Sun StorEdge[tm] 6320 System: Repair Procedures

The Sun StorEdge 6320 contains Sun StorEdge 6020 Arrays and a Sun Fire[tm] V100 Service Processor within its cabinet. The repair procedures for the Sun StorEdge 6320 is provided in the following manual:

Sun StorEdge 6320 System 1.0 Reference and Service Manual

The table below provides the section and page number that each procedure begins on.

For hardware repair procedures specific to the Sun StorEdge 6020 Arrays and Sun Fire V100 Service Processor, please refer to the Repair Procedures page for each:

Sun Fire V100: Repair Procedures

Sun StorEdge 6020/6120: Repair Procedures

Component
Section / Page Number
Tips
6020 Arrays
12-1 to 12-15
  • Minimum supported releases for the Sun StorageTek T3+, 6120, 6320 and 6920. (FAB 1000061.1).
  • Early versions of StorADE health monitoring software may misrepresent disk errors from Sun StorEdge 3910/3960 and 6910/6960 Arrays and Sun StorEdge 6320 Systems. (FAB 1001189.1).
  • The Sun StorEdge 6320 Restore CD fails to restore the system from flash disk. (FIN I1158-1).
  • See Sun StorEdge 6020 and 6120 Arrays System Manual (817-0200), Chapter 6 for detailed information.
  • StorEdge 6320 Systems with MIRE 1.2.3.1 Service Processor software will not complete an "unconfigure" operation. (FIN I1146-1).
  • 'logadm' on the SE6320 image is not restarting syslogd resulting in missed log messages and false positive StorADE alarms. (FIN I1143-1).
  • StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may experience downtime or data integrity if double disk errors or back-end loop hangs occur. (FIN I1125-1).
  • Sun StorEdge 6120 Arrays and 6320 Systems may reset due to a Controller Board SRAM timing issue (FIN I1043-2).
  • During power on (cold boot), one or more drives may come up in an offline state (FIN I1009-2).
AC Power Cable
9-3 to 9-5
 
Adding a Second Cabinet
9-8
 
Cable Labels
A-1 to A-10
 
Disk Drive
 
  • Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected outages due to a spindle motor issue (FIN I1136-1).
  • Seagate Cheetah 7 146GB FC-AL and 73 GB FC-AL disk drives may experience higher than expected failure rates due to spindle motor failure (FCO A0256-1).
Ethernet Hub
10-1 to 10-6
 
FC Switches
11-1 to 11-3
 
Front Door
7-2
 
Key Switch
9-5 to 9-7
 
Power Sequencer
9-1 to 9-3
 
Side Panel
7-3
 
SAN Multiplatform Support
This site, Sun Storage Networking provides information as follows:
  • Multi-Platform Support Documents
  • Get the Software

 