Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-77-1000703.1
Update Date:2011-03-01
Keywords:

Solution Type  Sun Alert Sure

Solution  1000703.1 :   Loss of Access to 3510 or 3511 FC Storage After Power Cycle of Host Using 1 Gb PCI Dual FC Host Adapter(+) HBA  


Related Items
  • Sun Storage 3510 FC Array
  •  
  • Sun Storage 3511 SATA Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun Alert>Criteria Category>Availability
  •  
  • GCS>Sun Microsystems>Sun Alert>Release Phase>Resolved
  •  

PreviouslyPublishedAs
200921


Product
Sun StorageTek 3510 FC Array
Sun StorageTek 3511 SATA Array

Bug Id
<SUNBUG: 6256052>

Date of Resolved Release
29-JUN-2005

Impact

After a power cycle on a host that has a Sun StorEdge 1 Gb PCI Dual FC Host Adapter(+) HBA installed, the host no longer has access to the array.


Contributing Factors

This issue can occur on the following platforms:

  • Sun StorEdge 3510 or 3511 FC array with Sun StorEdge 1GB PCI Dual FC Host Bus Adapter(+)

Symptoms

After a power cycle on the host, the storage presented by the 3510 or 3511 array will not be available to the host. This issue can be seen in the "probe-scsi-all" after the power cycle:

    Sun Ultra 60 UPA/PCI (2 X UltraSPARC-II 296MHz), No Keyboard
    OpenBoot 3.31, 768 MB memory installed, Serial #10149614.
    Ethernet address 8:0:20:9a:de:ee, Host ID: 809adeee.
    ok> probe-scsi-all
    /pci@1f,2000/SUNW,qlc@1,1     Fibre Channel link not ready - Loss of Sync     Fibre Channel link down     /pci@1f,2000/SUNW,qlc@1     Fibre Channel link not ready - Loss of Sync     Fibre Channel link down     /pci@1f,4000/SUNW,qlc@5,1     Link not ready - Loss of Sync     *********************** Local Loop Devices ***********************     No local loop devices     /pci@1f,4000/SUNW,qlc@5     Link not ready - Loss of Sync     *********************** Local Loop Devices ***********************     No local loop devices     /pci@1f,4000/scsi@3,1     /pci@1f,4000/scsi@3     Target 0      Unit 0 Disk <DISK> ST19171W SUN9.0G0776     Target 1      Unit 0 Disk <DISK> ST19171W SUN9.0G0A78     /pci@1f,4000/pci@4/SUNW,qlc@5     Fibre Channel link not ready - Loss of Sync     Fibre Channel link down     /pci@1f,4000/pci@4/SUNW,qlc@4     *********************** Local Loop Devices ***********************     Adapter loopId - 0 <<<< no 3510 but 3510 primary is on the bottom       /pci@1f,4000/pci@2/SUNW,isptwo@4

Workaround

To work around the described issue, set the data rate on the 3510 or 3511 (on the host connected channel) from AUTO to 1G. This parameter can be set in the firmware application as follows:

  1. Choose "View and Edit Channels"
  2. Click on the host channel(s) connected to the HBA
  3. For "Data Rate" choose "1G"

Resolution

Please see the "Relief/Workaround" section above for the final resolution.



Previously Published As
101758
Internal Comments


The SE3510/3511 contain a Programmable Logic Device (PLD) that controls the port bypass circuits (PBC) on all ports. The PLD also considers auto-negotiation by employing a method that attempts to determine the source transfer rate, 1Gb or 2Gb. The method does not operate correctly in all configurations when attempting to source a 1Gb transfer rate.



PCI Dual FC Host Bus Adapter(+)=Crystal + Card.


Internal Contributor/submitter
[email protected]

Internal Eng Business Unit Group
NWS (Network Storage)

Internal Eng Responsible Engineer
[email protected]

Internal Services Knowledge Engineer
[email protected]

Internal Escalation ID
1-8268699

Internal Sun Alert Kasp Legacy ID
101758

Internal Sun Alert & FAB Admin Info
Critical Category: Availability ==> Diagnosis
Significant Change Date: 2005-06-29
Avoidance: Workaround
Responsible Manager: null
Original Admin Info: [WF 29-Jun-2005, Dave M; 24hr complete, sending for release]
[WF 27-Jun-2005, Dave M; final info from submitters, approved by NWS, send for review]
[WF 08-Jun-2005, Dave M; reqested BU approval from Roberta]
[WF 07-Jun-2005, Dave M; Draft created, OKd as "Diagnosis" criteria]

Product_uuid
58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array
9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.