![]() | Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Problem Resolution Sure Solution 1010922.1 : New US IV board were just added and the OS will not see them properly
PreviouslyPublishedAs 215069 Symptoms The customer or FE has added new US IV boards to a machine that has US III boards already installed. The machine seems to run fine but the US IV boards are not showing up at the OS level correctly. Here is what the problem looks like: From the hardware level everything looks fine ---- **This output has been edited for easier reading ** sc0:SC> showcomponent -v Component Status Pending POST Description --------- ------ ------- ---- ----------- /N0/SB0/P0 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB0/P1 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB0/P2 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB0/P3 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB1/P0 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB1/P1 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB1/P2 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB1/P3 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB3/P0 enabled - pass UltraSPARC-IV, 1200MHz, 16M ECache /N0/SB3/P1 enabled - pass UltraSPARC-IV, 1200MHz, 16M ECache /N0/SB3/P2 enabled - pass UltraSPARC-IV, 1200MHz, 16M ECache /N0/SB3/P3 enabled - pass UltraSPARC-IV, 1200MHz, 16M ECache /N0/SB4/P0 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB4/P1 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB4/P2 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB4/P3 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB5/P2 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache /N0/SB5/P3 enabled - pass UltraSPARC-III+, 900MHz, 8M ECache From the OS however it looks like this ---- NOTICE: MP not supported on mismatched modules, booting UP only NOTICE: cpu4: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu5: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu6: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu7: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu12: cpu version 0x23 NOTICE: cpu13: cpu version 0x23 NOTICE: cpu14: cpu version 0x23 NOTICE: cpu15: cpu version 0x23 NOTICE: cpu22: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu23: SUNW,UltraSPARC-III+ version 0x21 NOTICE: cpu524: cpu version 0x23 NOTICE: cpu525: cpu version 0x23 NOTICE: cpu526: cpu version 0x23 NOTICE: cpu527: cpu version 0x23 SunOS Release 5.8 Version Generic_108528-24 64-bit Copyright 1983-2003 Sun Microsystems, Inc. All rights reserved. /kernel/drv/sparcv9/fca-pci symbol ddi_model_convert_from multiply defined System Configuration: Sun Microsystems sun4u Sun Fire 6800 System clock frequency: 150 MHz Memory size: 38912 Megabytes ========================= CPUs =============================================== Port Run E$ CPU CPU FRU Name ID MHz MB Impl. Mask ---------- ---- ---- ---- ------- ---- /N0/SB1/P0 4 900 8.0 US-III+ 2.1 /N0/SB1/P1 5 900 8.0 US-III+ 2.1 /N0/SB1/P2 6 900 8.0 US-III+ 2.1 /N0/SB1/P3 7 900 8.0 US-III+ 2.1 /N0/SB5/P2 22 900 8.0 US-III+ 2.1 /N0/SB5/P3 23 900 8.0 US-III+ 2.1 Segmentation Fault Resolution Make sure that the correct OS is installed. This particular customer was running Solaris[TM] 8 02/02 when they should have been running Solaris[TM] 8 02/04 Product Sun Fire V1280 Server Sun Fire E2900 Server Sun Fire E4900 Server Sun Fire E6900 Server Sun Fire 6800 Server Sun Fire 4810 Server Sun Fire 4800 Server Sun Fire 3800 Server Attachments This solution has no attachment |
||||||||||||
|