FAB Implementation Synopsis Last Modified Date
A0222-1 U Seagate Cheetah 4 FCAL and SCSI disk drives may experience higher than expected failure rate. Jan 04 2006
A0212-1 U New xoptions installed in Delorean 72-inch Racks may not power up due to faulty power cords Jul 15 2003
A0199-2 C Seagate Cheetah 3 FCAL disk drives in A5x00 and T3 Storage Arrays may experience higher than expected failure rate. Sep 02 2003
A0183-1 C Sun Storage T3 Power Cooling Unit Battery Packs may experience early life failures. Jan 22 2002
A0175-1 C Sun StorEdge T3 (Purple) Array pre-GA units have the potential of experiencing intermittent parity or `no cache found' errors. Apr 11 2001
I0837-1 R Sun Fire 15K servers cannot boot from Sun StorEdge T3/T3+ Arrays due to an issue with the Sun FCP SCSI Device Driver 2002-06-14
I0836-1 R Seagate ST336752FC (36.4GB)) disk drives should not be installed into non-RAID configurations 2002-06-11
I0824-1 R Disk drives in some Sun StorEdge T3/T3+ Arrays may be difficult to remove due to sticking drive latches 2002-06-10
I0777-1 R In some configurations, after a FC loop disruption the SOC+ HBA intermittently takes the FC loop down 2002-02-25
I0745-1 R T3/T3+ Power Control Unit connectors on the midplane may be damaged by excessive vibration during shipment or operation 2002-03-25
I0712-1 R Finisar GBIC problems on the storage array products 2001-08-29
I0711-1 R The problem with Incorrectly mounted brackets on the switch 2001-10-10
I0704-1 R Field handling procedure on non-Sun supported GBICs 2001-09-18
I0700-1 R FC Switch f/w level must be checked to install or replace StorEdge Network FC Switch into a SAN Config. 2001-07-27
I0691-1 R New disk drive initialization problem if replaced failed disk drive 2001-07-30
I0674-1 R Confusing syslog error messages may cause to replace good T3 Power Cooling Unit) 2001-05-10
I0667-2 C Sun StorEdge T3 and T3+ array controllers which are connected to a public ethernet network may disable without warning or experience availability problems if they are scanned by third party security software 2002-03-07
I0631-1 R StorEdge T3 controller insertion problem 2001-01-05
I0630-1 R Problem with mishandling a fiber optical device 2001-03-30
I0629-1 n/a T3 Array display with using DM with VxVM 2000-12-14
I0625-1 R T3 Diagnostics Cable 2001-01-19
I0606-1 R Off-line diagnostic test on Sun StorEdge T3 partner pairs may inadvertently put the units into a reboot loop which may require a power-cycle to break out of the loop 2000-10-26
I0575-1 R When used on a heavily loaded system to monitor multiple enclosures, Component Manager response time can be longer than expected. 2000-04-27