Problem Document Former IBIS ID Synopsis Last Modified Date
1020944.1 267788 SE3510: Hints for preventing overtemp conditions 2012-07-30
1020286.1 255568 SE35xx and SE33xx arrays - causes for slow LD rebuilds 2009-10-24
1018667.1 230369 Sun Storage[TM] 3510/3511 FC Array: Ghost Drive Presentive Configuration 2012-07-30
1012692.1 217449 Sun StorEdge [TM] 351x Array: How to Resolve Devices Missing from The Se3kxtr "show_frus" and "show_ses-devices" Output 2012-07-30
1012603.1 217345 Sun StorEdge[TM] 3000 series array: controller panic with message "WARNING: BBU cached data error!" 2012-07-30
1012553.1 217285 show persistent event: error: Undefined error code: -1 2012-07-30
1012505.1 217226 Sun StorEdge[TM] 3000 family: Resolving "Memory Not Sufficient to Fully Support Current Config" problem. 2012-07-30
1011087.1 215258 Sun StorEdge SE3510FC: Path sometimes fails to recover when fibre cable is unplugged/plugged 2012-07-31
1010881.1 215020 Fujitsu Disk Firmware Upgrade fails with Patch 116815-07 on Sun Storage 3510 Arrays 2012-07-31
1010855.1 214991 Sun Storage 3310/3320/3510/3511 Arrays: Identifying and Resolving an Incorrect "Controller Unique Identifier" 2012-07-04
1010521.1 214456 Sun StorEdge 3310/3320/3510/3511: Running sccli command may result in SCSI timeouts 2012-07-30
1010467.1 214381 Sun StorEdge[TM] 33x0 and 35x0:Symptom:SCCLI Fails to Find Controller 2012-07-30
1009497.1 213111 Sun StorEdge 3310/3510/3511/3320: Resolving Data Unavailability issues due to different default Cylinder/Head/Sector settings after firmware upgrade. 2012-07-31
1009437.1 213040 Sun StorEdge[TM] 3510 FC Array: Configuring with Crystal+ cards 2012-07-30
1009430.1 213031 Sun StorEdge[TM] 3310/3510/3120/3511 Array: Monitoring from more than one host using Sun StorEdge[TM] Configuration Service can cause the controller to not respond 2012-07-30
1009343.1 212925 SUNWjfca HBA will not have any bug fixes 2012-07-30
1009322.1 212902 Sun StorEdge[TM] 3310/3320/3510/3511 Array: Running concurrent/simultaneous se3kxtr scripts, may cause the array to hangup. 2012-07-30
1009137.1 212646 Sun StorageTek[TM] 351x/33x0: Resolving Drive NONE USED status for Raid 5 logical drives 2012-07-30
1008359.1 211430 Sun StorageTek[TM] 3xxx Arrays - Unable to change controller assignment on LogicalDisk 2009-03-10
1008108.1 211152 Sun StorEdge 3310, 3510 and 3511: Avoiding double drive failure conditions on 3.x firmware 2012-07-30
1007843.1 210836 Sun Storage 351x FC Arrays: Problem Unmapping Lun 0 with MPxIO 2012-07-31
1007803.1 210793 Sun Storage 3510/3511/3310/3320:"sccli>show-disks" : disk has NONE USED status by RAID 1 2012-07-30
1007648.1 210588 Sun StorEdge[TM] 3510 FC Array: Failure to Do a Full Fabric Login to a Switch 2012-07-30
1006983.1 209655 Sun Fire[TM] X4100/X4200: SE3510 luns not seen by the host upon boot. 2012-07-30
1006982.1 209654 Sun StorEdge[TM] 3510: Voltage/Temperature status seen as "Absent". 2012-07-30
1006649.1 209273 Sun StorEdge[TM] 3000 Arrays: 3.2x and 4.x Firmware Differences in Handling Media Errors 2012-07-30
1006534.1 209134 Sun StorEdge[TM] 3510 FC Array: Repeated disk failures 2012-07-30
1006168.1 208637 Solaris[TM] Errors During Boot with "Failed to create nodes for pwwn" 2012-07-30
1006040.1 208424 Sun StorEdge[TM] 3x10 Array: newfs fails with Error on "minimum cylinders per group" 2012-07-30
1004958.1 206952 StorEdge[TM] 3510FC Array Controller LED Amber,"show fru" Missing FRUs 2012-07-30
1004931.1 206916 Sun StorEdge[TM] 3510 Array: SES Firmware Upgrade Fails with sccli Error: sm_err_fw_download_failed 2012-07-30
1004033.1 205624 Clean-Up of disk scanned in on channel 2 and 3 on Sun StorEdge[TM] 3510 2012-07-30
1003864.1 205426 Invalid ID 125 on Sun StorEdge[TM] 3510 causing multiple drive/loop problems. 2012-07-30
1003771.1 205306 Sun StorEdge[TM] Diagnostic Reporter: "Server not online" error 2012-07-30
1003547.1 204988 Sun StorEdge[TM] 3510/3511/3310/3320: Getting "soft errors" reported by iostat 2011-01-06
1003545.1 204986 Sun StorEdge[TM] 3510:How to restore a missing back-end (drive channel) loop. 2009-09-24
1003518.1 204945 Resolving "NVRAM CRC Error: NVRAM Must be Reinitialized" on Sun StorEdge[TM] 3510 Array 2012-07-30
1003484.1 204886 Sun Storage 3510 FC Array: Getting Command Timeouts for LUNS in a SAN Configuration 2012-07-30
1002745.1 203760 Sun StorEdge[TM] 3510/3511 - RAID Firmware interface does not always discover attached HBAs 2009-08-13
1002403.1 203365 Sun StorEdge[TM] 3310 Array: Controller Unique Identifier not properly updated with 1159/1170 SAF-TE firmware installed 2009-02-11
1002332.1 203269 Checking the Actual Cache Status of The Sun Storage 3000 Array 2012-07-30
1002296.1 203223 Sun StorEdge[TM] 3310/3320/3510/3511: Duplicate disk entries from show disks output 2012-07-30
1002220.1 203139 Sun StorEdge[TM] 3000 Arrays: Battery Not Fully Charged 2011-11-29
1001846.1 202529 Sun StorEdge[TM] 3510/3511 FC Array/3310/3320 SCSI Array: Battery Display on Firmware GUI Appears to Be Incorrect 2009-11-08