![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 1296435.1 : Sun SPARC[TM] Enterprise M4000/M5000 - MBU_B and MEMB being faulted with SCF-8004-8X, SCF-8000-1D, and SCF-8005-MJ errors.
In this Document
Applies to:Sun SPARC Enterprise M5000 Server - Version Not Applicable and laterSun SPARC Enterprise M4000 Server - Version Not Applicable and later Information in this document applies to any platform. SymptomsShowlogs monitor have the following errors: Jan 20 14:59:35 XSCF Warning: /UNSPECIFIED:SCF:spurious unit interrupt FMA will record these same events as: Jan 20 20:59:48.7163 051fbd14-0465-492b-aa42-6a705e31f05f SCF-8004-8X The error to note is the SCF-8000-1D which is a clock distribution error. CausePower is supplied to the MEMB and the system clock by IOU#0. SolutionContact your service provider, this is a known condition that will require replacement hardware. The FMA messages in XCP 1111 now include the IOU as a suspect component. If system is below XCP 1111 then an XCP upgrade should be scheduled. IOU#0 should be replaced by an authorized service provider. The faulted component are not faulty and should not be replaced. Use service mode to clearfault all faulted components, which should include the MBU and a MEMB. Action Plan should include a pointer to : References@<NOTE:1007101.1> - Sun SPARC(R)Enterprise M3000/M4000/M5000/M8000/M9000 (OPL) Servers: Fault clearing and LEDs behaviorAttachments This solution has no attachment |
||||||||||||||||||
|