Sun Microsystems, Inc.  Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1019255.1
Update Date:2012-04-04
Keywords:

Solution Type  Problem Resolution Sure

Solution  1019255.1 :   Sun SPARC Enterprise M4000/M5000 Power Cord Clips not fully engaging  


Related Items
  • Sun SPARC Enterprise M5000 Server
  •  
  • Sun SPARC Enterprise M4000 Server
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: Mx000
  •  
  • .Old GCS Categories>Sun Microsystems>Servers>OPL Servers
  •  

PreviouslyPublishedAs
237765


Applies to:

Sun SPARC Enterprise M4000 Server
Sun SPARC Enterprise M5000 Server
All Platforms

Symptoms

Power cord clips are not fully engaging the power cord.

Example of clip not engaged:



Example of engaged clip:

Cause

On some systems shipped prior to 1/1/2008 the clip which retains the power cord to the system chassis is not fully engaging. The potential exists for the cord to fall out when maintenance is performed.

Solution

Resolution
Tie wrap or Velcro should be used to secure the cord in place.

Examples of workaround:


For additional information on OPL Product issues see <Document 1315765.1>

Since we no longer do Change History Statements:
2009-11-02: Reviewed by Content Team member Volkmar Grote, no change

M4000, M5000, power cord loose

Attachments
This solution has no attachment
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.
 Feedback