Sun Microsystems, Inc.   Sun System Handbook - ISO 4.1 October 2012 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge 3310 SCSI Array : Problem Documents


Problem Document Former IBIS ID Synopsis Last Modified Date
1020286.1 255568 SE35xx and SE33xx arrays - causes for slow LD rebuilds 2009-10-24
1020033.1 251226 SE3xxx - After growing LD, new size is not reflected on host 2009-06-14
1012692.1 217449 Sun StorEdge [TM] 351x Array: How to Resolve Devices Missing from The Se3kxtr "show_frus" and "show_ses-devices" Output 2012-07-30
1012603.1 217345 Sun StorEdge[TM] 3000 series array: controller panic with message "WARNING: BBU cached data error!" 2012-07-30
1012505.1 217226 Sun StorEdge[TM] 3000 family: Resolving "Memory Not Sufficient to Fully Support Current Config" problem. 2012-07-30
1011981.1 216417 Sun StorEdge[TM] 3310:Unable to see a 3310 After Installing Patches and Rebooting 2012-07-30
1011232.1 215427 Recovering From a Failed SAF-TE Firmware Update on Sun Storage 33x0 RAID Arrays 2012-07-30
1010881.1 215020 Fujitsu Disk Firmware Upgrade fails with Patch 116815-07 on Sun Storage 3510 Arrays 2012-07-31
1010855.1 214991 Sun Storage 3310/3320/3510/3511 Arrays: Identifying and Resolving an Incorrect "Controller Unique Identifier" 2012-07-04
1010521.1 214456 Sun StorEdge 3310/3320/3510/3511: Running sccli command may result in SCSI timeouts 2012-07-30
1010467.1 214381 Sun StorEdge[TM] 33x0 and 35x0:Symptom:SCCLI Fails to Find Controller 2012-07-30
1009497.1 213111 Sun StorEdge 3310/3510/3511/3320: Resolving Data Unavailability issues due to different default Cylinder/Head/Sector settings after firmware upgrade. 2012-07-31
1009430.1 213031 Sun StorEdge[TM] 3310/3510/3120/3511 Array: Monitoring from more than one host using Sun StorEdge[TM] Configuration Service can cause the controller to not respond 2012-07-30
1009395.1 212991 Sun StorEdge[TM] 3310: Some sccli commands run in-band give error: ?this operation is only supported on RAID primary controllers? 2012-07-30
1009343.1 212925 SUNWjfca HBA will not have any bug fixes 2012-07-30
1009322.1 212902 Sun StorEdge[TM] 3310/3320/3510/3511 Array: Running concurrent/simultaneous se3kxtr scripts, may cause the array to hangup. 2012-07-30
1009137.1 212646 Sun StorageTek[TM] 351x/33x0: Resolving Drive NONE USED status for Raid 5 logical drives 2012-07-30
1008956.1 212345 Sun StorEdge[TM] 3310 (SE3310) - Solaris[TM] unable to see any mapped LUNs, or LUNs other than LUN 0 2009-02-18
1008359.1 211430 Sun StorageTek[TM] 3xxx Arrays - Unable to change controller assignment on LogicalDisk 2009-03-10
1008108.1 211152 Sun StorEdge 3310, 3510 and 3511: Avoiding double drive failure conditions on 3.x firmware 2012-07-30
1008091.1 211134 vxvm 3.5/4.0/4.1 hangs during install on systems with a Sun StorEdge[TM] 3310 running firmware rev 325W 2012-07-30
1007982.1 211012 Sun StorEdge[TM] 3310 without configured lun0 shows narrow channel setting. 2012-07-30
1007803.1 210793 Sun Storage 3510/3511/3310/3320:"sccli>show-disks" : disk has NONE USED status by RAID 1 2012-07-30
1007691.1 210658 [3310] ssmon can generate ASC: 0x29 (power on, reset, or bus reset occurred) 2012-07-30
1006888.1 209553 Sun StorEdge 3310 SCSI array connected with Ultra320 SCSI HBA: Fujitsu (Allegro) drives can cause SCSI bus resets and transport errors. 2012-07-31
1006649.1 209273 Sun StorEdge[TM] 3000 Arrays: 3.2x and 4.x Firmware Differences in Handling Media Errors 2012-07-30
1006542.1 209143 Sun StorEdge[TM] 3310 SCSI Array/JBODs: Connecting to the onboard SCSI port on Sun Enterprise[TM] 3x00/4x00/5x00/6x00 servers may give SCSI errors 2012-07-30
1006445.1 209034 Sun StorEdge[TM] 3310 SCSI Array: SCSI error message "f/w initiated BDR fails" 2012-07-30
1004867.1 206829 Sun StorEdge[TM] 3310:Symptom:3310 not seen when connected to LVD SCSI-3 (jasper) HBA 2009-09-13
1004789.1 206648 Sun StorEdge[TM] 3310:Symptom:ssconsole unable to discover array 2012-07-30
1004782.1 206640 probe-scsi-all can see disks, but boot -r, devfsadm , and drvconfig, fail to add disks to OS 2012-07-30
1004263.1 205891 Sun StorEdge[TM] 3310 SCSI Array: Unrecoverable media errors not passed to the host 2009-03-01
1003771.1 205306 Sun StorEdge[TM] Diagnostic Reporter: "Server not online" error 2012-07-30
1003736.1 205265 Avoiding SCSI transport errors while running explorer/extractor/sccli with Sun Storage 3310 Arrays 2012-07-30
1003547.1 204988 Sun StorEdge[TM] 3510/3511/3310/3320: Getting "soft errors" reported by iostat 2011-01-06
1003518.1 204945 Resolving "NVRAM CRC Error: NVRAM Must be Reinitialized" on Sun StorEdge[TM] 3510 Array 2012-07-30
1002403.1 203365 Sun StorEdge[TM] 3310 Array: Controller Unique Identifier not properly updated with 1159/1170 SAF-TE firmware installed 2009-02-11
1002332.1 203269 Checking the Actual Cache Status of The Sun Storage 3000 Array 2012-07-30
1002296.1 203223 Sun StorEdge[TM] 3310/3320/3510/3511: Duplicate disk entries from show disks output 2012-07-30
1002220.1 203139 Sun StorEdge[TM] 3000 Arrays: Battery Not Fully Charged 2011-11-29
1001846.1 202529 Sun StorEdge[TM] 3510/3511 FC Array/3310/3320 SCSI Array: Battery Display on Firmware GUI Appears to Be Incorrect 2009-11-08
  Copyright © 2012 Sun Microsystems, Inc.  All rights reserved.