Document Audience: | INTERNAL |
Document ID: | A0237-2 |
Title: | Issues with Sun StorEdge 3510 FC controller and JBOD FC cables may result in Amber LED for controllers or drives. |
Copyright Notice: | Copyright © 2007 Sun Microsystems, Inc. All Rights Reserved |
Update Date: | Thu Jul 29 00:00:00 MDT 2004 |
----------------------------------------------------------------------------
- Sun Proprietary/Confidential: Internal Use Only -
----------------------------------------------------------------------------
FIELD CHANGE ORDER
(For Authorized Distribution by Enterprise Services)
FCO #: A0237-2
Status: inactive
Synopsis: Issues with Sun StorEdge 3510 FC controller and JBOD FC cables may result in Amber LED for controllers or drives.Date: Jul/29/04
SunAlert: No
Top FIN/FCO Report: Yes
Products Reference: Sun StorEdge 3510 FC Array
Product Category: Storage / Array
Product Affected:
Systems Affected:
Mkt_ID Platform Model Description
------ -------- ----- -----------
- SE3510 All Sun StorEdge 3510 FC Array
X-Options Affected:
Mkt_ID Platform Model Description
------ -------- ----- -----------
N/A
PARTS AFFECTED:
Part Number Description
----------- -----------
370-5540-02 FC Jumper/Expansion Cable
370-5537-04(Or Less) Sun StorEdge 3510 Raid I/O Module
540-6098-xx Drive 73GB 15K RPM FC-AL
540-5628-xx Drive 36GB 15K RPM FC-AL
540-5626-xx Drive 146GB 10K RPM FC-AL
540-5629-xx Drive 73GB 10K RPM FC-AL
References:
ECOs: WO_28832, WO_28720
LEAP: 2562 (for controller)
LEAP: 2563 (for cable)
PatchID: 113723-07, 113729-01
FIN: I1078-1
BugID: 5012640
Issue Description:
Change History
--------------
A0237-2 Date Modified: Jul/29/2004
Updates: ISSUE DESCRIPTION and CORRECTIVE ACTION
. ISSUE DESCRIPTION: Modified information in Affected Controllers
and Affected Cable sections.
. CORRECTIVE ACTION: added specific replacement part number information
are added additional sections.
A0237-2 Date Modified: Jul/14/2004
Updates: SPECIAL CONSIDERATION
. SPECIAL CONSIDERATION: added last sentence about scheduled work
A0237-2 Date Modified: Jun/28/2004
Updates: IMPLEMENTATION, REFERENCES, DESCRIPTION, SPECIAL CONSIDERATION,
and CORRECTIVE ACTION.
. IMPLEMENTATION: The implementation is now MANDATORY
. REFERENCES: Added patch 113729-01
. DESCRIPTION: Added Customer Letter and Customer List
. SPECIAL CONSIDERATION: new information see below
. CORRECTIVE ACTION: all new Corrective Action, see below
--------------------------------------------------------------------------
A small percentage of Sun StorEdge 3510 FC controllers may fail with Amber LED
which is due to a marginal component and/or marginal JBOD FC cables.
These marginal controllers and/or marginal JBOD FC cables may also cause drives
to fail with Amber LED.
An internal only link to the customer list identifying the affected systems
can be viewed via the below "Internal Only" URL;
http://sdpsweb.central/FIN_FCO/FCO/FCO_A0237-1_Dir/Customer_List.sxc
To assist the field in a communication of this issue to customers, a Customer
Letter is provided via the below "Internal Only" URL;
http://sdpsweb.central/FIN_FCO/FCO/FCO_A0237-1_Dir/Customer_Letter.sxw
(Note: the Customer Letter and Customer List above are in the A0237-1
directory but are just applicable to this release of A0237-2)
Affected Controllers
--------------------
This issue results in the following message in the event log/terminal
console:
Wed Feb 18 10:13:31 2004
[0111] #4: StorEdge Array SN#8002658 Controller ALERT: redundant
controller failure detected
The following Sun StorEdge 3510 FC controllers are affected:
370-5537-04 (Revision 04/50) or earlier
Note: 370-5537-05 (Revision 05/50) is not affected by this issue however if
firmware 3.27R (or above) is not installed then it could have a similar failure
(see Bug 5012640).
Controller part numbers and revisions are shown on the bar code label on the
controller faceplate. Use the link below for label detail:
http://webhome.sfbay/minnow_eng/3510_ctr_label.gif
Affected Cables
---------------
For StorEdge 3510 configurations that have JBOD(s) connected, the controller
failure message (shown above) and Amber LED can also be a result of potential
mating issues between the connector and the JBOD/jumper FC cables.
The following JBOD FC Cables are affected:
370-5540-02 (TCC 35-0000118-005A)
The jumper/expansion cable manufacturer (TCC or BIZ) is on the label affixed to
the cable. Use the link below for label detail:
http://webhome.sfbay/minnow_eng/TCC_cable.gif
Affected Disk Drives
--------------------
Sun StorEdge 3510 FC disk drives may incorrectly be failed with an Amber LED
due to affected controllers and/or affected cables (see above).
Typical drive failure indication include drive amber LED and similar messages
shown below in the event log:
Fri Jan 2 06:54:04 2004
[1101] #7: StorEdge Array SN#8008521 CH# ID#: SCSI Target ALERT: unexpected
select timeout
Fri Jan 2 06:54:04 2004
[2101] #8: LD-ID 3CD20C7E on StorEdge Array SN#8008521: ALERT: SCSI drive
failure (CH# ID#)
In cases of drive failure with symptoms shown above, refer to the Corrective
Action section to identify which components (drive, controller, or cables)
should be replaced.
Root Cause
----------
The issue with affected controllers is due to marginal components that affect
the reliability of the Fibre Channel disk loops. This results in intermittent
CRC errors on the disk loops that may lead to a shutdown of the controller due
to an identified firmware bug (5012640).
It has also been found that affected JBOD FC jumper cable(s) can contribute to
Fibre Channel reliability issues due to a mating issue with the Finisar SFP.
This mating issue creates an air gap when the cable is inserted into the SFP
resulting in unacceptable db loss.
The 3510 FC controller has been redesigned to minimize the effect of a marginal
component. This was an update to the RAID controller and the IOM board that is
all part of the controller FRU assembly beginning with the 05/50 release. The
TCC cables have been removed from the qualified list. New cables are being
shipped with the units to resolve the mating issue with the Finisar SFP and are
labeled BIZ 35-0000118-005A.
Corrective action was made available by engineering via ECOs WO_28721 and
WO_28832.
Corrective action was made available by Sun Services via LEAP# 2562 for the
controller and LEAP# 2563 for the cable.
Implementation:
---
| X | MANDATORY (Fully Pro-Active)
---
---
| | CONTROLLED PRO-ACTIVE (per Sun Geo Plan)
---
---
| | UPON FAILURE
---
Replacement Time Estimate:
1 hour
Special Considerations:
When this FCO was originally released as A0237-1, it was "Upon Failure". The
implementation has now changed to Mandatory. A new Corrective Action has been
provided for the re-release as FCO A0237-2.
Even though this is a mandatory FCO, the Corrective Action procedures can be
scheduled with other work on a planned account visit if appropriate.
Corrective Action:
Note: All StorEdge 3510 systems should be running at a mandatory firmware level
3.27R via patch 113723-07 (or above). Please read FIN# I1078-1 for complete
information.
Controllers
-----------
The "SE3510 Health Check Utility" provided in patch 113729-01 must be installed
proactively to screen for this issue. Please use the above Customer List for a
list of affected customers.
Refer to the URL below on how to run the SE3510 Health Check Utility to
proactively capture controller(s) and cables that can cause this issue as
described above:
http://webhome.sfbay/minnow_eng/utility_doc.html
Note: In the dual controller configuration, the utility cannot differentiate
which controller is affected by this issue.
If output from the Health Check Utility determines that the controller
is affected, replace as follows:
- replace 370-5537-04 (or below) with 370-5537-05 (or above)
Replace both controllers if they are at -04 or below. Do not replace
controllers at -05 or above.
Cables
------
Visually check for affected JBOD FC cables having the "TCC" label. If affected
cables are identified, replace as follows:
- replace 370-5540-02 (labeled TCC) or below
with 370-5540-03 (labeled BIZ) or above
Refer to the URL below to identify TCC cables:
http://webhome.sfbay/minnow_eng/TCC_cable.gif
Note: The following warning generated by the "SE3510 Health Check Utility" is
just a reminder to check the cable:
Jun 1 13:25:36 hba2-82 s3khc[1643]: 002294: Alert: Serial: 00223D,
Check the Sun StorEdge 3510 expansion FC Jumper Cables
The above message is not an indication that the cable is faulty or suspected. A
visual inspection is the ONLY way to screen for the cable issue. If the cable
is made by BIZ, please ignore the message.
Follow instructions on http://webhome.sfbay/minnow_eng/utility_doc.html
for "HOW TO REPLACE CABLE(S)".
Disk Drives
-----------
If there is an Amber LED on Sun StorEdge 3510 disk(s), please follow the
section "DRIVE AMBER LED PROCEDURES" in the "SE3510 Health Check Utility" at:
http://webhome.sfbay/minnow_eng/utility_doc.html
Comments:
Billing Type:
Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on how the
system was initially installed.
Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.
Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.
--------------------------------------------------------------------------
Implementation Footnote:
________________________
i) In case of Mandatory FCOs, Sun Services will attempt to contact
all known customers to recommend the part upgrade.
ii) For controlled proactive swap FCOs, Sun Services mission critical
support teams will initiate proactive swap efforts for their respective
accounts, as required.
iii) For Replace upon Failure FCOs, Sun Services partners will implement
the necessary corrective actions as and when they are required.
--------------------------------------------------------------------------
All released FINs and FCOs can be accessed using your favorite network
browser as follows:
SunSolve Internal Access:
_______________________
* Access the SunSolve Online URL at http://sunsolve.Central/
* From there, select the appropriate link to browse the FIN or FCO index.
Internet Access:
_______________
* Access the top level URL of https://spe.sun.com
FIN/FCO Homepage Access:
_________________________
* Access the top level URL of http://sdpsweb.Central/FIN_FCO/index.html
* From there, select the appropriate link to query or browse the FIN and
FCO Homepage collections.
To submit either a FIN or FCO refer to the following URLs for templates
and instructions;
* For FCO: http://pronto.central/fco.html
* For FIN: http://pronto.central/fin.html
--------------------------------------------------------------------------
General:
________
Send questions or comments to [email protected]
---------------------------------------------------------------------------