Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type Sun Alert Sure Solution 1001199.1 : DRAM Parity Errors or SDRAM ECC Errors on Sun StorEdge 3310, Sun StorEdge 3510 or 3511 FC Arrays May Cause File System Integrity Issue
PreviouslyPublishedAs 201594 Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3511 SATA Array Bug Id <SUNBUG: 5022022> Date of Workaround Release 03-AUG-2004 Date of Resolved Release 30-AUG-2005 Impact In some rare cases, multi-bit DRAM parity errors or multi-bit SDRAM ECC errors on Sun StorEdge 3310, Sun StorEdge 3510 or 3511 FC arrays may cause loss of file system integrity. Note: There is a very low probability for the occurrence of this issue. Contributing Factors This issue can occur on the following platforms:
This issue can occur when the controller firmware fails to distinguish between single-bit ECC errors and multi-bit ECC errors. The controller seems to continue to work normally even for multi-bit errors, which leads to loss in file system integrity. A single-bit ECC error is recoverable, while a multi-bit ECC error is not. Note: This issue may only occur when SE3310, SE3510 or SE3511 arrays encounter multi-bit DRAM parity errors or multi-bit SDRAM ECC errors. Single-bit parity or ECC errors would not encounter this issue. Symptoms Should the described issue occur, DRAM parity error messages similar to following are logged in SCCLI event log: [0104] #4287: StorEdge Array SN#xxxxxxx Controller ALERT: DRAM parity error detected SDRAM error messages similar to following are logged in "/var/adm/messages" file: Mar 19 18:30:23 SUNWscsdMonitor[628]: [ID 298706 daemon.error] [SUNWscsd 0x10B1D0D: Critical] <rctrl6003> Controller Event, SDRAM Error. Likely controller error. If error persists, replace defective controller. (Primary, Fri Mar 19 18:23:36 2004) {SN#00369b} . . Mar 20 04:21:20 SUNWscsdMonitor[628]: [ID 739865 daemon.error] [SUNWscsd 0x10B1D0D: Critical] <rctrl6003> Controller Event, SDRAM Error. Likely controller error. If error persists, replace defective controller. (Primary, Sat Mar 20 04:14:25 2004) {SN#00369b} Workaround There is no workaround for this issue. Please see the Resolution section below. Resolution This issue is addressed on the following platforms:
Modification History Date: 14-JAN-2004
Date: 30-AUG-2005 30-Aug-2005:
References<SUNPATCH: 113722-11><SUNPATCH: 113723-10> <SUNPATCH: 113724-04> Previously Published As 101542 Internal Comments
Internal Contributor/submitter [email protected] Internal Eng Business Unit Group NWS (Network Storage) Internal Eng Responsible Engineer [email protected] Internal Services Knowledge Engineer [email protected] Internal Escalation ID 1-896381 Internal Resolution Patches 113722-11, 113723-10, 113724-04 Internal Sun Alert Kasp Legacy ID 101542, 57612 (Sun Alert) Internal Sun Alert & FAB Admin Info Critical Category: Data Loss Significant Change Date: 2004-08-03, 2005-08-30 Avoidance: Patch Responsible Manager: [email protected] Original Admin Info: [WF 30-Aug-2005 Dave M: patches released, rerelase as Resolved] This document has been imported from KMS Creator and may need adjustment before re-publishing. This imported document has been reviewed/adjusted by: Review Name: Review Date: Original KMS Creator attributes below: --- PLEASE DO NOT MAKE ANY CHANGES BELOW THIS LINE! --- Sun Alert ID: 57612 Synopsis: DRAM Parity Errors or SDRAM ECC Errors on Sun StorEdge 3310, Sun StorEdge 3510 or 3511 FC Arrays May Cause File System Integrity Issue Category: Data Loss Product: Sun StorEdge 3310, Sun StorEdge 3510 FC array, Sun StorEdge 3511 FC array BugIDs: 5022022 Avoidance: Patch State: Committed Date Released: 03-Aug-2004 Date Closed: Date Modified: 14-Jan-2004 Escalation IDs: 1-896381 Pending Patches: 113727-01 Resolution Patches: FIN: FCO: Date Submitted: 29-Jul-2004 Submitter: [email protected] Responsible Engineer: [email protected] Responsible Manager: [email protected] CTE group: PTS NWS US APAC Responsible Writer: [email protected] Distribution: Contract SunSolve Workflow History: WF State: Issued, 14-Jan-2005, David Mariotto WF Note: add point patch to R/W WF State: Issued, 03-Aug-2004, David Mariotto WF Note: OKd by Anne to go. Tues, 5:45 pm (EST) WF State: Rework, 03-Aug-2004, David Mariotto WF Note: hold for High Impact Review per Anne WF State: Issued, 03-Aug-2004, David Mariotto WF Note: All approvals met, Kately notified, sent for release. WF State: Draft, 03-Aug-2004, David Mariotto WF Note: All approvals met, Kately notified, sent for release. WF State: Draft, 02-Aug-2004, David Mariotto WF Note: this will be ready to go when Baghar approves the binaries R/W. WF State: Draft, 02-Aug-2004, David Mariotto WF Note: sent approved draft to sunalert-submit alias WF State: Draft, 30-Jul-2004, David Mariotto WF Note: sending for review. WF State: Draft, 30-Jul-2004, David Mariotto WF Note: checking for final clarification, Friday 7/30 9:45am WF State: Draft, 30-Jul-2004, David Mariotto WF Note: OKd by Steve Chessin WF State: Draft, 29-Jul-2004, David Mariotto WF Note: waiting on approved pre-draft from engineering - per Katelyn Thai (see emails) (approved draft received) WF State: Draft, 29-Jul-2004, David Mariotto WF Note: Article created. Exported from KMS Creator Sat May 21 09:12:08 2005 GMT, [email protected] Internal SA-FAB Eng Submission DRAM Parity Errors or SDRAM ECC Errors on Sun StorEdge 3310, Sun StorEdge 3510 or 3511 FC Arrays May Cause File System Integrity Issue Product_uuid 3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array ReferencesSUNPATCH:113722-11SUNPATCH:113723-10 SUNPATCH:113724-04 Attachments This solution has no attachment |
||||||||||||
|