![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1361607.1 : Firmware Mismatch after replacing XSCF
When replacing an XSCF that has a different version other than the original, a firmware mismatch error is generated. Created from <SR 3-4532707961>
Applies to:Sun SPARC Enterprise M9000-64 Server - Version: Not ApplicableSun SPARC Enterprise M5000 Server - Version: Not Applicable to Not Applicable [Release: N/A to N/A] Sun SPARC Enterprise M4000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M3000 Server - Version: Not Applicable and later [Release: N/A and later] Sun SPARC Enterprise M8000 Server - Version: Not Applicable and later [Release: N/A and later] Information in this document applies to any platform. XCP XSCF PANEL EEPROM FMEM M3000 M4000 M5000 M8000 M9000-32 M9000-64 M9000 SymptomsXCP version of Panel EEPROM and XSCF FMEM mismatched,Panel EEPROM=1061, XSCF FMEM=1092 ChangesAfter replacing a defective XSCF> a firmware mismatch can occur.Console errors generated upon login: XCP version of Panel EEPROM and XSCF FMEM mismatched, Panel EEPROM=1061, XSCF FMEM=1092 CauseThis problem was experienced when a defective XSCF> was replaced with one that had a different version of firmware.Solution1. Use the flashupdate command to try to sync the panel EEPROM and the XSCF FMEM.XSCF> flashupdate -c sync Confirm that the version is corrected. XSCF> version -c xscf If this does not correct the issue, continue to step 2. 2 Upgrade firmware. Instructions for upgrading the firmware can be found in the XSCF Users Guide. Links to current firmware can be found in Document 1002631.1 Be aware that updating from version below 1061 to a version higher than 1061 requires an interim update to 1061 first. 2. To clear a degraded / faulted component contact your Oracle Service Provider. Attachments This solution has no attachment |
||||||||||||
|