This section provides the most common repair procedures for the 
  Enterprise 3500. The written procedures below are links to the 
Sun 
  Enterprise 3500 System Reference Manual (805-2630). 
   
    | Component | 
     
       Remove 
     | 
     
       Install 
     | 
    Tips | 
  
   
    | CD-ROM Drive | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Centerplane | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Clock+ Board | 
     
      
     | 
     
      
     | 
      | 
  
   
    | CPU/Memory+ Board | 
     
      
     | 
     
      
     | 
     
      
        -  
          
New service procedures are available for detached 
            heat sinks on EXX00 CPU and I/O boards (FIN  I0683-1).
            
         
       
     | 
  
   
    | CPU Modules | 
     
      
     | 
     
      
     | 
     
      
        -  
          
        
 
        - Sun Enterprise 6x00, 5x00, 4x00, 
          and 3x00 Systems Torque Screwdriver for UltraSPARC Module Installation 
          Guide
 
        -  
          
            Tuning the ecache_scan_rate parameter of the Solaris 
              cache scrubber provides improved Ecache parity error protection 
              on non-mirrored SRAM UltraSPARC II-based systems (FIN  I0755-1).  
         
         
        - 
          
Booting from the network can fail with Solaris 2.5.1 
            and Solaris 2.6 when using 464MHz or faster processors (FIN  I0707-1).  
         
        -  
          
Any Fatal Reset errors in the UE 3X00 to UE 6X00 servers 
            should be evaluated to determined whether it is because of Ecache 
            Tag error. Do not assume that a Fatal Reset error implies that the 
            system board is defective (FIN  I0587-1).  
         
        -  
          
The current diagnostic procedure to identify the faulty 
            CPU module from CPU Ecache parity errors is flawed, and it could easily 
            lead to the wrong CPU being replaced (FIN  I0570-3).  
         
        -  
          
Cleaning kit available for cleaning silicon oil from 
            CPU module on the system board (FIN  I0567-1). 
            
         
        -  
          
Failure to handle CPU Modules correctly can result 
            in physical damage; proper torquing techniques are required (FIN  I0403-2). 
            
         
       
     | 
  
   
    |  
       Disk Drive 
     | 
     
      
     | 
     
      
     | 
     
      
        - Seagate ST336605FC 36GB and ST373405FC 73G drives could be susceptible 
          to label corruption (FIN I0816-1).
 
        - Error installing Solaris on ST318304 FC-AL disk drives: Could not 
          create Solaris disk label (VTOC) (SRDB 24407).
 
        - E3500 boot after replacing system disk (SRDB 17658).
 
        - Recovering from a failed FCAL boot disk (SRDB 17643).
 
       
     | 
  
   
    | Fan Tray Assembly | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Fan Tray Assembly, Auxiliary | 
     
      
     | 
     
      
     | 
      | 
  
   
    | GBIC | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Graphics (UPA) Card | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Interface Board | 
     
      
     | 
     
      
     | 
      | 
  
   
    | I/O+ Board | 
     
      
     | 
     
      
     | 
     
      
        -  
          
Ultra Enterprise Exx00 I/O Boards can fail with FEPS 
            error during POST if installed in a slot where there are damaged spring 
            fingers (FIN  I0800-1).  
         
        -  
          
New service procedures are available for detached 
            heat sinks on EXX00 CPU and I/O boards (FIN  I0683-1).  
         
        - Clarification of the hardware and software requirement to connect 
          the onboard SOC+ device on I/O boards used with an A3500FC StorEdge 
          Array (FIN I0586-1).
 
       
     | 
  
   
    | Memory  | 
     
      
     | 
     
      
     | 
     
      
        -  
          
When using mixed density memory modules, certain combinations 
            of memory banks result in fatal reset while running POST before a 
            system boot (FIN  I0588-1). 
            
         
        -  
          
ECC Memory Error Guidelines for Enterprise servers 
            (FIN  I0377-1).  
         
        - How to read prtdiag memory interleaving on Ultra servers (SRDB 21869).
 
        - OBP requirements for Enterprise servers when installing 2GB Memory 
          kit ( 8 X 256MB) (InfoDoc 27710).
 
       
     | 
  
   
    | PCI Card | 
     
      
     | 
     
      
     | 
     
      
        - Systems with a PGX PCI-based 8-bit Frame Buffer may display a vertical 
          black stripe when running the OpenWindows environment (FCO A0139-1).
 
        - Solaris 2.5.1 on Ultra cannot boot over the network on the FDDI 4.0 
          card (SRDB 14581).
 
        - PCI i/o card address mapping on Ultra Enterprise servers (InfoDoc 
          17576).
 
       
     | 
  
   
    | Peripheral Power Supply (PPS0) | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Peripheral Power Supply (PPS1) | 
     
      
     | 
     
      
     | 
      | 
  
   
    | Power/Cooling Module (PCM) | 
     
      
     | 
     
      
     | 
     
      
        - Power/Cooling module handling and fault diagnosis N+1 configurations 
          may suffer a Silent Mode Failure (FIN I0599-1).
 
       
     | 
  
   
    | SBus Card | 
     
      
     | 
     
      
     | 
     
      
        - Customers using SBus Dual FC Adapter (X6757A) at Rev. 50 may notice 
          slow performance on sequential write operations (FIN I0821-1).
 
        - UDWIS SBus Host Adapter with isp-fcode 1.28 can cause "invalid command" 
          during probe-scsi-all or boot -hv from a StorEdge D1000 (FIN I0569-1).
 
        - Sun FDDI SBus Adapter 5.0 SAS/DAS mounting screws may not fit the 
          EMI plate due to excessive plating (FIN I0469-1).
 
        - SunATM-155 SBus board replacement may render interface unrecognizable 
          (FIN I0412-1).
 
        - Large quantities of UDWIS/SBus Host Adapters installed may not come 
          up after reboot due to miscommunication between the SCSI host and the 
          target (FCO A0163-1). 
        
 
       
     | 
  
   
    | Tape Drive | 
     
      
     | 
     
      
     | 
     
      
        - Firmware upgrade for EOL Mammoth 8mm tape drive (FIN I0516-1).
 
        - All support calls related to the Exabyte Mammoth II tape drive need 
          to be forwarded to Exabyte (FIN I0719-1).
 
       
     |