Oracle Exalogic Elastic Cloud X2-2 - Full Components List
|
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
|
System Notes: |
This product is based on the Sun Fire X4170 M2, Sun ZFS Storage 7320, and Disk Shelf 24x3.5" SAS-2 but uses specialized components.
Only use parts listed in the Exalogic Elastic Cloud X2-2 Full Components List to service this product.
|
|
Batteries
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
371-2210
[F]
|
CR2032 3V Battery, |
n/a |
CPU Module
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
371-4885
[F]
|
2.4GHz Intel Quad-Core Xeon E5620, 12MB, 80W, |
n/a |
n/a |
371-4889
[F]
|
2.93GHz Intel 6-Core Xeon X5670, 12MB, 95W, |
n/a |
n/a |
541-2545 [F]
|
Xeon Heatsink, |
n/a |
|
|
n/a |
|
|
n/a |
NOTE: 2.4GHz Intel Quad-Core Xeon E5620 PN#371-4885 is used in the Sun ZFS Storage 7320 as part of the Oracle Exalogic X2-2.
NOTE: 2.93GHz Intel 6-Core Xeon X5670 PN#371-4889 is used in the Sun Fire X4170 M2 as part of the Oracle Exlogic X2-2.
|
Cables
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
350-1519 [F]
|
Serial Cable Kit |
n/a |
|
- USB to DB9M Serial Cable,
|
n/a |
|
- DB9F to DB9F Null Modem Cable,
|
n/a |
n/a |
530-3771 [F]
|
RJ-45 Ethernet Cable (1m), |
n/a |
n/a |
530-3880 [F]
|
RJ45 to RJ45 Shielded Ethernet Cable, CAT5, 6M, |
n/a |
n/a |
530-3883 [F]
|
4X Mini SAS Cable, SFF-8088 to SFF-8088, 2M, |
n/a |
n/a |
530-4402 [F]
|
4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 1M, |
n/a |
n/a |
530-4403 [F]
|
4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 2M, |
n/a |
n/a |
530-4404 [F]
|
4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 3M, |
n/a |
n/a |
530-4415 [F]
|
4x QSFP 4x QSFP Copper QDR InfiniBand Cable, 5M, |
n/a |
n/a |
530-4432 [F]
|
Ethernet Cable, cat 5/5E, RJ45 to RJ45, 7' Blue, |
n/a |
n/a |
530-4436 [F]
|
Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7' Black, |
n/a |
n/a |
530-4502 [F]
|
Ethernet Cable, Category 5/5E, RJ45 to RJ45, 10-Foot, Blue, |
n/a |
n/a |
530-4526 [F]
|
Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7-Foot, Green, |
n/a |
n/a |
530-4527 [F]
|
Ethernet Cable, Category 5/5E, RJ45 to RJ45, 7-Foot, Yellow, |
n/a |
NOTE: PN#530-3883 is used to connect the Sun ZFS Storage 7320 to the Disk Shelf 24x3.5" SAS-2.
|
Communication
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
375-3606
[F]
|
Sun Dual Port 40Gb/sec 4x Infiniband QDR Host Channel Adapter PCI Express |
n/a |
n/a |
375-3696
[F]
|
Dual 40Gbps InfiniBand 4x QDR PCI Express Low Profile Host Channel Adapter, |
n/a |
n/a |
511-1496
[F]
|
Cluster Heartbeat Card |
n/a |
Disk Backplane
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
511-1548
[F]
|
8-Slot Disk Backplane, SATA DVD, |
n/a |
Disks
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
350-1574 |
Disk Shelf SSD Filler Panel |
n/a |
n/a |
540-7841 [F]
|
32GB Solid State Drive SATA Assembly |
n/a |
|
- 32GB Solid State Drive, SATA Interface,
|
n/a |
|
|
n/a |
n/a |
541-4242 |
Disk Shelf HDD Filler Panel, |
n/a |
n/a |
542-0274 [F]
|
2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks: |
n/a |
|
- Seagate ST32000444SS [ST32000SSSUN2.0T] (2TB - 7200 RPM - SAS Disk)
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
n/a |
542-0330 [F]
|
512GB Solid State Drive SATA-2 Assembly |
n/a |
|
- Toshiba THNS512GG8BB (512GB Solid State Drive), SATA-2 Interface,
|
n/a |
|
|
n/a |
n/a |
542-0371 [F]
|
500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks:, |
n/a |
|
- Seagate ST9500530NS [ST95000NSSUN500G]
(500GB - 7200 RPM - SATA Disk)
|
n/a |
|
- Seagate ST9500620NS [ST95001NSSUN500G]
(500GB - 7200 RPM - SATA Disk)
|
n/a |
|
|
n/a |
n/a |
7015705 |
18GB SAS Solid State Drive Assembly {PKG} |
F542-0286 |
|
- 18GB SAS Solid State Drive Assembly
|
542-0286
[F]
|
|
- 18GB SAS Solid State Drive,
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
n/a |
F542-0286 |
18GB SAS Solid State Drive Assembly |
n/a |
|
- 18GB SAS Solid State Drive Assembly
|
n/a |
|
- 18GB SAS Solid State Drive,
|
n/a |
|
- Stingray Mounting Bracket
|
n/a |
NOTE: 500GB - 7200 RPM SATA Disk Assembly with 1 bracket and 1 of the following disks PN#542-0371 is used in the Sun ZFS Storage 7320 as part of the Oracle Exalogic X2-2.
NOTE: PN#350-1574 and PN#541-4242 are used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
NOTE: 2TB - 7200 RPM SAS Disk Assembly with 1 bracket and 1 of the following disks PN#542-0274 is used in the Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
NOTE: 32GB Solid State Drive Assembly PN#540-78641 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
NOTE: 18GB SAS Solid State Drive Assembly PN# 7015704 and PN#542-0286 are used in the Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
NOTE: 512GB Solid State Drive Assembly PN#542-0330 is used in the Sun ZFS Storage 7320 as part of the Oracle Exalogic X2-2.
|
Ethernet
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
135-1204
|
10Gbps QDR Ethernet QSFP Transceiver, |
n/a |
n/a |
375-3481
[F]
|
PCI Express Quad Gigabit Ethernet UTP, |
n/a |
n/a |
375-3617
[F]
|
Dual 10-Gigabit Ethernet SFP+ LP, |
n/a |
n/a |
530-4449
[F]
|
10Gbps Short Wave Pluggable Transceiver (SFP+), |
n/a |
Fan
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-4274 [F]
|
Fan Board Assembly, |
n/a |
|
|
n/a |
|
|
n/a |
n/a |
541-4276 [F]
|
Fan Module, |
n/a |
|
|
n/a |
I/O
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-2883 [F]
|
1-Slot x8 PCI Express Riser Assembly, |
n/a |
|
- 1-Slot x8 PCI Express Riser,
|
n/a |
|
|
n/a |
n/a |
541-2885 [F]
|
1-Slot x16 PCI Express Riser Assembly, |
n/a |
|
- 1-Slot x16 PCI Express Riser,
|
n/a |
|
|
n/a |
Memory
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
371-4743 [F]
|
4GB USB 2.0 Flash Drive, |
n/a |
n/a |
371-4898
[F]
|
4GB Registered DDR3-1333 DIMM, 1.5V, |
n/a |
n/a |
371-4966
[F]
|
8GB Registered DDR3-1333 DIMM, 1.35V, |
n/a |
NOTE: 8GB Registered DDR3-1333 DIMM PN#371-4966 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
NOTE: 4GB Registered DDR3-1333 DIMM PN#371-4898 is used in the Sun ZFS Storage 7320 as part of the Oracle Exalogic X2-2.
|
Power
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
300-2143
[F]
|
760 Watt Power Supply, |
n/a |
n/a |
300-2233
[F]
|
760 Watt AC Power Supply, Type A247, |
300-2143
[F]
|
n/a |
300-2276
[F]
|
764W AC Input Power Supply and Fan Assembly, |
n/a |
n/a |
511-1489
[F]
|
Power Distribution Board, |
n/a |
NOTE: 764W AC Input Power Supply and Fan Assembly PN#300-2276 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
NOTE: Power Supplies 300-2143 and 300-2233 are also used in the Data Center InfiniBand Switch 36 541-4267.
NOTE: 760 Watt Power Supply PN#300-2233 is also used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
NOTE: Power Distribution Board PN#501-1489 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
|
Rack
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
180-2379 [F]
|
13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 1M, |
n/a |
n/a |
180-2380 [F]
|
13A/250V 90° IEC 320 Sheet E to IEC 320 C13 Cord, 2M, |
n/a |
n/a |
350-1521 [F]
|
1U Vented Filler Panel |
n/a |
n/a |
350-1531 |
Rackmount Kit, |
n/a |
|
|
n/a |
|
|
n/a |
n/a |
350-1546 [F]
|
Cable Management Arm 1U, |
n/a |
n/a |
350-1626 |
Switch Mounting rail, |
n/a |
n/a |
371-3995
[F]
|
15KVA Three-Phase PDU, North America, |
n/a |
n/a |
371-4000
[F]
|
15KVA Three-Phase PDU, International, |
n/a |
n/a |
371-4001
[F]
|
24KVA Three-Phase PDU, International, |
n/a |
n/a |
371-4199
[F]
|
15KVA Single-Phase PDU, North America, |
n/a |
n/a |
371-4201
[F]
|
15KVA Single-Phase PDU, International, |
n/a |
n/a |
371-4510
[F]
|
24KVA Three-Phase PDU, North America, |
n/a |
n/a |
371-4919 [F]
|
Screw-Mount Slide Rail Kit, |
n/a |
n/a |
371-4976
[F]
|
15KVA Three-Phase PDU, International, |
371-4000
[F]
|
n/a |
371-4977
[F]
|
24KVA Three-Phase PDU, International, |
n/a |
NOTE: Rackmount Kit PN#350-1531 is used for rack mounting the Sun Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
|
Removable Media
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-2732 [F]
|
USB Assembly, |
n/a |
|
|
n/a |
|
|
n/a |
|
|
n/a |
NOTE: USB Assembly PN#541-2732 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
|
SCSI
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
371-4982 [F]
|
6Gigabit SAS RAID PCI Battery Module, BBU08, |
n/a |
n/a |
375-3609
[F]
|
8-Port 6Gbps SAS-2 RAID HBA, |
n/a |
n/a |
375-3647
[F]
|
6Gbps SAS-2 RAID Expansion Module (REM), B2/B4 ASIC, |
n/a |
Switch/Hub
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
310-0307 [F]
|
Cooling Fan for Cisco Catalyst 4948 Switch, |
n/a |
n/a |
371-4784
[F]
|
Cisco Catalyst 4948 Switch, |
n/a |
n/a |
371-4785
[F]
|
Power Supply for Cisco Catalyst 4948, |
n/a |
n/a |
541-4267 |
Data Center InfiniBand Switch 36, L |
n/a |
|
|
n/a |
|
- 760 Watt AC Power Supply, Type A247,
|
300-2143
[F]
|
|
- Fan Module for Sun Datacenter InfiniBand Switch 36,
|
n/a |
|
- Sun Datacenter InfiniBand Switch 36, L
|
n/a |
|
|
n/a |
n/a |
541-4269 |
Network QDR Infiniband Gateway Switch |
n/a |
|
|
n/a |
|
- 760 Watt AC Power Supply, Type A247,
|
300-2143
[F]
|
|
- Fan Module for Sun Datacenter InfiniBand Switch 36,
|
n/a |
|
|
n/a |
|
- InfiniBand Gateway Switch
|
n/a |
System Board
|
Option # |
Manufacturing Part # |
Description |
Previous Part # |
n/a |
541-4081 [F]
|
System Board Assembly/FRU, |
n/a |
|
|
n/a |
|
- Panasonic BR2032 Battery,
|
n/a |
|
|
n/a |
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
|
No Artwork Currently Available
Table Legend |
[F] = Field Replaceable Unit (FRU)
[C] = Customer Replaceable Unit (CRU)
[S] = Supported, but can no longer be ordered with this system
[N] = No longer supported for this system
Price = Price this Part
NS = Not Shown
|
Code |
Manufacturing Part# |
Description |
NS |
350-1288
|
DIMM Slot Filler, |
NS |
530-3927 [F]
|
PDB to System Board Ribbon Cable, |
NS |
530-4228 [F]
|
SFF8087 to SFF8087 Cable, 690mm, |
NS |
530-4417 [F]
|
6-Pin Fan Power Cable, |
NS |
530-4431 [F]
|
Fan Data Ribbon Cable, |
NS |
540-7980 [F]
|
Disk Shelf Chassis Assembly/FRU, |
NS |
|
|
NS |
|
|
NS |
|
|
NS |
541-2075 [F]
|
Bus Bar Set, |
NS |
|
|
NS |
|
|
NS |
541-2629 |
Disk Drive Filler Panel, |
NS |
541-2636 [F]
|
Lightpipe Assembly, |
NS |
|
- Right Side Endcap Lightpipe,
|
NS |
|
- Left Side Endcap Lightpipe Assembly,
|
NS |
|
|
NS |
|
|
NS |
|
|
NS |
541-4275 [F]
|
Connector Board, |
NOTE: Lightpipe Assembly PN#541-2636 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2-2.
NOTE: Disk Shelf Chassis Assembly PN#540-7980 is used in the Sun Disk Shelf 24x3.5" SAS-2 as part of the Oracle Exalogic X2-2.
NOTE: Connector Board Assembly PN#541-4275 is used in the Sun Fire X4170 M2 as part of the Oracle Exalogic X2.
|
|