Sun SPARC Enterprise M5000 Server : Problem Documents


Problem Document Former IBIS ID Synopsis Last Modified Date
1451275.1 Sun SPARC[R] Enterprise M3000/M4000/M5000/M8000/M9000 Servers (OPL): Why FMA Events remain in the FMA history of M-Series XSCFUs 2012-09-24
1446655.1 DSCP : ipsec_check_inbound_policy: Policy Failure for the incoming packet (not secure); 2012-08-30
1393137.1 Why Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) domain not responding to sendbreak, unable to force a kernel crash dump? 2012-01-18
1381431.1 Oracle VTS may generate "Return value is -1" errors when run on M3000/M4000/M5000/M8000/M9000 platform where SPARC64 VII+ cpus are installed 2012-01-31
1361607.1 Firmware Mismatch after replacing XSCF 2011-12-09
1353452.1 Sun SPARC Enterprise Mx000 Servers: After UPS failure reports domain shuts down and does not power on 2011-09-01
1330510.1 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 Server: XSCF Email Reporting does not cover power and temperature events 2012-01-16
1328713.1 CMU Upgrade Fails with SCF-8002-LX and SCF-8002-K2 MSG-IDs 2011-06-16
1300019.1 Sun SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Server: delayed delivery of FMA mail messages from the XSCF 2012-02-09
1296435.1 Sun SPARC[TM] Enterprise M4000/M5000 - MBU_B and MEMB being faulted with SCF-8004-8X, SCF-8000-1D, and SCF-8005-MJ errors. 2012-05-17
1020968.1 268208 M4000 / M5000: SCF-8004-EC - Lost internal disks / DVD / Tape drive and voltage errors on Fan Backplane 2012-07-31
1020429.1 258248 Sun SPARC(R) Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Domain hang-up detected (POST); FMA event SCF-8005-RA 2012-07-30
1020256.1 254968 M-Series: DIMMs are suddenly marked faulty after upgrading kernel patches 2012-07-30
1019405.1 239285 SAS WWID becoming unprogrammed 2012-07-16
1019255.1 237765 Sun SPARC Enterprise M4000/M5000 Power Cord Clips not fully engaging 2012-04-04
1003550.1 204994 Sun Fire[TM] 12K - E25K / Sparc Enterprise Mx000: WARNING: fcode_timer: Timeout waiting for interpreter - Interpreter did not pick up request 2012-04-12