Problem Document Former IBIS ID Synopsis Last Modified Date
1352782.1 Excessive PSU temperatures on Sun Fire 4800 and E4900 servers 2011-08-29
1332034.1 Unable To Boot The Domain due to "No usable Cpu board or IO board in domain" 2011-06-23
1019667.1 243326 Sun Fire[TM] Server System Board (SB) voltage errors. 2012-08-06
1018948.1 230806 Sun Fire[TM] Serengeti: System Board power on generates "JTAG part 0x91a0: Substituting version 0x3 for version 0x4" 2010-07-06
1018832.1 230625 Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 Server ( Serengeti/Amazon ): POST fails during IOPOST, marking all I/O Boards (IBs) as bad. 2012-07-30
1018813.1 230603 Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 Server: Domains running firmware 5.15.x or later with hang-policy set to "notify" may lose critical troubleshooting data 2012-07-30
1018620.1 230316 Sun Fire [TM] Midrange Server: inaccurate msg from the SC following a reboot 2012-07-30
1018210.1 229578 Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root-No boards can be updated 2012-07-30
1017987.1 229265 Response to error: SepromSegment(constructor): PE at 0x----: Invalid CRC observed=xxxxxxxx expected=yyyyyyyy 2012-07-30
1017844.1 229081 Sun[TM] Fire 3800/4800/4810/6800/E2900/E4900/E6900/V1280 and Netra[TM] 1280/1290 Server: I/O Board (IB) power supply failures. 2012-07-30
1017808.1 229038 send break does not always work on Sun Fire[TM] platform 2012-07-30
1012439.1 217142 DR diag-level is not synced with domain boot parameters diag-level 2010-07-06
1010924.1 215073 Sun Fire[TM] Server : Dynamic Reconfiguration (DR) fails due to Real Time (RT) process running. 2012-07-30
1010922.1 215069 New US IV board were just added and the OS will not see them properly 2012-07-30
1010901.1 215041 Installation of Solaris[TM] 9 04/04 or Solaris[TM] 10 causes domain to panic or ERROR Fast Data Access MMU Miss 2012-07-30
1009954.1 213638 Sun Fire[TM] Midrange Server: Time Jumps When SC Accumulates Extended Uptime 2012-07-30
1009696.1 213337 "kstat -p" and "prtdiag -v" may give seemingly different PCI bus speeds for Dual Fast Ethernet and Dual SCSI PCI Adapters 2012-07-30
1009648.1 213283 Sun[TM] Fire 3800/4800/4810/6800/E2900/E4900/E6900/V1280 and Netra[TM] 1280/1290 Server: SepromContainer.writeOut: sun.serengeti.I2cException: verify error 2012-07-30
1009467.1 213078 How to clear faults in FMA after component replacement on Sun Fire[TM] servers. 2012-07-30
1009381.1 212971 Sun Fire[TM] E4900/E6900 server: RTS listed as "not present" in Cabinet 2012-07-30
1009358.1 212945 Pending "disabled" status being reported by "showcomponent" command 2012-07-30
1009332.1 212913 Sun Fire[TM] 3800, v1280, E2900, 4800, 4810, E4900, 6800 and E6900 and Netra 1280, 1290: Certain Memory Configurations with 5.19.0 and 5.19.1 May panic on boot with init level POST 2011-12-20
1009228.1 212768 Sun Fire [TM] SF3800/SF4800/SF4810/SF6800 - E4900/E6900 : System Serial Number(SSN) in showplatform different from SSN on the label. 2011-12-19
1009206.1 212741 How to remove unwanted aliases in NVRAM; nvunalias does not remove them from NVRAM, still show when run "devalias" 2012-07-30
1009008.1 212426 Sun Fire[TM] 3800, 4800, 4810, 6800, E4900, E6900, V1280, E2900, Netra 1280, or 1290 server: NCPQ_TO workarounds 2012-07-30
1008995.1 212411 How to recover a domain on Sun Fire[TM] 3800/4800/4810/4900/6800/6900 Midrange Server that is found in Standby mode. 2012-07-30
1008719.1 211973 Resolving Hard Hang Problems on Sun Ultra Servers 2012-05-09
1008672.1 211889 Sun Fire[TM] (3800-6800/E2900-E6900/v1280) Server: System Controller Setdate to Daylight Savings Time 2010-07-06
1007782.1 210767 Dynamic Reconfiguration or hot plug problems on a QGE HBA (4444A). 2012-10-02
1007666.1 210616 Sun Fire[TM] Servers/Solaris[TM] Operating System: CD-ROM Boot Attempt Fails With Error: "Cannot Assemble Drivers for Root" 2012-07-30
1007102.1 209793 How to reset the OpenBootProm Password on Sun Fire 3x00-6x00[TM] server 2012-07-30
1006864.1 209529 Sun Fire[TM] Mid Range and High end servers: Dynamic Reconfiguration for Uniboard removal may cause Lotus Domino server instance(s) to abnormally stop 2012-07-30
1006508.1 209106 Sun Fire[TM] V1280/E2900/3800/48x0/E4900/6800/E6900: Prtdiag and showboard display wrong cpu speed. 2012-07-30
1006505.1 209103 Best Practice for EMC Array Special LUN when connected to system running Solaris[TM] Operating System 2011-03-24
1006156.1 208621 "ERROR: Can't open boot device" booting CDROM or disk with Sun[TM] Dual FastEthernet / Dual SCSI PCI Card 2012-07-30
1005013.1 207032 probe-scsi-all may fail without reset-all on all Sun[TM] Systems 2012-07-30
1004782.1 206640 probe-scsi-all can see disks, but boot -r, devfsadm , and drvconfig, fail to add disks to OS 2012-07-30
1004679.1 206485 Sun Fire[TM] Servers: setdefaults does not reset local-mac-address? parameter 2010-10-18
1004364.1 206035 Sun Fire[TM] Midrange Server: Safari Port Error may be caused by a resetting SC 2012-01-26
1004236.1 205860 Unconfigured domains report "current year is 197x" after a reboot of the SC in 2007 2008-07-29
1004235.1 205859 Frame Manager "Service LED" is on but no failures are reported by the system 2012-05-03
1002417.1 203384 Missing drv/clone forceload in /etc/system on a system with Emulex cards may cause panic during boot 2012-07-30