Processor
Number Up to two (maximum)
Architecture AMD Opteron Processor (940-pin, 200-series):
  • Model 285 - 2.6GHz, Dual Core
  • Model 280 - 2.4GHz, Dual Core
  • Model 275 - 2.2GHz, Dual Core
  • Model 256 - 3.0GHz, Single Core
  • Model 254 - 2.8GHz, Single Core
  • Model 250 - 2.4GHz, Single Core
  • Model 248 - 2.2GHz, Single Core
  • Model 246 - 2.0GHz, Single Core
Cache memory 1MB Level 2
Main Memory
Capacities Characteristics of the ECC-protected memory include:
  • Maximum system memory - 32GB (DDR1-400/PC3200)
  • Maximum memory per CPU - 16GB (using 4GB DIMMS)
  • Maximum DIMMS per CPU - 4
  • Maximum DIMM slots - 8 (4 slots per CPU)
  • DIMM sizes offered - 512MB, 1GB, 2GB, 4GB
  • DDR1-400/PC3200 memory - must be installed in pairs
Chipkill Memory Support This type of architecture allows:
  • A single DRAM chip to fail (not the DIMM, just a chip on the DIMM) and the system will continue to operate.
  • DIMM replacement to occur at regularly-scheduled service intervals.
Standard Interfaces
Audio Ten AC97 ports as follows:
  • Two in front
  • Eight in rear
Ethernet Two 10/100/1000 Base-T Gigabit ethernet ports (rear of workstation)
Expansion Slots Six slots as follows:
  • Two PCI-Express x16 slots (reserved for graphics)
  • Two PCI-Express x4 expansion slots
  • Two PCI slots (32-bit, 33MHz)
Fire Wire Two IEEE 1394a ports (front of workstation)
USB Eight Serial Bus 2.0 ports as follows:
  • Two in front
  • Six in rear
Internal Storage
Disks Allows up to 4 SATA-2 disk drives (7200 RPM, 3.5 inch) in the following sizes:
  • 80GB - 4 x 80GB drives = 320GB of total storage
  • 250GB - 4 x 250GB drives = 1TB of total storage
  • 500GB - 4 x 500GB drives = 2TB of total storage
Supports the following RAID levels:
  • RAID 0
  • RAID 1
  • RAID 0+1
  • RAID 5
DVD Dual Drive Combo Optical disk drive as follows:
  • One DVD-ROM/CD-RW - Slot-loading
  • ATAPI - Interface
Note: Systems that ship without an optical disk drive require an optical disk drive blank bezel to cover the slot opening.
Graphics
Cards
Environment
AC Power Voltage: 90-264 VAC
Frequency: 47-63 Hz
Input Current 12A @ 100 VAC
10A @ 110-127 VAC
6A @ 200-240 VAC
Power consumption Power Supply - 1000 Watts (maximum)
Temperature Operating: 2° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 68° C (-40° F to 158° F)
Humidity Operating: 7% to 93% relative humidity, non-condensing
Nonoperating: 93% relative humidity, non-condensing
Acoustic noise Operating: 4.9 bels
Idling: 4.7 bels
Shock Operating: 4.5G, 11 msec
Nonoperating: 20G, 11 msec
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
Safety UL/CSA-60950, EN 60950, IEC 60950 CB
RFI/EMI EN 55022/CISPR22 Class B, FCC CFR47 Part 15 Class B, EN 61000-3-2, EN 61000-3-3
Immunity EN 55024
Regulatory Markings UL/cUL, TUV-GS, CE FCC, ICES-003, C-Tiek, VCCI, GOST-R, BSMI, CCC, S-Mark
Ergonomics EK1-1TB-2000
Power Management Supports PowerNow standard ACPI power states
Dimensions and Weights
Height 445 mm (17.5 in)
Width 205 mm (8.1 in)
Depth 569 mm (22.4 in)
Weight (fully configured) 26.31 kg (58 lbs)