Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1001239.1 : Sun StorEdge 3310/3510/3511 FC Array Controllers May Incorrectly Offline Drives
PreviouslyPublishedAs 201662 Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Bug Id <SUNBUG: 5007650> Date of Workaround Release 16-DEC-2004 Date of Resolved Release 30-AUG-2005 Impact During the recovery from a failure, Sun StorEdge 3310/3510/3511 FC array controllers may incorrectly offline good drives causing multiple drive failures. As a result, logical devices may become degraded thereby causing applications to stop running. Note: This issue can be triggered by a marginal link or a drive failure. Contributing Factors This issue can occur on the following platforms: SPARC Platform
Symptoms Should the described issue occur, messages similar to the following can be found in the Sun StorEdge 3310/3510/3511 event log: [1115] #16334: StorEdge Array SN#8014709 CH2 ID11: SCSI Drive ALERT: unexpected sense received (02h, 05h,21/00) The above message indicates that the drive with ID11 has rejected the command from the controller as an "illegal request". This will be followed by a message indicating that the drive has failed: [2101] #16427: LD-ID 16469417 on StorEdge Array SN#8014709: ALERT: SCSI drive failure (CH0 ID11) Note: This issue can occur on multiple drives. Workaround There is no workaround. Please see the "Resolution" section below. Resolution This issue is addressed on the following platforms: SPARC Platform
Modification History Date: 22-DEC-2004
Date: 11-FEB-2005
Date: 01-AUG-2005
Date: 30-AUG-2005
References<SUNPATCH: 113723-10><SUNPATCH: 113724-04> <SUNPATCH: 113722-10> Previously Published As 101620 Internal Comments
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected], [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-2274593, 1-1075438 Internal Resolution Patches 113723-10, 113724-04, 113722-10 Internal Sun Alert Kasp Legacy ID 101620, 57702 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Availability ==> Pervasive Significant Change Date: 2004-12-16, 2005-02-11, 2005-08-30 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: [WF 30-Aug-2005, Jeff Folla: Final patch for this issue is now available. This sun alert is resolved. Sent for release.] [WF 01-Aug-2005, Jeff Folla: Updated with available patches for the 3510 and 3511.] This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 57702 Synopsis: Sun StorEdge 3310/3510/3511 FC Array Controllers May Incorrectly Offline Drives Category: Availability Product: Sun StorEdge 3310/3510/3511 FC Array BugIDs: 5007650 Avoidance: None State: Committed Date Released: 16-Dec-2004, 11-Feb-2005 Date Closed: Date Modified: 22-Dec-2004, 11-Feb-2005 Escalation IDs: 1-2274593, 1-1075438 Pending Patches: Resolution Patches: FIN: FCO: Date Submitted: 07-Dec-2004 Submitter: [email protected] Responsible Engineer: [email protected], [email protected] Responsible Manager: [email protected] CTE group: NWS Responsible Writer: [email protected] Distribution: Preliminary-Contract SunSolve Workflow History: WF State: Issued, 11-Feb-2005, Jeff Folla WF Note: Sent for re-release per Roberta's approval. WF State: Rework, 09-Feb-2005, Jeff Folla WF Note: Updating sun alert per requested. The workaround will be removed and this will be changed back to Preliminary state. Waiting for approval before re-releasing. WF State: Issued, 22-Dec-2004, Jeff Folla WF Note: Updated impact section per submitter. WF State: Rework, 21-Dec-2004, Jeff Folla WF Note: Updating with requested changes from engineering WF State: Issued, 16-Dec-2004, Jeff Folla WF Note: Sent for release WF State: Draft, 15-Dec-2004, Jeff Folla WF Note: sent for review. WF State: Draft, 14-Dec-2004, Jeff Folla WF Note: The workaround for this issue is a point patch that is available to select customers. I sent an email asking if I should proceed with the release of this sun alert, or wait until there is a workaround available to everyone. WF State: Draft, 10-Dec-2004, Jeff Folla WF Note: Article created. Exported from KMS Creator Sat May 21 09:15:25 2005 GMT, [email protected] Internal SA-FAB Eng Submission Sun StorEdge 3310/3510/3511 FC Array Controllers May Incorrectly Offline Drives Product_uuid 3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array ReferencesSUNPATCH:113722-10SUNPATCH:113723-10 SUNPATCH:113724-04 Attachments This solution has no attachment |
||||||||||||
|