Sun Alert
|
Former ID
|
Synopsis
|
Last Modified Date
|
1017421.1 |
228517 |
Using Certain sccli(1M) Commands to Manage a Sun StorEdge 3510 or 3511 Fiber Channel Array May Cause the Controller to Hang |
2011-03-07
|
1001239.1 |
201662 |
Sun StorEdge 3310/3510/3511 FC Array Controllers May Incorrectly Offline Drives |
2011-03-04
|
1001199.1 |
201594 |
DRAM Parity Errors or SDRAM ECC Errors on Sun StorEdge 3310, Sun StorEdge 3510 or 3511 FC Arrays May Cause File System Integrity Issue |
2011-03-07
|
1001167.1 |
201561 |
Sun Cluster 3.x Nodes May Panic Upon Controller Failure/Replacement Within Sun StorEdge 3510/3511 Arrays |
2011-03-01
|
1001061.1 |
201388 |
Performance Degradation Reported in Controller Firmware Releases 4.1x on Sun StorEdge 3310/351x Arrays for All RAIDTypes and Certain Patterns of I/O |
2011-02-22
|
1001052.1 |
201379 |
Logical Drives May be Lost if "auto-global-spare" is Enabled |
2011-02-28
|
1000856.1 |
201137 |
Disks May be Marked as Bad Without Explanation After "Drive Failure," "Media Scan Failed" or "Clone Failed" Events |
2011-03-04
|
1000703.1 |
200921 |
Loss of Access to 3510 or 3511 FC Storage After Power Cycle of Host Using 1 Gb PCI Dual FC Host Adapter(+) HBA |
2011-03-01
|
1000681.1 |
200893 |
Failed Controller Condition May Cause Data Integrity Issues |
2010-07-22
|
1000652.1 |
200862 |
Sun StorEdge 3310/3510/3511 Disk Rebuild Operation Fails to Complete |
2011-02-24
|
1000559.1 |
200705 |
SE3310/SE3320/SE3510/SE3511 Storage Arrays May Experience Data Integrity Events |
2011-02-24
|
1000382.1 |
200504 |
Sun StorEdge 3510/3511 Arrays May Fail to Boot Upon Reset/Power Cycle When Connected in a Sun Cluster 3.x Environment With 3+ Nodes |
2011-03-07
|
1000369.1 |
200491 |
Insufficient Information for Recovery From Double Drive Failure for Sun StorEdge 33x0/35xx Arrays |
2011-03-04
|
1000318.1 |
200436 |
Sun StorEdge 3511 Array with SES Devices Using DP0554e Firmware may go Offline |
2011-03-07
|
1000314.1 |
200432 |
Sun StorEdge 3310 SCSI Array and 3510/3511 FC Array Event Hardware Failure Messages May Result in Incorrect FRU Replacement |
2011-03-01
|
1000281.1 |
200396 |
Sun StorEdge 3510/3511 Connected With LP10000 HBA May Experience I/O Interruption |
2011-02-24
|
1000192.1 |
200245 |
Logical Volumes Created With 3.27x Firmware Are Incompatible with 4.11I Firmware |
2011-03-07
|
1000018.1 |
200021 |
Recovery Behavior From Fatal Drive Failure May Lead to Data Integrity Issues |
2011-03-03
|
1000006.1 |
200007 |
Changing the Cache Optimization Mode Incorrectly on Sun StorEdge 3310, 3510 or 3511 May Cause Issues Affecting Filesystem Availability and Data Integrity |
2011-03-01
|