Processor |
Number |
Up to two (maximum) |
Architecture |
AMD Opteron Processor (940-pin, 200-series):
- Model 285 - 2.6GHz, Dual Core
- Model 280 - 2.4GHz, Dual Core
- Model 275 - 2.2GHz, Dual Core
- Model 256 - 3.0GHz, Single Core
- Model 254 - 2.8GHz, Single Core
- Model 250 - 2.4GHz, Single Core
- Model 248 - 2.2GHz, Single Core
- Model 246 - 2.0GHz, Single Core
|
Cache memory |
1MB Level 2 |
Main
Memory |
Capacities |
Characteristics of the ECC-protected memory include:
- Maximum system memory - 32GB (DDR1-400/PC3200)
- Maximum memory per CPU - 16GB (using 4GB DIMMS)
- Maximum DIMMS per CPU - 4
- Maximum DIMM slots - 8 (4 slots per CPU)
- DIMM sizes offered - 512MB, 1GB, 2GB, 4GB
- DDR1-400/PC3200 memory - must be installed in pairs
|
Chipkill Memory Support |
This type of architecture allows:
- A single DRAM chip to fail (not the DIMM, just a chip on the DIMM) and the system will continue to operate.
- DIMM replacement to occur at regularly-scheduled service intervals.
|
Standard
Interfaces |
Audio |
Ten AC97 ports as follows:
- Two in front
- Eight in rear
|
Ethernet |
Two 10/100/1000 Base-T Gigabit ethernet ports (rear of workstation) |
Expansion Slots |
Six slots as follows:
- Two PCI-Express x16 slots (reserved for graphics)
- Two PCI-Express x4 expansion slots
- Two PCI slots (32-bit, 33MHz)
|
Fire Wire |
Two IEEE 1394a ports (front of workstation) |
USB |
Eight Serial Bus 2.0 ports as follows:
|
Internal
Storage |
Disks |
Allows up to 4 SATA-2 disk drives (7200 RPM, 3.5 inch) in the following sizes:
- 80GB - 4 x 80GB drives = 320GB of total storage
- 250GB - 4 x 250GB drives = 1TB of total storage
- 500GB - 4 x 500GB drives = 2TB of total storage
Supports the following RAID levels:
- RAID 0
- RAID 1
- RAID 0+1
- RAID 5
|
DVD Dual Drive Combo |
Optical disk drive as follows:
- One DVD-ROM/CD-RW - Slot-loading
- ATAPI - Interface
Note: Systems that ship without an optical disk drive require an optical disk drive blank bezel to cover the slot opening.
|
Graphics |
Cards |
|
Environment |
AC Power |
Voltage: 90-264 VAC
Frequency: 47-63 Hz |
Input Current |
12A @ 100 VAC
10A @ 110-127 VAC
6A @ 200-240 VAC
|
Power consumption |
Power Supply - 1000 Watts (maximum) |
Temperature |
Operating: 2° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 158°
F) |
Humidity |
Operating: 7% to 93% relative humidity, non-condensing
Nonoperating: 93% relative humidity, non-condensing
|
Acoustic noise |
Operating: 4.9 bels
Idling: 4.7 bels |
Shock |
Operating: 4.5G, 11 msec
Nonoperating: 20G, 11 msec
|
Regulations |
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:Y |
Safety |
UL/CSA-60950, EN 60950, IEC 60950 CB |
RFI/EMI |
EN 55022/CISPR22 Class B, FCC CFR47 Part 15 Class B, EN 61000-3-2, EN
61000-3-3 |
Immunity |
EN 55024 |
Regulatory Markings |
UL/cUL, TUV-GS, CE FCC, ICES-003, C-Tiek, VCCI, GOST-R, BSMI, CCC, S-Mark
|
Ergonomics |
EK1-1TB-2000 |
Power Management |
Supports PowerNow standard ACPI power states |
Dimensions
and Weights |
Height |
445 mm (17.5 in) |
Width |
205 mm (8.1 in) |
Depth |
569 mm (22.4 in) |
Weight (fully configured) |
26.31 kg (58 lbs) |