Some documentation links included on this page may contain "A5000" in the title, but they were included because the contents of these documents are also relevant and applicable to the A5200 array.
   
    |  FIN | 
     
       Impl. 
     | 
    Components 
      Affected | 
    Description | 
  
  
    | I0897-1 | 
    
       R 
     | 
    Sun StorEdge A5200 | 
    Under specific conditions, addresses for disks in a StorEdge A5200
array may display incorrectly with the 'format' command.  Instead of
appearing as "c#t#d#", a disk address will display as "c#td#". | 
  
  
    | I0854-1 | 
    
       C 
     | 
    Sun Fire V880 
                    Sun StorEdge A5200 | 
    After removing an FC-Al disk from either the internal disk sub-system
of a V880 or from an A5X00.  As a result of the disks have been under
the control of Veritas Volume Manager 3.2, An 'Invalid device
structure' error message can be seen.  This causes the replacement of
the disks to fail.  When this happens, a reboot is needed at this point
to correct affected devices.  Having to reboot the system nullifies
disk hotswap a valuable RAS feature. | 
  
   
    | I0836-1 | 
     
       R 
     | 
    Seagate ST336752FC 36.4GB 
      Disk  
      36GB 15K 1-in FC W/SLED DRV ASSY (540-5178-01) 
      36GB 15K 1-in FC W/SLED DRV ASSY (540-5179-01) 
      DRV SEA 36GB 15K 1-in FCAL (390-0099-02) 
      DRV SEA 36GB 15K 1-in FCAL T3 (390-0101-02) | 
    Seagate ST336752FC (36.4GB) 
      disk drives should not be installed into non-RAID configurations. Seagate 
      ST336752FC (36GB) disk drives should only be installed into configurations 
      which use Veritas Volume Manager or SDS RAID software, or hardware RAID 
      configurations. | 
  
   
    | I0816-1 | 
     
       C 
     | 
    Seagate 36GB disk (540-4525-01), Seagate 73GB disk (540-4905-01) | 
    Seagate ST336605FC 36GB and ST373405FC 73G drives could be 
      susceptible to label corruption. | 
  
   
    | I0791-1 | 
     
       R 
     | 
    Brocade 16-port 2Gb switch 
      (370-4949-01) 
      Brocade 16-port switch (370-4396-01) 
      Brocade 8-port switch (370-4395-01) | 
    This FIN will explain the field 
      procedure for the installation of Brocade 8 and 16 port switches into a 
      Sun rack. There is no downtime and little customer impact as a result of 
      this issue. | 
  
   
    | I0777-1 | 
     
       R 
     | 
    SBus Dual FC Network Adapter 
      (375-3048-01)  
      SBus I/O Board with SOC+ (501-4266-08) 
      I/O Board with SOC+ (501-4833-01) 
      Graphics I/O Board with SOC+ (501-4884-07)  
      FC-AL SBus Card (FC100/S) (501-5202-03) 
      FC-AL SBus Card (FC100/S) (501-5266-04)  
      A3500FC FC-AL Array Ctrlr w/Memory (540-4026-01)  | 
    In some configurations, after 
      a Fibre Channel (FC) loop disruption such as a system reboot or a plugging/unplugging 
      of the FC cable at the FC hub, the SOC+ HBA might intermittently take the 
      FC loop down. Also, it is possible that a LIP (Loop Initialization Primitive) 
      received on an idle port of a SOC+ HBA can disrupt I/O activity on the second 
      port of that HBA. | 
  
   
    | I0741-1 | 
     
       C 
     | 
    11-Slot FC-AL Disk Backplane 
      (501-4158-04)  | 
    When replacing either disk, 
      R10 or F10, in slot 10 of an StorEdge A5200 array, a large amount of OFFLINE/ONLINE 
      conditions occur and all disks of the A5200 become inaccessible. When the 
      disk is re-inserted the connectivity is back but time consuming maintenance 
      procedures are necessary. | 
  
   
    | I0712-1 | 
     
       R 
     | 
    FC-AL GBIC Module 100MB/s 
      (option X6731A, 370-2303) | 
    This FIN is to inform the 
      field of a new style GBIC that will be shipping with A5X00 Storage Arrays. 
      Installing a FINISAR GBIC in any platform other than A5X00 will result in 
      a restricted access condition which may result in unanticipated downtime. 
     | 
  
   
    | I0711-1 | 
     
       R 
     | 
    16-PORT Python Switch (370-4276-01) 
     | 
    Some StorEdge Network FC Switch-16 
      units were assembled and shipped from the vendor with their mounting brackets 
      reversed. This could potentially result in these switches being installed 
      backwards in the 72-inch StorEdge Expansion Cabinet. This improper installation 
      may cause the inlet temperature of the switch to exceed its recommended 
      range and this could affect the performance and the life of the switch. 
      In addition, the connecting fibre cables might be damaged by hitting the 
      rear cabinet door and may require replacement. | 
  
   
    | I0704-1 | 
     
       R 
     | 
    OEM Module GBIC Ancor (370-2303-03) 
      8-port swtch Brocade Silkworm 2400 (370-4395-01) 
      16-port swtch Brocade Silkworm 2800 (370-4396-01) 
      IBM GBIC (370-3975-01) 
      Finisar GBIC (370-4379-01) | 
     
       Sun Professional Services is selling Brocade Silkworm Switches containing 
        GBIC's which have no Sun label or part number. This FIN will provide guidance 
        for replacing these non-Sun GBIC's in the case of failure. All Brocade 
        Silkworm switches that are re-sold through Sun Professional Services (PS) 
        will contain IBM or Finisar GBIC's without Sun part numbers, which are 
        identical to the short wave GBIC's that Sun currently sells and supports. 
        The Brocade switches themselves will have a Sun part number (370-4395-01 
        or 370-4396-01) and a serial number label, but the GBIC's in the switches 
        may not have a Sun part number. The non-Sun GBICs will be labeled as follows: 
      
         
          | Vendor | 
          FAB Markings  | 
         
         
          | IBM | 
          IBM42S10LNNAA20 | 
         
         
          | Finisar  | 
          FTR-8519  | 
         
       
     | 
  
   
    | I0701-1 | 
     
       R 
     | 
    Instant Image 2.0 
      Fast Write Cache 2.0 | 
    The Fast Write Cache 2.0 and 
      Instant Image 2.0 states that the products will work with Java versions 
      1.2.1 and higher. This is not the case. For installations without Component 
      Manager 2.1, Java versions 1.2.1_04a through 1.2.2_05a are the only versions 
      of Java that will work with Instant Image 2.0 and Fast Write Cache 2.0. 
      If Component Manager 2.1 is installed, then Java 1.2.2 is the only version 
      of Java that will work. Java 1.3 does not work at all with these products. 
     | 
  
   
    | I0700-1 | 
     
       R 
     | 
    FC Switch-16 (370-4276) 
      FC Switch-8 (370-4035) 
      FC Switch-8 Assy (540-4372)  
      FC Switch-16 Assy (540-4751) | 
    StorEdge Network FC Switch-8 
      and StorEdge Network FC Switch-16 products installed in a Storage Area Network 
      (SAN) configuration must have the proper level of firmware installed for 
      proper operation. All switches in the SAN must contain matching firmware 
      versions. Failure to verify and install the correct switch firmware when 
      installing or replacing switches in a SAN can cause the switch to fail. 
      It is important that the firmware of existing switches in a SAN and any 
      replacement switch be checked for compatibility when installing a new switch 
      into the SAN configuration. | 
  
   
    | I0653-1 | 
     
       R 
     | 
    RSM array shelves (370-2343) | 
    RSM Array shelves may collapse 
      under weights greater than 40lbs (18.2kg), causing system damage or personal 
      injury.  | 
  
   
    | I0647-1 | 
     
       R 
     | 
    FC-AL SBus Card (FC100/S 501-3060-06) 
      FC-AL SBus Card (FC100/S 501-5202-03) 
      FC-AL SBus Card (FC100/S 501-5266-04)  | 
     
       Fcode upgrade instructions for the FC100/S Host Adapter supplied with 
        the following luxadm patches can lead to obsolete fcode being installed. 
       
      
         105310-14 
          SunOS 5.5.1: Patch for socal, sf driver, and luxadm  
         105375-25 
          SunOS 5.6: sf & socal driver patch  
         107473-06 
          SunOS 5.7: luxadm patch  
         109529-03 
          SunOS 5.8: luxadm, liba5k and libg_fc patch  
       
      The latest fcode for the FC100/S Host Adapter has been moved to patch 
         109400-03 
        for all versions of Solaris. This change is not reflected in the README 
        files of the luxadm patches currently available ( 105310, 
         105375, 
         107473 
        and  109529). 
        These patches still provide a lower version of the FC100/S fcode (1.11) 
        and give instructions for installing it.  
     | 
  
   
    | I0645-1 | 
     
       C 
     | 
     Seagate ST318203FC 
      (18.2GB - 10000 RPM 
      FC-AL 540-4191-01) 
      Seagate ST318304FC 
      (18.2GB 10000 RPM 
      FC-AL 540-4440-01) 
      Seagate ST336704FC 
      (36.4GB 10000 RPM 
      FC-AL 540-4525-01) 
      Seagate ST136403FC 
      (36.4GB 10000 RPM 
      FC-AL 540-4367-01)  
      Seagate ST318304FC 
      (18.2GB 10000 RPM 
      FC-AL 540-4673-01) 
     | 
     
       Seagate ST318304FC and ST336704FC drives will not boot and will not be 
        recognized by host systems running Solaris 2.5.1, 2.6, and early versions 
        of 7 (prior to 11/99) without the correct version of the sf driver patch 
        being installed.  
      These new generation drives were released as second source 18GB and 36GB 
        FC-AL disk drives. These drives are meant to be interchangeable with older 
        generation Seagate drives. The FRU part number for the old and new drives 
        is the same.  
      
         
          | FRU | 
          Capacity | 
          Old Drive | 
          New Drive | 
         
         
          | 540-4191-02 | 
          18GB | 
          ST318203FC | 
          ST318304FC | 
         
         
          | 540-4440-01 | 
          18GB | 
          ST318203FC | 
          ST318304FC | 
         
         
          | 540-4673-01 | 
          18GB | 
          ST318203FC | 
          ST318304FC | 
         
         
          | 540-4192-01 | 
          36GB | 
          ST136403FC | 
          ST336704FC | 
         
         
          | 540-4367-01 | 
          36GB | 
          ST136403FC | 
          ST336704FC | 
         
       
     | 
  
   
    | I0630-1 | 
     
       R 
     | 
    A5x00 Arrays 
      T3 Arrays | 
    Fiber channel devices may 
      experience symptoms consistent with marginal signal quality on the GBaud 
      FC-AL loops. Marginal signal quality can be caused by dust particles and/or 
      errant electrostatic discharge (ESD) for GBIC's, backplanes, interface boards, 
      interconnect assemblies, FC-AL drives, and fiber cables. 
      Symptoms of errors that might be seen include: 
       excessive "CRC Error" or "scsi 
      parity error" messages 
       excessive "OFFLINE" messages 
       excessive "timeout" messages 
       "Offline Timeout" messages 
     | 
  
   
    | I0575-1 | 
     
       R 
     | 
    Sun StorEdge Component Manager 
      2.0 (798-2832-01) | 
    When used on a heavily loaded 
      system to monitor multiple enclosures, Component Manager response time can 
      be longer than expected. | 
  
   
    | I0554-1 | 
     
       R 
     | 
    Veritas Volume Manager for 
      Solaris Version 3.0.2 (798-2205-01) | 
    There is confusion with regard 
      to supporting the A5x00 products with hubs attached and the use of Volume 
      Manager version 3.0.2. This confusion came from the Veritas Volume Manager 
      Hardware Application Note Release 3.0.2, which states on page 12...  
       
      "Dynamic Multi Pathing (DMP) does not support hub-attached A5000,  
      A5100, and A5200 arrays at this time. See your sales representatives  
      for details about DMP support plans for this configuration."  
      If the above recommendation is not followed, then the system could encounter 
      catastrophic results. | 
  
   
    | I0541-2 | 
     
       R 
     | 
    FC100/P FC-AL PCI Card (375-0040) | 
     
       Any FC-AL PCI loop where A5X00 Storage Arrays are directly connected 
        to i) a host using PCI FC100/P initiator card without hub, or ii) other 
        host (dual host) with FC-AL initiator-card is connected to the same loop 
        may experience the following errors as described in BugId 4243157.  
        Sample error messages:  
         
        Dec 8 05:18:17 name unix: transport rejected (-2)  
        Dec 8 05:18:17 name unix:  
        Dec 8 05:18:17 name unix: WARNING: /pci@4,4000/SUNW,  
        ifp@4/ssd@w2100002037141659,0 (ssd32)  
        Dec 8 05:18:17 name unix: transport rejected (-2)  
        Dec 8 05:18:17 name unix:  
        Dec 8 05:18:18 name unix: ifp0: LIP occurred  
        Dec 8 05:18:18 name unix: ifp0: Loop up  
        Dec 8 05:18:18 name unix: ifp0: Loop reconfigure in progress  
        Dec 8 05:18:18 name unix: ifp0: Loop reconfigure done  
        Dec 8 08:17:41 name unix: ifp0: Loop down  
        Dec 8 08:17:46 name unix: ifp0: LIP reset occurred  
      UPDATE FOR FIN I0541-2: 
      The Corrective Action on FIN I0541-1 provides two different options or 
        solutions to the above mentioned problems as follows:  
      
        - OPTION-1: The FC100/P card is the only Initiator on any one loop where 
          Sun A5x00 Storage Array are direct connected. 
 
        - OPTION-2: A Sun FCAL hub is placed between the FC100/P card(s), and 
          the A5X00 Storage Array. In this case, more than one host-adapter on 
          the same loop, may be used.
 
       
      Due to resistance from the Field over the cost of implementation, OPTION-2 
        has been removed from the Corrective Action. This option would have required 
        the customer to purchase and connect a hub to the A5x00 Storage Array. 
        The Corrective Action now recommends only OPTION-1 for avoiding this FC100/P 
        card problem. This restriction is advantageous from high-availability/RAS 
        point of view since having each host on a separate loop removes a single 
        point Of failure (SPOF) in Multi Initiator configurations.  
     | 
  
   
    | I0533-1 | 
     
       R 
     | 
    Seagate ST39102FC (9GB 10000 
      RPM FC-AL 540-3869) | 
    A failure mechanism has been 
      identified as low amplitude head failures due to scratches across the Pole 
      Tip of the head. Pole Tip is the electrical area of the head which detects 
      the magnetic signal from the disk.  
      The most frequent symptoms are error messages similar to below: 
      
        -  Drive not ready and/or drive has excessive G-list adds
 
       
     | 
  
  I0520-1 | 
   
     C 
   | 
  A5x00 | 
  Swapping a disk within a clustered 
    environment could cause issue for a customer's clustered environment in the 
    future if the disk is the quorum device. 
    Failure to notice that the failed disk is the quorum device and swapping it 
    will cause the cluster to invoke manual intervention if the cluster goes into 
    failure fencing or split brained activities. | 
  
   
    | I0506-1 | 
     
       R 
     | 
    72" rack | 
    There is confusion in the 
      field about a 2" clearance requirement on the left side only (viewing from 
      the front of the cabinet) of the 72" Storage Expansion Cabinet. This clearance 
      is not required for all cabinet configurations, only those containing A5x00 
      Storage Arrays and/or E4x00 Enterprise Servers. | 
  
   
    | I0502-1 | 
     
       R 
     | 
    370-2303-01 GBIC 
      370-2303-03 GBIC 
      370-3975-01 GBIC | 
    The Factory phased in shipments 
      of -03 GBICS beginning early April 1999. A5X00s with chassis s/n greater 
      than 9917 will have the -03 GBIC, or an IBM -02 CD GBIC. These modules appear 
      physically identical to the -02 modules. Field personnel cannot differentiate 
      between module revisions without physically removing them to read the revision 
      level on the connector label. This would require an unacceptable maintenance 
      downtime for host systems.The Vixel -03 Vertical cavity GBICS can be identified 
      as follows: 
      
        -  Parts are marked as a -03; this marking can be found on the GBIC 
          connector (system interface connector) as "03a" for -03 revision a.
 
        -  The inside if the cable connector housing will be silver in color 
          on the Vixel vertical cavity (-03) parts; black on the -02 cd laser 
          versions.
 
       
     | 
  
   
    | I0501-1 | 
     
       R 
     | 
    11 slot backplane 501-4158 | 
    The revision level printed 
      on the labels for the 7-slot Backplane and the 11-slot Backplane for the 
      A5000, A5100, and A5200 array are different than the revision levels that 
      are dynamically reported by the arrays. | 
  
   
    |  I0400-2 | 
     
       R 
     | 
    Seagate ST29102FC (9.1GB 10000 
      RPM FC-AL 540-3869) 
      Seagate ST39103FC (9.1GB 10000 RPM FC-AL 540-3869) 
      Seagate ST318203FC (18.2GB 10000 RPM FC-AL 540-4191) | 
     Empty backplane/incorrect 
      configuration on StorEdge A5x00 can Cause Errors. This minimum configuration 
      is a requirement because circuitry on the disk drives regenerate and retime 
      the data signals which corrects signal quality loss accumulated through 
      the bypass circuitry between empty slots. Empty backplanes can generate 
      errors which are intermittent and difficult to isolate.  
      Error message examples:  
       
      Jun 6 20:48:11 depth unix: sf0: Target 0x12 Reset Failed. Ret=105  
      Jun 6 20:48:11 depth unix: sf0: sf_reset all  
      Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.5010] socal0: port 0:  
      Fibre Channel is OFFLINE  
      Jun 6 20:48:11 depth unix: WARNING:  
      /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d4c,0 (ssd8):  
      Jun 6 20:48:11 depth unix: SCSI transport failed: reason 'timeout':  
      retrying command  
      Jun 6 20:48:11 depth unix: ID[SUNWssa.socal.link.6010] socal0: port 0:  
      Fibre Channel Loop is ONLINE  
      Jun 6 20:48:13 depth unix: sf0: ELS 0x0 to target 0x1d retrying  
      Jun 6 21:00:07 depth unix: WARNING:  
      /sbus@1f,0/SUNW,socal@0,0/sf@0,0/ssd@w2100002037070d5a,0 (ssd5):  
      Jun 6 21:00:07 depth unix: Error for Command: read(10) Error Level:  
      Retryable  |