (O.K.)         20000020370d6676    Not Installed
5      On (O.K.)         2000002037145a35    On (Loop not accessible)
6      On (O.K.)         2000002037070913    On (Loop not accessible)
SUBSYSTEM STATUS
FW Revision:1.09   Box ID:2   Node WWN:5080020000000550   Enclosure Name:MINE
Power Supplies (0,2 in front, 1 in rear)
	0 O.K.(rev.-02)	1 O.K.(rev.-02)	2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
	0 O.K.(rev.-05)	1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
	A: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 Failed(mod.-05): Not receiving a signal
		1 Not Installed
	B: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 O.K.(mod.-05)
		1 Not Installed
Disk backplane (0 in front, 1 in rear)
	Front Backplane: O.K.(rev.-05)
	  Temperature sensors (on front backplane)
	  0:42?C 1:42?C 2:40?C 3:39?C 4:40?C 5:40?C
	  6:43?C  (All temperatures are NORMAL.)
	Rear Backplane:  O.K.(rev.-05)
	  Temperature sensors (on rear backplane)
	  0:40?C 1:42?C 2:40?C 3:39?C 4:39?C 5:39?C
	  6:42?C  (All temperatures are NORMAL.)
Interconnect assembly
	O.K.(rev.-03)
Loop  configuration
	Loop A is configured as two separate loops.
	Loop B is configured as two separate loops.
Language        USA English
hostA# luxadm -e offline /dev/rdsk/c3t66d0s2
hostA# luxadm display MINE
				   SENA
DISK STATUS
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      On (O.K.)         200000203704faa8    On (Loop not accessible)
1      On (O.K.)         20000020370709ec    On (Loop not accessible)
2      On (No path found)20000020370707fa    On (Loop not accessible)
3      On (O.K.)         20000020371636bd    On (Loop not accessible)
4      On (O.K.)         20000020370d6676    Not Installed
5      On (O.K.)         2000002037145a35    On (Loop not accessible)
6      On (O.K.)         2000002037070913    On (Loop not accessible)
SUBSYSTEM STATUS
FW Revision:1.09   Box ID:2   Node WWN:5080020000000550   Enclosure Name:MINE
Power Supplies (0,2 in front, 1 in rear)
	0 O.K.(rev.-02)	1 O.K.(rev.-02)	2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
	0 O.K.(rev.-05)	1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
	A: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 Failed(mod.-05): Not receiving a signal
		1 Not Installed
	B: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 O.K.(mod.-05)
		1 Not Installed
Disk backplane (0 in front, 1 in rear)
	Front Backplane: O.K.(rev.-05)
	  Temperature sensors (on front backplane)
	  0:42?C 1:42?C 2:40?C 3:39?C 4:40?C 5:42?C
	  6:43?C  (All temperatures are NORMAL.)
	Rear Backplane:  O.K.(rev.-05)
	  Temperature sensors (on rear backplane)
	  0:40?C 1:42?C 2:40?C 3:39?C 4:39?C 5:39?C
	  6:42?C  (All temperatures are NORMAL.)
Interconnect assembly
	O.K.(rev.-03)
Loop  configuration
	Loop A is configured as two separate loops.
	Loop B is configured as two separate loops.
Language        USA English	
hostA# luxadm -e forcelip
hostA# luxadm display MINE
				   SENA
DISK STATUS
SLOT   FRONT DISKS       (Node WWN)          REAR DISKS        (Node WWN)
0      On (O.K.)         200000203704faa8    On (Loop not accessible)
1      On (O.K.)         20000020370709ec    On (Loop not accessible)
2      On (O.K.)         20000020370707fa    On (Loop not accessible)
3      On (O.K.)         20000020371636bd    On (Loop not accessible)
4      On (O.K.)         20000020370d6676    Not Installed
5      On (O.K.)         2000002037145a35    On (Loop not accessible)
6      On (O.K.)         2000002037070913    On (Loop not accessible)
SUBSYSTEM STATUS
FW Revision:1.09   Box ID:2   Node WWN:5080020000000550   Enclosure Name:MINE
Power Supplies (0,2 in front, 1 in rear)
	0 O.K.(rev.-02)	1 O.K.(rev.-02)	2 O.K.(rev.-02)
Fans (0 in front, 1 in rear)
	0 O.K.(rev.-05)	1 O.K.(rev.-00)
ESI Interface board(IB) (A top, B bottom)
	A: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 Failed(mod.-05): Not receiving a signal
		1 Not Installed
	B: O.K.(rev.-04)
		GBIC module (1 on left, 0 on right in IB)
		0 O.K.(mod.-05)
		1 Not Installed
Disk backplane (0 in front, 1 in rear)
	Front Backplane: O.K.(rev.-05)
	  Temperature sensors (on front backplane)
	  0:42?C 1:42?C 2:40?C 3:39?C 4:40?C 5:40?C
	  6:43?C  (All temperatures are NORMAL.)
	Rear Backplane:  O.K.(rev.-05)
	  Temperature sensors (on rear backplane)
	  0:40?C 1:42?C 2:40?C 3:39?C 4:39?C 5:39?C
	  6:42?C  (All temperatures are NORMAL.)
Interconnect assembly
	O.K.(rev.-03)
Loop  configuration
	Loop A is configured as two separate loops.
	Loop B is configured as two separate loops.
Language        USA English


Product
Sun StorageTek A5200 Array
Sun StorageTek A5100 Array
Sun StorageTek A5000 Array

luxadm, a5x00, photon
Previously Published As
80219

Change History
Date: 2005-02-14
User Name: 31620
Action: Approved
Comment: Verified Metadata
Verified still correct for audience - free
Checked review date 2006-02-03
Checked for TM - none needed
Publishing
Version: 3
Date: 2005-02-11
User Name: 31620
Action: Accept
Comment:
Version: 0
Product_uuid
2a8acc34-0a18-11d6-87ef-bd9528a0b933|Sun StorageTek A5200 Array
2a875298-0a18-11d6-8960-b3c71159a860|Sun StorageTek A5100 Array
2a83ce34-0a18-11d6-8498-8ec5d44f476b|Sun StorageTek A5000 Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback