Sun StorEdge[tm] 3510 FC Array: Repair Procedures
This section provides tips (when available) for the most common
repair procedures for the StorEdge 3510. The repair procedures are provided
in the following manual:
Component
|
Tips
|
Disk Drive & Sled
|
-
Improved firmware for Seagate 10K.6 disk drives will reduce the incidence of unexpected
outages due to a spindle motor issue (FIN I1136-1).
- SCSI Timeout Values may be set too low resulting in intermittent timeouts
due to arbitration, retries, or bad block reallocation (FIN I1058-1).
- Seagate Cheetah 7 146GB FC-AL and 73 GB FC-AL disk drives
may experience higher than expected failure rates due to
spindle motor failure (FCO A0256-1).
- Seagate Cheetah 7 FC-AL and SCSI disk drives with serial numbers below 60000 are experiencing a higher
than expected failure rate due to a spindle motor issue (FCO A0239-1).
- Issues with Sun StorEdge 3510 FC controller and JBOD FC cables may result in Amber LED for controllers or drives.
(FCO A0237-2)
|
I/O Contoller Modules
|
- Sun StorEdge 3310/3510/3511 controllers must be allowed to complete the firmware cross loading process
during controller replacement.
(FAB 1017358.1).
- Write performance and specifically Sequential write for Sun
StorEdge 3310, 3510, 3511 Storage Array is diminishing when
both controllers are installed
(FIN I1150-1).
- Fix for battery expiration issue of Sun StorEdge 3510 is now available through new SCCLI (1.6.2)
(FIN I1078-1).
- New 3.27R firmware for Sun StorEdge 3510 FC Array provides
enhanced CLI capabilities and functionality with StorADE (FIN I1078-1
).
- A small number of Sun StorEdge 3510 FC Array Controller FRUs may contain
defective firmware (FIN I0953-1).
- Issues with Sun StorEdge 3510 FC controller and JBOD
FC cables may result in Amber LED for controllers or drives.
(FCO A0237-2)
|
SAN Multiplatform Support
|
This site, Sun Storage Networking provides information as follows:
- Multi-Platform Support Documents
- Get the Software
|
|