A0222-1 |
U
|
Seagate Cheetah 4 FCAL and SCSI disk drives may experience higher than expected failure rate. |
Jan 04 2006
|
A0212-1 |
U
|
New xoptions installed in Delorean 72-inch Racks may not power up due to faulty power cords |
Jul 15 2003
|
A0199-2 |
C
|
Seagate Cheetah 3 FCAL disk drives in A5x00 and T3 Storage Arrays may experience higher than expected failure rate. |
Sep 02 2003
|
A0183-1 |
C
|
Sun Storage T3 Power Cooling Unit Battery Packs may experience early life failures. |
Jan 22 2002
|
A0175-1 |
C
|
Sun StorEdge T3 (Purple) Array pre-GA units have the potential of experiencing intermittent parity or `no cache found' errors. |
Apr 11 2001
|
I0837-1 |
R
|
Sun Fire 15K servers cannot boot from Sun StorEdge T3/T3+ Arrays due to an issue with the Sun FCP SCSI Device Driver |
2002-06-14
|
I0836-1 |
R
|
Seagate ST336752FC (36.4GB)) disk drives should not be installed into non-RAID configurations |
2002-06-11
|
I0824-1 |
R
|
Disk drives in some Sun StorEdge T3/T3+ Arrays may be difficult to remove due to sticking drive latches |
2002-06-10
|
I0777-1 |
R
|
In some configurations, after a FC loop disruption the SOC+ HBA intermittently takes the FC loop down |
2002-02-25
|
I0745-1 |
R
|
T3/T3+ Power Control Unit connectors on the midplane may be damaged by excessive vibration during shipment or operation |
2002-03-25
|
I0712-1 |
R
|
Finisar GBIC problems on the storage array products |
2001-08-29
|
I0711-1 |
R
|
The problem with Incorrectly mounted brackets on the switch |
2001-10-10
|
I0704-1 |
R
|
Field handling procedure on non-Sun supported GBICs |
2001-09-18
|
I0700-1 |
R
|
FC Switch f/w level must be checked to install or replace StorEdge Network FC Switch into a SAN Config. |
2001-07-27
|
I0691-1 |
R
|
New disk drive initialization problem if replaced failed disk drive |
2001-07-30
|
I0674-1 |
R
|
Confusing syslog error messages may cause to replace good T3 Power Cooling Unit) |
2001-05-10
|
I0667-2 |
C |
Sun StorEdge T3 and T3+ array controllers which are connected to a public ethernet network may disable without warning or experience availability problems if they are scanned by third party security software |
2002-03-07
|
I0631-1 |
R
|
StorEdge T3 controller insertion problem |
2001-01-05
|
I0630-1 |
R
|
Problem with mishandling a fiber optical device |
2001-03-30
|
I0629-1 |
n/a
|
T3 Array display with using DM with VxVM |
2000-12-14
|
I0625-1 |
R
|
T3 Diagnostics Cable |
2001-01-19
|
I0606-1 |
R
|
Off-line diagnostic test on Sun StorEdge T3 partner pairs may inadvertently put the units into a reboot loop which may require a power-cycle to break out of the loop |
2000-10-26
|
I0575-1 |
R
|
When used on a heavily loaded system to monitor multiple enclosures, Component Manager response time can be longer than expected. |
2000-04-27
|