Sun StorEdge[tm] 6320 System: Repair Procedures
The Sun StorEdge 6320 contains Sun StorEdge 6020 Arrays and a
Sun Fire[tm] V100 Service Processor within its cabinet. The repair procedures
for the Sun StorEdge 6320 is provided in the following manual:
Sun StorEdge
6320 System 1.0 Reference and Service Manual
The table below provides the section and page number that each procedure begins
on.
For hardware repair procedures specific to the Sun StorEdge 6020 Arrays and
Sun Fire V100 Service Processor, please refer to the Repair Procedures page
for each:
Sun Fire V100: Repair Procedures
Sun StorEdge 6020/6120: Repair Procedures
Component
|
Section / Page Number
|
Tips
|
6020 Arrays |
12-1 to 12-15
|
-
Minimum supported releases for the Sun StorageTek T3+, 6120, 6320 and 6920.
(FAB 1000061.1).
-
Early versions of StorADE health monitoring software may misrepresent disk errors from Sun
StorEdge 3910/3960 and 6910/6960 Arrays and Sun StorEdge 6320 Systems.
(FAB 1001189.1).
-
The Sun StorEdge 6320 Restore CD fails to restore the system
from flash disk. (FIN I1158-1).
- See Sun StorEdge 6020
and 6120 Arrays System Manual (817-0200), Chapter 6 for detailed
information.
-
StorEdge 6320 Systems with MIRE 1.2.3.1 Service Processor
software will not complete an "unconfigure" operation. (FIN I1146-1).
-
'logadm' on the SE6320 image is not restarting syslogd resulting
in missed log messages and false positive StorADE alarms. (FIN I1143-1).
-
StorEdge 6120 and 6320 Arrays with firmware prior to 3.1.x may
experience downtime or data integrity if double disk errors or
back-end loop hangs occur. (FIN I1125-1).
- Sun StorEdge 6120 Arrays and 6320 Systems may reset due to a Controller
Board SRAM timing issue (FIN I1043-2).
- During power on (cold boot), one or more drives may come up in an
offline state (FIN I1009-2).
|
AC Power Cable |
9-3 to 9-5
|
|
Adding a Second Cabinet |
9-8
|
 
|
Cable Labels |
A-1 to A-10
|
|
Disk Drive
|
|
-
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected
outages due to a spindle motor issue (FIN I1136-1).
- Seagate Cheetah 7 146GB FC-AL and 73 GB FC-AL disk drives
may experience higher than expected failure rates due to
spindle motor failure (FCO A0256-1).
|
Ethernet Hub |
10-1 to 10-6
|
|
FC Switches |
11-1 to 11-3
|
|
Front Door |
7-2
|
|
Key Switch |
9-5 to 9-7
|
|
Power Sequencer |
9-1 to 9-3
|
|
Side Panel |
7-3
|
|
SAN Multiplatform Support
|
This site, Sun Storage Networking provides information as follows:
- Multi-Platform Support Documents
- Get the Software
|
|