Batteries
Option # Manufacturing
Part #
Description Previous
Part #
n/a 150-3993 [F] 3V Coin Cell Battery, n/a
n/a 371-2210 1 [F] CR2032 3V Battery, n/a
1 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
CPU Module
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4887 [F] 2.26GHz Intel 6-Core Xeon L5640, 12MB, 60W, n/a
n/a 541-3310 2 [F] Xeon Heatsink w/Grease, n/a
  • 240-6751
  • Spring Screw,
n/a
  • 310-0211
  • Pre-greased Heatsink
n/a
2 Xeon Heatsink w/Grease PN#541-3310 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
Cables
Option # Manufacturing
Part #
Description Previous
Part #
n/a 350-1519 [F] Serial Cable Kit n/a
  • 530-4424
  • USB to DB9M Serial Cable,
n/a
  • 530-4425
  • DB9F to DB9F Null Modem Cable,
n/a
n/a 530-3771 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 1m, Grey, n/a
n/a 530-4403 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 2M, n/a
n/a 530-4415 [F] 4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 5M, n/a
n/a 530-4432 [F] Ethernet Cable, cat 5/5E, RJ45 to RJ45, 7' Blue, n/a
n/a 530-4433 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Red, n/a
n/a 530-4435 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Black, n/a
n/a 530-4437 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10' Orange, n/a
n/a 530-4445 [F] 10Gbps QSFP to QSFP Cable, 3m, n/a
n/a 530-4446 [F] 10Gbps QSFP to QSFP Cable, 5m, n/a
n/a 530-4502 [F] Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10-Foot, Blue, n/a
n/a 530-4567 [F] 10Gbps QSFP to QSFP Cable, 2m, n/a
n/a 560-2952 [F] X4270 M2 Cable Kit, n/a
  • 530-4245
  • 10-Pin Backplane Power Cable,
n/a
  • 530-4458
  • 24-Slot Backplane Power Cable,
n/a
  • 530-4459
  • 12/24-Slot Backplane Signal Cable,
n/a
  • 530-4471
  • Fan Signal Cable,
n/a
  • 530-4488
  • Fan Power Cable,
n/a
Communication
Option # Manufacturing
Part #
Description Previous
Part #
n/a 375-3696 [F] Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter, n/a
Disk Backplane
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4363 3 [F] 12-Slot 3.5" Disk Backplane Assembly n/a
  • 341-5083
  • Mounting Bracket,
n/a
  • 12-Slot 3.5" Disk Backplane,
n/a
3 12-Slot Disk Backplane PN#541-4363 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
Disks
Option # Manufacturing
Part #
Description Previous
Part #
n/a 542-0166 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks:, n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Coral 3.5" Disk Drive Bracket,
n/a
n/a 542-0247 4 [F] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks:, n/a
  • Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket,
n/a
n/a 542-0428 5 [F] 600GB - 15000 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: n/a
  • Seagate ST3600057SS [ST360057SSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Hitachi HUS156060VLS600 [HUS1560SCSUN600G]
    (600GB - 15000 RPM - SAS Disk),
n/a
  • Coral 3.5" Disk Drive Bracket,
n/a
n/a 7010036 6 [F] 3TB - 7200 RPM SAS Disk Assembly with 1 bracket and 2 of the following disks: n/a
  • Seagate ST33000650SS [ST33000SSSSUN3.0T] (3TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket,
n/a
n/a 7040582 [F] 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: 542-0247 7 [F]
  • Hitachi HUS723020ALS640 [H7220AS60SUN2.0T] (2TB - 7200 RPM - SAS Disk)
n/a
  • Coral 3.5" Disk Drive Bracket,
n/a
4 2TB - 7200 RPM SAS Disk Assembly PN#542-0247 is used in the Sun Fire X4270 M2 as part of the High Capacity Oracle Exadata Storage Expansion Rack X2-2.
5 600GB - 15000 RPM SAS Disk Assembly PN# 542-0428 is used in the Sun Fire X4270 M2 as part of the High Performance Oracle Exadata Storage Expansion Rack X2-2.
6 3TB - 7200 RPM SAS Disk Assembly PN# 7010036 is used in the Sun Fire X4270 M2 as part of the High Capacity Oracle Exadata Storage Expansion Rack X2-2.
7 2TB - 7200 RPM SAS Disk Assembly PN#542-0247 is used in the Sun Fire X4270 M2 as part of the High Capacity Oracle Exadata Storage Expansion Rack X2-2.
NOTE: 3TB Disk Assembly PN#7010036 requires a minimum Exadata image of 11.2.2.4.2 or later. Refer to Note 1416303.1 for more details.
NOTE: Using 2TB Disk Assembly PN#7040582 requires minimum Exadata image of 11.2.2.4.1 or later. Refer to Note 1416303.1 for more details.
NOTE: 2TB Disk Assembly PN#F542-0247 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
NOTE: 600GB Disk Assembly PN#542-0166 is required if using Exadata image 11.2.2.4.0 or earlier. Refer to Note 1416303.1 for more details.
Fan
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4124 8 [F] Fan Board Assembly, n/a
  • 330-5243
  • Fan Board Cover,
n/a
  • Fan Board,
n/a
n/a 541-4222 9 [F] Fan Assembly, n/a
  • 371-4613
  • 60×28mm 10400/9500 RPM Dual Fan,
n/a
8 Fan Board Assembly PN#541-4124 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
9 Fan Assembly PN#541-4222 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
I/O
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-2884 10 [F] x8/x8 PCI Express Riser Assembly, n/a
  • x8/x8 PCI Express Riser,
n/a
  • 541-2531
  • Bracket,
n/a
n/a 541-3356 11 [F] x8/x8 Switched PCI Express Riser Assembly, n/a
  • x8/x8 Switched PCI Express Riser,
n/a
  • 541-2531
  • Bracket,
n/a
10 x8/x8 PCI Express Riser Assembly PN#541-2884 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
11 x8/x8 Switched PCI Express Riser Assembly PN#541-3356 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
Memory
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4743 [F] 4GB USB 2.0 Flash Drive, n/a
n/a 371-4965 12 [F] 4GB Registered DDR3-1333 DIMM, 1.35V, n/a
12 4GB Memory DIMM PN#371-4965 (quantity 6) is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
Power
Option # Manufacturing
Part #
Description Previous
Part #
n/a 300-2233 13 [F] Type A247 760 Watt AC Input Power Supply, n/a
n/a 300-2235 14 [F] Type A249 1100/1200 Watt AC Input Power Supply, n/a
n/a 300-2299 [F] Type A247A 760 Watt AC Input Power Supply, 300-2233 15 [F]
n/a 300-2304 [F] Type A249A 1100/1200 Watt AC Input Power Supply 300-2235 16 [F]
n/a 541-4223 17 [F] Power Distribution Assembly, n/a
  • 341-3166
  • Bus Bar Left,
n/a
  • 341-3167
  • Bus Bar Right,
n/a
  • Horizontal Power Distribution Board,
n/a
  • 371-2484
  • PDB Signal Cable,
n/a
  • Vertical Power Distribution Board,
n/a
13 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
14 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
15 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
16 1200 Watt Power Supply, Type A249 PN#300-2235 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
17 Power Distribution Assembly PN#541-4223 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
Rack
Option # Manufacturing
Part #
Description Previous
Part #
n/a 180-2379 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M, n/a
n/a 180-2380 [F] 13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M, n/a
n/a 350-1287 [F] 1U/2U Cable Management Arm, n/a
n/a 350-1502 [F] 1U/2U Bolt-In Slide Rail Kit, n/a
n/a 350-1580 1U Vented Filler Panel n/a
n/a 350-1626 Switch Mounting rail, n/a
n/a 371-3995 [F] 15KVA Three-Phase PDU, North America, n/a
n/a 371-4000 [F] 15KVA Three-Phase PDU, International, n/a
n/a 371-4199 [F] 15KVA Single-Phase PDU, North America, n/a
n/a 371-4976 [F] 15KVA Three-Phase PDU, International, 371-4000 [F]
n/a 371-5040 [F] 22KVA Single-Phase PDU, HV n/a
n/a 371-4201 [F] [S] 15KVA Single-Phase PDU, International, n/a
SCSI
Option # Manufacturing
Part #
Description Previous
Part #
n/a 371-4982 [F] 6Gigabit SAS RAID PCI Battery Module, BBU08, n/a
n/a 375-3701 [F] 6Gigabit SAS RAID PCI Express HBA, B4 ASIC, n/a
n/a 541-4417 96GB PCI Express Flash Accelerator F20 M2 1.1 SAS HBA n/a
  • Energy Storage Module (ESM)
n/a
  • 24GB Solid State Flash Memory Module
n/a
  • PCI Express Flash Board
n/a
Switch/Hub
Option # Manufacturing
Part #
Description Previous
Part #
n/a 310-0307 [F] Cooling Fan for Cisco Catalyst 4948 Switch, n/a
n/a 371-4778 [F] ASSY, KMM, w/Japanese Keyboard & Mouse Module, n/a
n/a 371-4779 [F] Avocent MPU4032DAC-001 32-Port KVM Switch, n/a
n/a 371-4780 [F] Avocent KMM Drawer w/ US Keyboard, n/a
n/a 371-4781 [F] Avocent (DSRIQ-USB) DB15M to RJ45/USB KVM Adapter, n/a
n/a 371-4784 [F] Cisco Catalyst 4948 Switch, n/a
n/a 371-4785 [F] Power Supply for Cisco Catalyst 4948, n/a
n/a 602-4758 Data Center InfiniBand Switch 36 541-4267
  • Type A247 760 Watt AC Input Power Supply,
n/a
  • Type A247A 760 Watt AC Input Power Supply,
300-2233 19 [F]
  • 350-1312 [F]
  • Rear-to-Front Airflow Fan Module
n/a
  • 350-1566 20
  • Rear-to-Front Airflow Fan Module,
n/a
  • Sun Datacenter InfiniBand Switch 36, L
n/a
    • CR2032 3V Battery,
n/a
18 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
19 Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
20 Fan 350-1566 is not a FRU (use 350-1312).
21 CR2032 3V Battery PN#371-2210 is used in the Data Center InfiniBand Switch 36 PN#541-4267.
System Board
Option # Manufacturing
Part #
Description Previous
Part #
n/a 541-4081 [F] System Board Assembly/FRU, n/a
  • System Board,
n/a
    • 3V Coin Cell Battery,
n/a
  • 541-2543
  • System Board Tray,
n/a

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part

Exploded View

No Artwork Currently Available

Table Legend
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown

Code Manufacturing Part# Description
NS 371-2484 PDB Signal Cable,
NS 530-3892 22 [F] 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm,
NS 530-3927 [F] PDB to System Board Ribbon Cable,
NS 541-2075 [F] Bus Bar Set,
NS
  • 341-3096
  • Long Red Bus Bar,
NS
  • 341-3104
  • Short Blue Bus Bar,
NS 541-4304 23 [F] Right Indicator Panel,
NS
  • 530-4244
  • Indicator Cable,
NS
  • 530-4463
  • LED/USB Flex Cable,
NS 541-4305 24 [F] SAS Expander Assembly,
NS
  • 330-5300
  • Mounting Bracket,
NS
  • SAS Expander,
NS 541-4306 25 [F] Connector Board Assembly,
NS
  • 341-6222
  • Mounting Bracket,
NS
  • Connector Board,
NS
  • 530-3510
  • Magnetic Interlock Switch,
NS 541-4371 26 [F] Left Indicator Panel,
NS
  • 511-1594
  • LED Board,
NS
  • 530-4478
  • Left Indicator Cable,
22 4x Mini SAS/SATA Cable, SFF-8087 to SFF-8087, 670mm PN#530-3892 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
23 Right Indicator Panel PN#541-4304 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
24 SAS Expander Assembly PN#541-4305 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
25 Connector Board Assembly PN#541-4306 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
26 Left Indicator Panel PN#541-4371 is used in the Sun Fire X4270 M2 as part of the Oracle Exadata Storage Expansion Rack X2-2.
  Copyright � 2012 Sun Microsystems, Inc.  All rights reserved.