Processor |
Number |
Up to 8 |
Architecture |
Type: AMD Opteron 8000 Series
Model
|
Speed
|
Core
|
WATTs
|
8216
|
2.4 GHz |
Dual-Core
|
95W
|
|
8218
|
2.6 GHz |
Dual-Core
|
95W
|
|
8220
|
2.8 GHz |
Dual-Core
|
95W
|
|
8220SE
|
2.8 GHz |
Dual-Core
|
120W
|
|
8222
|
3.0 GHz |
Dual-Core
|
95W
|
|
8224SE
|
3.2 GHz |
Dual-Core
|
120W
|
|
8347HE
|
1.9 GHz |
Quad-Core
|
55W
|
|
8356
|
2.3 GHz |
Quad-Core
|
75W
|
|
8360SE
|
2.5 GHz |
Quad-Core
|
105W
|
|
8384
|
2.7 GHz |
Quad-Core
|
75W
|
|
8389
|
2.9 GHz |
Quad-Core
|
75W
|
|
8380
|
2.5 GHz |
Quad-Core
|
75W
|
|
|
Sun Fire X4600 (Model 1) difference:
|
See Model 1 CPU specifications.
The Model 1 uses AMD Opteron 800 series CPUs.
BIOS revisions differ between the AMD Opteron 8000 and 800 series. BIOS
downloads are available at: http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp-138416.html#X4600
|
Main Memory |
Capacities |
DIMM slots per CPU Socket: Two configurations: 4 or 8 DIMM Slots
DIMM sizes:1-GB, 2-GB, 4-GB, or 8-GB
Maximum capacity using 4 DIMM Slot CPU/Memory Boards: 256GB (when configured with 8-GB DIMMs and 8 CPU Modules)
Maximum capacity using 8 DIMM Slot CPU/Memory Boards: 512GB (when configured with 8-GB DIMMs and 8 CPU Modules)
|
Sun Fire X4600 (Model 1) difference:
|
See Model 1 Memory specifications.
The Model 1 uses DDR1/400 memory.
DIMM slot locations differ between DDR1 and DDR2 DIMMs. Refer to Sun Fire X4600 and Sun Fire X4600 M2 service documentation for DIMM installation information.
|
Standard Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports, RJ45 connectors |
Network Management |
One dedicated 10/100Base-T Ethernet port, RJ45 connector |
Serial Management |
RS-232 Serial Interface, RJ45 connector |
SAS |
Four channel SAS interface |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports |
Expansion bus |
8 Low Profile PCI Expansion slots
- 2 64-bit/100 MHz PCI-X slots
- 6 PCIe slots (4 x 8-lane PCI slots, 2 x 4-lane PCI slots)
- 2 socket configurations ** have:
3 PCIe slots (2 x 8-lane PCI slots, 1 x 4-lane PCI slots)
|
Internal Mass Storage |
Disks |
Internal: Up to four 73GB or 146GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 10K.
Up to four 73GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 15K.
|
DVD-ROM |
One EIDE DVD-ROM |
Power Supplies |
Four hot-swappable power supplies, redundant in 2+2 configuration;
Available Power Supplies: 950 Watt, Type A222 and 1133 Watt, Type A238.
|
Environment |
AC power |
90-264 V AC (47-63 Hz)
1137 W; 3880 BTU/HR; .32 Tons of Air Conditioning (4xCPU/2HDD/4x2GB/7 PCI cards)
1603 W; 5470 BTU/HR; .46 Tons of Air Conditioning (8xCPU/2HDD/8x2GB/7 PCI cards)
Note:The power results represent the worse-case, maximum sustained total server power for room temps below 23° C |
Temperature |
Single, non-rack system:
Operating: 5° C to 32° C (41° F to 90° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating:32° C up to 900 meters and derating of 1°C for every 300 meters
in altitude up to 3048 meters maximum
Nonoperating: up to 12,000 m (40,000 ft.)
|
Acoustic noise (Measure and Environment) |
Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling:
Less than 83 dB sound power in ambient temperature of up to 24° C |
LwAd (1B=10dB)
at or below 25C
at max ambient |
8.1 B
8.9 B
|
LpAm bystander
at or below 25C
at max ambient |
66 dB
74 dB
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC60950, UL/CSA60950-1, EN60950, (CB Scheme with all country differences) |
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.3.2, ICES-003 |
Immunity |
EN55024, EN300-386:v1.3.2 |
Certifications |
Safety: cULus Mark, CE Mark, CCC, GOST R, S-Mark
EMC: CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels:
FCC, VCCI, BSMI, C-Tick, MIC, CCC (Applicable at GA), GOST R, BSMI
Other: Labeled per WEEE (Waste Electrical and Electrical Equipment) Directive |
Dimensions and Weight |
Height |
176 mm (6.9 in.) |
Width |
445 mm (17.5 in.) |
Depth |
629 mm (24.75 in.) |
Weight |
40 kg (88 lb.) Maximum standalone server
48 kg (106 lb.) Maximum with orderable rack-mount kit and cable management arm |
Rack Mounting |
Optional Slide Rail Kit (X8095A-Z) is a 4-point mounted slide rail kit. |
Optional Slide Rail Kit (X8095A-Z) and optional Cable Management Arm (8094A-Z) enables X4600 to be racked in:
- Sun Rack 900 (-38 and -36N)
- Sun Rack 1000 (-38 and -42)
- Third Party ANSI/EIA-310-D-1992 or IEC 60927 compliant racks in 19-inch/482.6 mm panel width series.
|
The slide kit includes hardware that enables mounting to any of the following
types of rack rails:
- M6 threaded holes
- #10-32 threaded holes
- #10 to M6 clearance holes
- Square unthreaded holes per EIA and IEC starndards listed above
|
Rack Density:
Sun Fire X4600 Server Rack Density will vary widely based on systems installed, power distribution
installation (in-cabinet, external), power source (single-phase, three-phase) and whether redundant power is required.
|