Processor |
Number |
2 or 4 6-Core or 8-Core CPU Modules (CMODs)
Each CMOD contains two Intel Xeon Processor 7500 Series |
Architecture |
Type: Intel Xeon 7500 Processor Series |
CPUs |
Intel 2.00GHz 6-Core Xeon E7540, 105W
Intel 2.00GHz 8-Core Xeon X7550, 130W
Intel 2.00GHz 8-Core Xeon X7560, 130W
|
Cache memory |
256KB unified (data and instruction) Level 2 cache
12MB, 18MB or 24MB shared inclusive Level 3 cache |
Main
Memory |
Capacities |
DIMM slots: 128 DIMM slots, 32 DIMMs per CMOD
DIMM type: Registered DDR3-1066/PC3-10600 ECC DIMMs
Registered DDR3-1066/PC3-8500 ECC DIMMs
DIMM size: 2GB, 4GB, 8GB
Maximum capacity: 1TB |
Standard Integrated Interfaces |
USB |
Internal: One USB Port (supported for CMOD0/BL0 only) |
PCI Interfaces |
I/O is offered in two form factors:
- PCI Express ExpressModules (EM):
- Up to eight rear, hot-swappable PCIe 2.0 ExpressModule slots.
- Each EM has a x8 electrical/x8mechanical PCIe 2.0 bus.
and
- PCI Express Network Express Modules (NEM):
- Two hot-swappable NEMs, each NEM provides:
- Four 10GbE network ports via SFP+ connectors.
- Four 1GbE network ports via RJ-45 connectors.
- Two x4 mini SAS-2 ports (not supported)
|
Internal
Mass Storage |
Disks |
Up to 8 hot-swappable disks
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS-2
|
300GB
|
10,000 RPM
|
2.5"
|
|
Power
Supplies |
Four redundant, Hot-Swappable front accessible power supplies.
AC power: 200-240VAC (47 Hz-63 Hz)
|
Environment |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158°
F) |
Humidity |
Operating: 10% to 90% relative humidity noncondensing.
Nonoperating: up to 93% relative humidity noncondensing. |
Altitude |
Operating: Up to 3,048 m (10,000 ft.), maximum ambient temperature
is derated by 1° C for every 300 m (985 ft) above 900 m (2,952 ft).
Nonoperating: Up to 12,000 m (39,370 ft). |
Acoustic Noise Emissions |
LwAd (1B= 10dB) at max ambient: 7.7 B operating and 6.8 B idling.
|
Management Environment
|
Service Processor (SP) Module |
- Hot-swappable SP providing:
- Oracle Integrated Lights Out Manager (ILOM).
- Two 10/100Base-T management (NET MGT) (port 1 not used).
- One RJ-45 management serial port (SER MGT).
- Universal Connector Port (UCP) for connection to the multi port (dongle) cable.
- Multi Port (dongle) cable connection to UCP provides:
- USB: Two USB ports.
- Serial: One Serial RJ-45 port.
- VGA: One VGA 1024x768x16bit@60Hz graphics controller port.
- Chassis status LEDs.
- Remote power control.
- Remote Keyboard, Video, Mouse and virtual Storage (RKVMS).
- Secure remote access via Web-GUI interface over SSL.
- DMTF-style Command Line Interface over Serial or SSH 2.0.
- Authentication via Local, RADIUS, LDAP, or Active Directory.
- IPMI 2.0, SNMP v1, v2c, and v3
|
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC 60950-1, UL/CSA60950-1, EN60950-1, CB scheme with all country differences
EMC: FCC CFR 47 Part 15 Class A, EN 55022:2006 Class A, EN 61000-3-2:2000+A2:2005, EN 61000-3-3:1995 +A1:2001, EN55024:1998 +A1:2001 +A2:2003, EN300-386.
|
Certifications |
Country certifications safety/EMC: UL/cUL, CE, S-Mark, CSA C22.2 No. 60950-
03 EN 60950-01:2001, 1st Edition, IEC 60950-01:2001, 1st Edition, FCC, VCCI, ICES-003, C-Tick, KCC, GOST-R, BSMI Class A.
Other: Complies with WEEE (Waste Electrical and Electronic Equipment) Directive (2002/96/EC) and RoHS Directive (2002/95/EC). |
RoHS Compliance Level |
RoHS:Y |
Dimensions
and Weight |
Height |
218.75 mm (8.61 in.) |
Width |
445 mm (17.5 in.) |
Depth |
700 mm (27.56 in.) |
Weight |
81.65 kg (180 lb.)
|