Sun StorEdge 3511 FC Array - Full Components List
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
|
|
Array Controller
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
XTA-3511-CTRL-1G
[S]
|
370-6773
[F]
|
RAID I/O Module, 1GB Memory and Battery Backup (370-6799) |
n/a |
n/a |
370-6774
[F]
|
Expansion I/O Module (JBOD) |
n/a |
n/a |
370-6799
[C]
|
Battery Module |
n/a |
NOTE: SFPs plug into the array controller
|
Backplane/Centerplane
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
370-6775 [F]
|
2U Chassis + Midplane |
n/a |
Cables
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
X311L Price
|
Localized Power Cord Kit - North America/Asia, |
180-1097
[C]
|
IEC 320 C13 to NEMA 5-15P - 15A/125V 2.5M Black, |
n/a |
X312L |
Localized Power Cord Kit - Continental Europe, |
180-1993
[C]
|
IEC 320 C13 to CEE 7/7 10A/250V 2.5M Black, |
n/a |
X314L |
Localized Power Cord Kit - Swiss, |
180-1994
[C]
|
IEC 320 C13 to SEV 1011 - 10A/250V 2.5M Black, |
n/a |
X317L |
Localized Power Cord Kit - U.K., |
180-1997
[C]
|
IEC 320 C13 to BS 1363 - 10A/250V 2.5M Black, |
n/a |
X383L |
Localized Power Cord Kit - Danish, |
180-1995
[C]
|
IEC 320 C13 to Asfnit 107 - 10A/250V 2.5M Black, |
530-1819
[C]
|
X384L |
Localized Power Cord Kit - Italian, |
180-1996
[C]
|
IEC 320 C13 to CEI 23-16/VII - 10A/250V 2.5M Black, |
n/a |
X386L |
Localized Power Cord Kit - Australian, |
180-1998
[C]
[S]
|
IEC 320 C13 to AS 3112 - 10A/250V 2.5M Black, |
n/a |
X9721A |
537-1036
[F]
|
Fibre Channel Optical Cable LC/SC, 0.4M |
n/a |
X9740A |
537-1062 [F]
|
Fibre Channel Optical Cable LC/LC, 100M |
n/a |
X9722A
[S]
|
537-1035
[F]
|
Fibre Channel Optical Cable LC/SC, 2M |
n/a |
X9723A
[S]
|
537-1033
[F]
|
Fibre Channel Optical Cable LC/SC, 5M |
n/a |
X9724A
[S]
|
537-1034
[F]
|
Fibre Channel Optical Cable LC/SC, 15M |
n/a |
X9730A
[S]
|
537-1057 [F]
|
Fibre Channel Optical Cable LC/LC, 0.8M |
n/a |
X9732A
[S]
|
537-1041
[F]
|
Fibre Channel Optical Cable LC/LC, 2M, 2.0M |
n/a |
X9733A
[S]
|
537-1042
[F]
|
Fibre Channel Optical Cable LC/LC, 5M |
n/a |
X9734A
[S]
|
537-1043
[F]
|
Fibre Channel Optical Cable LC/LC, 15M |
n/a |
X9735A
[S]
|
537-1053
[F]
|
Fibre Channel Optical Cable LC/SC, 25M |
n/a |
X9736A
[S]
|
537-1051
[F]
|
Fibre Channel Optical Cable LC/LC, 25M |
n/a |
X9737A
[S]
|
537-1055
[F]
|
Fibre Channel Optical Cable LC/SC, 50M |
n/a |
X9738A
[S]
|
537-1052
[F]
|
Fibre Channel Optical Cable LC/LC, 50M |
n/a |
X9739A
[S]
|
537-1063 [F]
|
Fibre Channel Optical Cable SC/SC, 100M |
n/a |
n/a |
130-4723
[F]
|
Fibre Channel Cable Coupler SC/SC |
n/a |
n/a |
370-5540 [F]
|
Fibre Channel Expansion Cable, 0.5M |
n/a |
n/a |
370-6627 [F]
|
DB-9M to DB-9F Serial Cable, 1.8M |
n/a |
n/a |
370-6629 [F]
|
Ethernet Cable, 35-88730002 |
n/a |
n/a |
530-1819
[C]
|
Localized Power Cord Kit - Danish |
n/a |
NOTE: SFPs plug into the array controller
|
Disks
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
XTA-ST1NC-400G7K |
540-6364 [F]
|
400GB - 7200 RPM SATA, Disk Assembly with one of the following disks: |
n/a |
|
- Hitachi HDS724040KLSA80 [HDS7240SBSUN400G]
(400GB - 7200 RPM - SATA Disk)
|
n/a |
XTA-ST1NC-250G7K
[S]
|
540-6180 [F]
|
250GB - 7200 RPM SATA, Disk Assembly with one of the following disks: |
n/a |
|
- Hitachi HDS722525VLSA80 [HDS7225SASUN250G]
(250GB - 7200 RPM - SATA Disk)
|
n/a |
|
- Hitachi HDT722525DLA380 [HDS7225SBSUN250G]
(250GB - 7200 RPM - SATA Disk)
|
n/a |
|
- Hitachi HDT725025VLA380 [HDS7225SCSUN250G]
(250GB - 7200 RPM - SATA Disk)
|
n/a |
XTA-ST1NC-500G7K
[S]
|
540-6365 [F]
|
500GB - 7200 RPM SATA, Disk Assembly with one of the following disks, |
n/a |
|
- Hitachi HDS725050KLA360 [HDS7250SASUN500G]
(500GB - 7200 RPM - SATA Disk)
|
n/a |
n/a |
n/a |
Drive Mounting Bracket, 82-00001200 (Manufacturer Part Number) |
n/a |
Fibre Channel
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XPCI1FC-QF4 Price
|
375-3354
|
4Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI2FC-QF4 Price
|
375-3294
|
4Gb PCI-X Dual FC Host Adapter, |
n/a |
SG-XPCIE1FC-EM4 Price
|
375-3396
|
4Gigabit/Sec PCI Express Single FC Host Adapter, |
n/a |
SG-XPCIE1FC-QF4 Price
|
375-3355
|
4Gigabit/Sec PCI Express Single FC Host Adapter, |
n/a |
SG-XPCIE2FC-EM4 Price
|
375-3397
|
4Gigabit/Sec PCI Express Dual FC Host Adapter, |
n/a |
SG-XPCIE2FC-QF4 Price
|
375-3356
|
4Gigabit/Sec PCI Express Dual FC Host Adapter, |
n/a |
SG-XPCIE2FCGBE-E-Z Price
|
371-4018
|
4Gb/sec PCI Express Dual FC / Dual Gigabit Ethernet ExpressModule Host Adapter, Emulex, |
n/a |
SG-XPCIE2FCGBE-Q-Z Price
|
371-4017
|
4Gb/sec PCI Express Dual FC / Dual Gigabit Ethernet ExpressModule Host Adapter, QLogic, |
n/a |
X6748A |
375-0118
|
Compact PCI (cPCI) Dual Channel FC |
n/a |
(X)5133A
[S]
|
501-6640
|
Fibre Channel PCI Adapter |
n/a |
SFP-SW-4GB 1
[S]
|
371-0294
[F]
|
4Gbps Short Wave SFP, |
n/a |
SFP-SW-4GB-4PK 2
[S]
|
371-0294
[F]
|
4Gbps Short Wave SFP, |
n/a |
SG-XPCI1FC-EM2
[S]
|
375-3304
|
2Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI1FC-JF2
[S]
|
375-3156
|
JNI 2Gb PCI Single FC Host Adapter |
n/a |
SG-XPCI1FC-QF2 3
[S]
|
375-3102
|
2Gb PCI Single FC Host Adapter |
n/a |
SG-XPCI1FC-QL2
[S]
|
375-3383
|
2Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI1FC-QLC
[S]
|
375-3253
|
Entry-Level 2Gb PCI-X Single FC Host Adapter |
n/a |
SG-XPCI1FC-QLC-Z
[S]
|
375-3364
|
Entry-Level 2Gb PCI-X Single FC Host Adapter, |
n/a |
SG-XPCI2FC-EM2
[S]
|
375-3305
|
2Gb PCI-X Dual FC Host Adapter, |
n/a |
SG-XPCI2FC-JF2
[S]
|
375-3157
|
JNI 2Gb PCI Dual FC Host Adapter |
n/a |
SG-XPCI2FC-QF2 4
[S]
|
375-3108
|
2Gb PCI/PCI-X Dual FC Host Adapter |
n/a |
|
|
n/a |
SG-XPCI2FC-QF2-Z
[S]
|
375-3363
|
2Gb PCI/PCI-X Dual FC Host Adapter, |
n/a |
|
|
n/a |
X6727A
[S]
|
375-3030
|
PCI Dual FC Host Adapter+, L |
n/a |
X6757A
[S]
|
375-3048
|
SBus Dual FC Network Adapter |
n/a |
X6799A
[S]
|
375-3019
5
|
PCI Single FC Host Adapter |
n/a |
X9279A
[S]
|
370-6697
|
2Gb/Sec Single FC PCI-X Host Adapter |
n/a |
n/a |
370-5211
[F]
|
2Gbps Short Wave SFP |
n/a |
n/a |
371-0099
[F]
|
2Gbps Short Wave SFP |
n/a |
1 This x-option is a Small Form Pluggable shortwave Fibre Channel optical transceiver capable of 4Gb, 2Gb, and 1Gb transfer rates.
2 The x-option is a 4 pack of Small Form Pluggable shortwave Fibre Channel optical transceivers capable of 4Gb, 2Gb, and 1Gb transfer rates.
3 Support of this HBA is provided for Red Hat AS 2.1 and 3.0, and for Solaris x86 9 Update 6, using Qlogic's native driver.
4 Support of this HBA is provided for Red Hat AS 2.1 and 3.0, and for Solaris x86 9 Update 6, using Qlogic's native driver.
5 375-3019 with SC connector is no longer available. The substitute adapter uses a smaller LC connector.
NOTE: AThe SG-(X)PCI1FC-EM2 and SG-(X)PCI2FC-EM2 HBA will not support private loop topology configurations.
NOTE: Direct attachment of a host bus adapter (HBA) to the Expansion I/O Module (JBOD) is not supported.
NOTE: For FRU/CRU status, see host system's Full Components List.
|
Power
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
XTA-3000-2UAC-KIT
[S]
|
370-6776
[F]
|
AC Power Supply / Fan Module, 2U |
n/a |
371-0108
[F]
|
420 Watt AC Input Power Supply, L |
n/a |
XTA-3000-2UDC-KIT
[S]
|
370-6798
[F]
|
DC Power Supply / Fan Module, 2U |
n/a |
371-0109
[F]
|
420 Watt DC Input Power Supply, L |
n/a |
Rack
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
XTA-3000-2U-R2T |
370-7596 |
Sun StorEdge 3000 2U Rack Ready to Tabletop conversion kit |
n/a |
XTA-3000-2URK-19C |
370-5649 |
Telco Rackmount Kit, Center Mount, 2U, 19" Wide |
n/a |
XTA-3000-2URK-19F |
370-5650 |
Telco Rackmount Kit, Flush/Front Mount, 2U, 19" Wide |
n/a |
XTA-3000-2URK-19U |
370-6166 |
SE3000 2U Family Universal Rackmount Kit |
n/a |
XTA-3000-2URK-19CZ
[S]
|
371-0828 |
Telco Rackmount Kit, Center Mount, 2U, 19" Wide, L |
n/a |
XTA-3000-2URK-19FZ
[S]
|
371-0829 |
Telco Rackmount Kit, Flush/Front Mount, 2U, 19" Wide, L |
n/a |
XTA-3000-2URK-19UZ
[S]
|
371-0827 |
SE3000 2U Family Universal Rackmount Kit, L |
n/a |
Switch/Hub
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
SG-XSW64-BASE |
370-5790
|
64 Port Base Unit 2Gb FC Switch (32 ports included with base unit) |
n/a |
SG-XSWBRO24K-MOD |
Brocade 24000 Director 16-port FC Switching Blade |
370-6820
[F]
|
16-Port Switch Module |
n/a |
SG-XSWM6140-64P |
370-6131
|
McData Intrepid 6140 140-port Switch with 64 Ports active |
n/a |
SG-XSWM6140-RK64I |
370-6133
|
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (International power) |
n/a |
SG-XSWM6140-RK64P |
370-6132
|
McData Intrepid 6140 140-port Switch with 64 ports active in a McData Fabricenter Rack (US power). |
n/a |
SG-XSWMD4500-8P |
370-6085
|
McData Sphereon 4500 24-port Switch with 8 ports activated |
n/a |
SG-XSWMD4500-UPG |
n/a |
McData Sphereon 4500 8 port activation license key, activates 8 additional ports |
n/a |
SG-XSWQLG5200-20P |
370-7694 6
|
QLogic 5200 Switch (20 ports active) |
n/a |
SG-XSWQLG5200-8P |
370-7664
[F]
|
QLogic 5200 Switch (8 ports active)
|
n/a |
SG-XSW16-2GB
[S]
|
540-5404
[F]
|
Sun StorEdge Network 2GB FC Switch-16 |
n/a |
SG-XSW16-32P
[S]
|
540-4751
[F]
|
Sun StorEdge Network FC Switch-16 |
n/a |
SG-XSW64-BLADE-8P
[S]
|
370-5847
[F]
|
8 Port 2Gb FC Blade (Add up to 4 to SG-XSW64-BASE to achieve 64 ports) |
n/a |
SG-XSW8-2GB
[S]
|
540-5554
[F]
|
Sun StorEdge Network 2GB FC Switch-8 |
n/a |
SG-XSWBRO12000-32P
[S]
|
370-5748
|
Brocade Silkworm 12000 Switch with 32 Ports |
n/a |
SG-XSWBRO12000-64P
[S]
|
370-4749
|
Brocade Silkworm 12000 Switch with 64 Ports |
n/a |
SG-XSWBRO24K-32P
[S]
|
370-6820
[F]
|
16-Port Switch Module |
n/a |
370-7046
|
Brocade 24000 Director 32-Port Switch |
n/a |
SG-XSWBRO3200
[S]
|
370-5769
[F]
|
Brocade Silkworm 3200 8-Port FC Switch |
n/a |
SG-XSWBRO3250
[S]
|
370-6824
[F]
|
Brocade 3252 Value Line 8-Port FC Switch |
n/a |
370-7047
|
Brocade 3250 8-Port FC Switch |
n/a |
SG-XSWBRO3250VL2
[S]
|
370-6824
[F]
|
Brocade 3252 Value Line 8-Port FC Switch |
n/a |
SG-XSWBRO3800
[S]
|
370-4949
[F]
[S]
|
Brocade Silkworm 3800 16-Port FC Switch |
n/a |
SG-XSWBRO3850
[S]
|
370-6826
[F]
|
Brocade 3852 Value Line 16-Port FC Switch |
n/a |
370-7048
|
Brocade 3850 16-Port FC Switch |
n/a |
SG-XSWBRO3850VL2
[S]
|
370-6826
[F]
|
Brocade 3852 Value Line 16-Port FC Switch |
n/a |
SG-XSWBRO3900
[S]
|
370-6078
[F]
|
Brocade Silkworm 3900 32-Port FC Switch |
n/a |
SG-XSWBRO4100-16P
[S]
|
370-7756
[F]
|
Brocade Silkworm 4100 FC Switch (16 Ports) |
n/a |
SG-XSWBRO4100-32P
[S]
|
370-7770
|
Brocade Silkworm 4100 FC Switch (32 Ports) |
n/a |
SG-XSWMD4300-12P
[S]
|
370-6169
[F]
|
McData Sphereon 4300 12-port Switch |
n/a |
SG-XSWMD6064-32P
[S]
|
370-5732
|
McData 6064 Director Switch w/32 ports |
n/a |
n/a |
540-4372
[F]
|
StorEdge Network FC Switch-8 |
n/a |
6 Sixteen 2-Gb ports and four 10-Gb ports activated.
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown
|
Code |
Manufacturing Part# |
Description |
NS |
370-6007 |
Air Management Blank Sled, Disk Drive Slot Filler (Option XTA-3000-AMBS) |
NS |
370-7589 [F]
|
LED/Reset Switch Board |
- |
|
- LED/Reset Switch Board, L
|
NS |
371-0718 [F]
|
2U SE3000 L/R Plastic Ear (for chassis) |
NS |
n/a |
DB-9M to DB-25M Adapter, 35-00000109 |
NS |
n/a |
Power Cord Clamp, 82-00000829 |
NS |
n/a |
Front Bezel Key, 82-00000909 |
|