Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun ZFS Backup Appliance - Full Components List

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
System Notes:
This product is based on the Sun Fire X4470 M2 server and the Sun Disk Shelf 24x3.5" SAS-2, but uses specialized components.
Only use parts listed in the Sun ZFS Backup Appliance's Full Components List to service this product.

Array Controller
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7045305 [C] 6Gbps SAS-2 Interface Module (SIM FW 3527) n/a
NOTE: 6Gbps SAS-2 Interface Module (SIM) PN#7045305 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-3993 [C] 3V Coin Cell Battery, n/a
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0228 [F] CPU Heatsink, n/a
n/a 371-5056 [F] 2.0GHz 8-Core Xeon E7-4820 CPU Module n/a
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 530-3880 [C] RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 6M, n/a
n/a 530-3883 [C] 4X Mini SAS Cable, SFF-8088 to SFF-8088, 2M, n/a
n/a 530-4446 10Gbps QSFP to QSFP Cable, 5m, n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
X4242A 375-3696 [C] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter, n/a
n/a 530-3771 [C] RJ-45 Ethernet Cable (1m) n/a
n/a 542-0298 [C] Cluster Heartbeat Assembly n/a
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
n/a 7056175 [C] Cluster Heartbeat Assembly 542-0298 [C]
  • Cluster Heartbeat Card
n/a
  • 541-4350
  • EMI Gasket
n/a
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 511-1246 [F] 6-Slot Disk Backplane n/a
NOTE: 6-Slot Disk Backplane PN#511-1246 is used in the Sun Fire X4470 M2 as part of the Sun ZFS Backup Appliance.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1574 Disk Shelf SSD Filler Panel n/a
n/a 390-0468 Seagate ST9500530NS [ST95000NSSUN500G]
(500GB - 7200 RPM - SATA Disk)
n/a
n/a 390-0492 Seagate ST9500620NS [ST95001NSSUN500G] (500GB - 7200 RPM - SATA Disk) n/a
n/a 541-4242 Disk Shelf HDD Filler Panel, n/a
n/a 7010135 [C] 3TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST33000650SS [ST33000SSSSUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Hitachi HUS723030ALS640 [H7230AS60SUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7011094 [C] 73GB SAS Solid State Drive Assembly with 1 bracket and 1 of the following disks: n/a
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7042768 [C] 500GB - 10000 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Western Digital WD5000BLHX [WD500BLHXSUN500G] (500GB - 10000 RPM - SATA Disk)
n/a
  • Marlin 2.5" Bracket,
n/a
n/a 7047035 [C] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Stingray 3.5" Mounting Bracket
n/a
n/a 7048042 [C] 73GB SAS-2 Solid State Drive Assembly, RoHS-2013 7011094 [C]
  • 73GB Solid State Drive, SAS-2 Interface
n/a
  • Stingray 3.5" Mounting Bracket
n/a
NOTE: 500GB, 10KRPM Disk Drive Assembly PN#7042768 is used in the Sun Fire X4470 M2 as part of the Sun ZFS Backup Appliance.
NOTE: 600GB, 15KRPM Disk Drive Assembly PN#7047035 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
NOTE: 500GB, 7200RPM Disk Drive Assembly PN#542-0371 is used in the Sun Fire X4470 M2 as part of the Sun ZFS Backup Appliance.
NOTE: 3TB, 7200RPM Disk Drive Assembly PN#7010135 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
NOTE: 73GB Solid State Drive Assembly PN#7011094 and PN# 7048042 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
Ethernet
Option # Manufacturing
Part #
Description Previous
Part #
X1109A-Z 375-3617 [C] Dual 10-Gigabit Ethernet SFP+ LP, n/a
X2129A-N 530-4449 [C] 10Gbps Short Wave Pluggable Transceiver (SFP+), n/a
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-3535 [F] Fan Cage Assembly, n/a
  • 511-1243
  • Fan Board with USB and VGA,
n/a
  • 530-4349
  • Flex Circuit,
n/a
n/a 541-3539 [C] 92mm Fan Module, n/a
Fibre Channel
Option # Manufacturing
Part #
Description Previous
Part #
SG-XPCIE2FC-QF8-N 371-4325 [C] 8Gigabit/Sec PCI Express Dual FC Host Adapter, n/a
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 330-4839 Memory Slot Filler, n/a
n/a 371-5002 [C] 4GB USB 2.0 Flash Drive n/a
n/a 541-4438 [C] Memory Riser Assembly n/a
  • Memory Riser Board
n/a
n/a 7011550 [C] 16GB Memory Assembly (2 × 8GB DDR3-1333 DIMMs) n/a
  • 8GB 1.35V DDR3L-1333 DIMM
n/a
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2276 [C] 764 Watt AC Input Power/Cooling Module, n/a
n/a 300-2344 [C] Type A239C 1030/2060 Watt AC Input Power Supply n/a
n/a 7022322 [F] Power Distribution Board Assembly n/a
  • 7022323
  • Power Distribution Board
n/a
NOTE: 764W AC Input Power/Cooling Module PN#300-2276 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 180-2379 [C] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M, n/a
n/a 180-2380 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M, n/a
n/a 330-5319 1U Filler Panel n/a
n/a 350-1531 Rackmount Kit, n/a
  • n/a
  • Left Mounting Rail
n/a
  • n/a
  • Right Mounting Rail
n/a
n/a 371-3995 [F] 15KVA Three-Phase PDU, North America, n/a
n/a 371-4199 [F] 15KVA Single-Phase PDU, North America, n/a
n/a 371-4201 [F] 15KVA Single-Phase PDU, International, n/a
n/a 371-4791 [C] Tool-less Slide Rail Rack Mount Kit, n/a
n/a 371-4812 [C] Cable Management Arm, n/a
n/a 371-4976 [F] 15KVA Three-Phase PDU, International, n/a
NOTE: Rackmount Kit PN#350-1531 is used for rack mounting the Sun Disk Shelf 24x3.5" SAS-2 as part of the Sun ZFS Backup Appliance.
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3609 [C] 8-Port 6Gbps SAS-2 RAID HBA, n/a
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 7025254 [F] System Board Assembly n/a
  • 3V Coin Cell Battery,
n/a
  • 511-1245
  • Rear I/O Board,
n/a
  • System Board
n/a
  • 7012921
  • System Board Tray
n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
- 560-2951 [C] Cable Kit,
-
  • 530-4287
  • Fan Board to System Board Signal Cable,
-
  • 530-4288
  • Fan Board to System Board Power Cable,
-
  • 530-4289
  • System Board to PDB Cable,
-
  • 530-4290
  • System Board to Disk Backplane Signal Cable,
-
  • 530-4291
  • System Board to Disk Backplane Power Cable,
-
  • 530-4352
  • SFF-8087 to SFF-8087/SATA Splitter Cable, 780mm,
- 7041264 [C] Disk Shelf Chassis Assembly
-
  • 330-5203
  • Front Left End Cap,
-
  • 330-5204
  • Front Right End Cap,
-
  • 7041262
  • Centerplane Assembly
NS 341-2610 PCI Filler Panel,
NS 541-2629 2.5" Disk Drive Filler Panel,
NS 541-4348 DVD Filler Panel,
  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.