![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1018210.1 : Sun Fire[TM] Midframe Server:Symptom:Flashupdate fails when user is root-No boards can be updated
PreviouslyPublishedAs 229578
Applies to:Sun Fire 4800 ServerSun Fire 4810 Server Sun Fire 3800 Server Sun Fire 6800 Server Sun Fire E4900 Server - Version: Not Applicable to Unknown Release [Release: N/A to ] All Platforms SymptomsAttempt to flashupdate the System Controller fails to upgrade firmware and simply resets the System Controller when root is used as the FTP user account. SC> flashupdate -f ftp://root:password@hostname//tmp/directory scapp rtos Causeroot is used as the FTP user account.SolutionResolution The ftp source is failing to be seen. Make sure root is either present or uncommented in the /etc/ftp/users file. Make sure that the firmware is actually at the location specified in the URL. To discuss this information further with
Oracle experts and industry peers, we encourage you to review, join or
start a discussion in an appropriate My Oracle Support Community, Oracle Sun Technologies Community.
Product Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Attachments This solution has no attachment |
||||||||||||
|