Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1000192.1 : Logical Volumes Created With 3.27x Firmware Are Incompatible with 4.11I Firmware
PreviouslyPublishedAs 200245 Product Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Bug Id <SUNBUG: 6274609> Date of Workaround Release 09-JUN-2005 Date of Resolved Release 30-SEP-2005 Impact When upgrading from 3.27x to 4.11I and using Logical Volumes (LV) in a Storedge 3510FC array or 3511FC array (SATA), the system will experience the following issue: data sent to the Logical Volume in the array will not destage from cache to the logical volume(s), resulting in loss of access to the array and possible loss of data. Contributing Factors This issue can occur on the following platforms:
This issue is seen immediately after the firmware upgrade from 3.27x to 4.11I. Notes:
Symptoms Following the firmware upgrade from 3.27x to 4.11I, access to the array will be lost. I/O sent to the Logical Volumes while the array was at 4.11I may be lost or corrupted. Workaround To work around the described issue, one of the two following remedies can be used (use only one of these workarounds): A) For use prior to an upgrade (recommended): Note: This is a preventative measure when using Logical Volumes on a 3510FC or 3511FC with SATA that is to be upgraded. Follow these steps:
B) If the condition already exists: Note: This procedure should be used to recover access to the array after an upgrade to 4.11I and seeing access and cache issues.
Resolution This issue is addressed on the following platforms:
Modification History Date: 30-SEP-2005 30-Sep-2005:
References<SUNPATCH: 113723-11><SUNPATCH: 113724-05> Previously Published As 101756 Internal Comments While the ability to create and manage logical volumes remains a feature of Sun StorEdge 3000 family arrays for legacy reasons, the size and performance of physical and logical drives have made the use of logical volumes obsolete. Logical volumes are unsuited to some modern configurations and do not work in those configurations. In particular, the use of logical volumes is not supported in Sun Cluster environments. Please refer to StorEdge 3000 documents for more information.
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-9086876 Internal Resolution Patches 113723-11, 113724-05 Internal Sun Alert Kasp Legacy ID 101756 Internal Sun Alert & FAB Admin Info Critical Category: Data Loss Significant Change Date: 2005-06-09, 2005-09-30 Avoidance: Patch, Workaround Responsible Manager: [email protected] Original Admin Info: [WF 30-Sep-2005, Dave M: resolution patches released, re-release as Resolved] [WF 10-Jun-2005, Dave M; customers requested clarification] [WF 09-Jun-2005, Dave M; sending for release] [WF 08-Jun-2005, Dave M; sent for 24hr review 10am] [WF 07-Jun-2005, Dave M; approved by BU, ready to send for 24hr review] [WF 07-Jun-2005, Dave M; Create Draft] Product_uuid 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array ReferencesSUNPATCH:113723-11SUNPATCH:113724-05 Attachments This solution has no attachment |
||||||||||||
|