Processor |
Number |
Up to 8 (Single or Dual-Core) |
Architecture |
Type: AMD Opteron Processor 800 Series
Single Core: 856 (3.0GHz)
Dual Core: 885 (2.6GHz) |
Cache memory |
1 MB Level 2 |
Sun Fire X4600 M2 difference:
|
See Model 2 (M2) CPU specifications.
The M2 uses AMD Opteron 8000 series CPUs.
BIOS revisions differ between the AMD Opteron 800 and 8000 series. BIOS
download for Sun Fire X4600 is available at: https://updates.oracle.com/download/10331148.html
|
Main Memory |
Capacities |
DIMM slots per CPU Socket: 4
DIMM sizes:1-GB, or 2-GB
Maximum capacity: 64GB (when configured with 2-GB DIMMs and 8 CPU Modules)
|
Sun Fire X4600 M2 difference:
|
See Model 2 (M2) Memory specifications.
The M2 uses DDR2-667 memory.
DIMM slot locations differ between DDR1 and DDR2 DIMMs. Refer to Sun Fire X4600 and Sun Fire X4600 M2 service documentation for DIMM installation information.
|
Standard Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports, RJ45 connectors |
Network Management |
One dedicated 10/100Base-T Ethernet port, RJ45 connector |
Serial Management |
RS-232 Serial Interface, RJ45 connector |
SAS |
Four channel SAS interface |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports |
Expansion bus |
8 Low Profile PCI Expansion slots
- 6 PCIe slots (4 x 8-lane PCI slots, 2 x 4-lane PCI slots)
- 2 64-bit/100 MHz PCI-X slots
|
Internal Mass Storage |
Disks |
Internal: Up to four 73GB or 146GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 10K
Up to four 73GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 15K.
|
DVD-ROM |
One EIDE DVD-ROM |
Power Supplies |
Four hot-swappable power supplies, redundant in 2+2 configuration;
120W processors only supported with 3+1 configuration (i.e. All power cords must be connected to same power source).
Some earlier rev E based product were shipped with 3+1 power support.
(Power source 100-240 VAC - 50/60 Hz input)
(UL Maximum (DC output) = 850W)
(Typical Power Consumption: 40 W/PSU) |
Environment |
AC power |
90-264 V AC (47-63 Hz) |
Temperature |
Single, non-rack system:
Operating: 5° C to 32° C (41° F to 90° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating:32° C up to 900 meters and derating of 1°C for every 300 meters
in altitude up to 3048 meters maximum
Nonoperating: up to 12,000 m (40,000 ft.)
|
Acoustic noise (Measure and Environment) |
Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling:
Less than 83 dB sound power in ambient temperature of up to 24° C |
LwAd (1B=10dB)
at or below 25C
at max ambient |
8.1 B
8.9 B
|
LpAm bystander
at or below 25C
at max ambient |
66 dB
74 dB
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC60950, UL/CSA60950-1, EN60950, (CB Scheme with all country differences) |
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.3.2, ICES-003 |
Immunity |
EN55024, EN300-386:v1.3.2 |
Certifications |
Safety: cULus Mark, CE Mark, CCC, GOST R, S-Mark
EMC: CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels:
FCC, VCCI, BSMI, C-Tick, MIC, CCC (Applicable at GA), GOST R, BSMI
Other: Labeled per WEEE (Waste Electrical and Electrical Equipment) Directive |
Dimensions and Weight |
Height |
176 mm (6.9 in.) |
Width |
445 mm (17.5 in.) |
Depth |
629 mm (24.75 in.) |
Weight |
40 kg (88 lb.) Maximum standalone server
48 kg (106 lb.) Maximum with orderable rack-mount kit and cable management arm |
Rack Mounting |
Optional Slide Rail Kit (X8095A-Z) is a 4-point mounted slide rail kit. |
Optional Slide Rail Kit (X8095A-Z) and optional Cable Management Arm (8094A-Z) enables X4600 to be racked in:
- Sun Rack 900 (-38 and -36N)
- Sun Rack 1000 (-38 and -42)
- Third Party ANSI/EIA-310-D-1992 or IEC 60927 compliant racks in 19-inch/482.6 mm panel width series.
|
The slide kit includes hardware that enables mounting to any of the following
types of rack rails:
- M6 threaded holes
- #10-32 threaded holes
- #10 to M6 clearance holes
- Square unthreaded holes per EIA and IEC starndards listed above
|