Processor |
Number |
Up to two (maximum)
Both processors communicate with each other and the system I/O
through the 200MHZ Jbus interface, which operates at a bandwidth of 3.2Gbit per second. |
Architecture |
1.6GHz UltraSPARC IIIi:
|
Cache memory |
1MB Level 2 |
Main
Memory |
Capacities |
Characteristics of the ECC-protected memory include:
- Maximum system memory - 16GB (DDR-1)
- Maximum memory per CPU - 8GB (using 2GB DIMMS)
- Maximum DIMMS per CPU - 4 (8GB max per processor)
- Maximum DIMM slots - 8 (4 slots per CPU)
- Two physical banks of two DIMMs per CPU
- DIMM sizes offered - 512MB, 1GB, or 2GB
- DDR-1 registered ECC memory at 266 MHz
- Processor accesses memory across the 128-bit data bus. Must be installed in pairs.
|
Standard
Interfaces |
Audio |
Four AC97 ports as follows:
|
Ethernet |
Two 10/100/1000 BaseT (Gigabit) ethernet ports (rear of workstation) |
Expansion Slots |
Five slots as follows:
- Two PCI-Express: both mechanical (x16) and electrically (x8)
- One PCI-Express mechanical (x8) and electrically (x4)
- Two PCI-X 100MHz/64 bit slots
|
Serial |
Two ports (rear of workstation) |
USB |
Six ports as follows:
- Two USB 2.0 ports in front
- Four USB 2.0 ports in rear
|
Internal
Storage |
Disks |
Allows a maximum of four internal 3.5" SAS (146GB - 15000 RPM) or SATA (250GB - 7200 RPM) disk drives.
Drives are supported by an integrated PCI-X SAS/SATA disk controller.
|
Optical Disk Drives |
Optical disk drive as follows:
- One DVD-RW - Slot-loading
- ATAPI - Interface
Note: Systems that ship without an optical disk drive require an optical disk drive EMI filler panel in the
unoccupied bay to cover the slot opening.
|
Graphics |
Cards |
Note: Solaris 10 currently does not support dual graphics cards, each driving a monitor.
|
Environment |
AC Power |
Voltage: 110-127/200-240 VAC
Frequency: 50-60 Hz, 10/6 Amps |
Input Current |
6.4 amps @ 100 VAC, 3.2 amps @ 200 VAC
|
Power consumption |
Power Supply - 1000 Watts (maximum) |
Temperature |
Operating: 5° C to 35° C at 3000 meters
Nonoperating:-40° C to 60° C at 12000 meters |
Humidity |
Operating: 7% to 93% relative humidity, non-condensing
Nonoperating: 93% relative humidity, non-condensing
|
Acoustic noise |
Operating:LWAd (1B=10db) 5.0 B
LpAm (by standard position) 42 dBA
Idling: LWAd (1B=10db) 4.5 B
LpAm (by standard position) 38 dBA |
Shock |
Operating: 5 G's, 11 msec, half-sine
Nonoperating: 30 G's, 11 msec, half-sine
|
Regulations |
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:Y |
Safety |
IEC60950, UL60950, EN60950, CSA C22.2 CB |
RFI/EMC |
FCC B, VCCI B, EN55022 B |
Immunity |
EN55024 All applicable levels |
Regulatory Markings |
FCC, VCCI, ICES-003, CCC, C-tick, GOST, MIC, Argentina S mark, EEE, BSMI
|
Ergonomics |
EK1-1TB-2000 |
Power Management |
EPA MOU 3 |
Dimensions
and Weights |
Height |
445 mm (17.5 in) |
Width |
205 mm (8.1 in) |
Depth |
569 mm (22.4 in) |
Weight |
26.31 kg (58 lbs) fully configured |