Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4450, RoHS:YL Server: Hardware Specifications

Processor
Number
  • 2 or 4, Dual-Core 7200 series
  • 2 or 4, Quad-Core 7300 series
  • 1, 2, 3 or 4, Quad-Core or 6-Core 7400 series
Architecture Type: Intel Xenon
  • Dual-Core Intel Xeon E7220 (2x4MB L2, 2.93 GHz, 1066 MHz FSB, 80W)
  • Quad-Core Intel Xeon L7345 (2x4MB L2, 1.86 GHz, 1066 MHz FSB, 50W)
  • Quad-Core Intel Xeon E7320 (2x2MB L2, 2.13 GHz, 1066 MHz FSB, 80W)
  • Quad-Core Intel Xeon E7340 (2x4MB L2, 2.40 GHz, 1066 MHz FSB, 80W)
  • Quad-Core Intel Xeon X7350 (2x4MB L2, 2.93 GHz, 1066 MHz FSB, 130w)
  • Quad-Core Intel Xeon E7420 (8MB L3, 2.13 GHz, 1066 MHz FSB, 90w)
  • Quad-Core Intel Xeon E7440 (16MB L3, 2.40 GHz, 1066 MHz FSB, 90w)
  • 6-Core Intel Xeon L7455 (12MB L3, 2.13 GHz, 1066 MHz FSB, 65w)
  • 6-Core Intel Xeon E7450 (12MB L3, 2.40 GHz, 1066 MHz FSB, 90w)
  • 6-Core Intel Xeon X7460 (16MB L3, 2.66 GHz, 1066 MHz FSB, 130w)
Cache memory 4MB to 8MB L2 cache for Intel Xeon processor 7200 and 7300 series
8MB to 16MB L3 cache for Intel Xeon processor 7400 series
Main Memory
Capacities DIMM slots per System: 32
DIMM type: PC2-5300 667MHz ECC Fully Buffered DDR2 DIMMs
DIMM size: 1-GB, 2-GB or 4-GB
Maximum capacity: 128GB (when configured with 4-GB DIMMs)
NOTE: For optimal performance, install DIMMs in matched pairs. DIMM fillers should be installed in all unoccupied DIMM slots.
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Eight channel SAS interface, internal or external with add-on SAS Host Bus Adapter
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Six internal MD2 low profile PCI Express slots
(two x8 electrical/x16 mechanical, one x4 electrical/x16 mechanical and three x4 electrical/x8 mechanical)
Internal Mass Storage
Disks Up to eight 2.5" SAS internal hot-swap Disks

Drive Type
Density
Speed
Form Factor
SAS
73 GB
10,000 RPM
2.5"
SAS
73 GB
15,000 RPM
2.5"
SAS
146 GB
10,000 RPM
2.5"
SAS
300 GB
10,000 RPM
2.5"

Solid State Drives Up to six 32GB solid state drives
Removable Media One EIDE DVD+/-RW drive (optional)
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 1050W)
(UL Maximum AC input = 12 Amps RMS at 100 VAC)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature For Intel Xeon processor 7200 and 7300 series:
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F) with 50/80W CPU, 5° C to 31° C (41° F to 88° F) with 130W CPU
Nonoperating: -40° C to 65° C (-40° F to 149° F)

For Intel Xeon processor 7400 series:
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F) at sea level, 5° C to 31° C (41° F to 88° F) at altitude
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Single, non-rack system:
Operating: 7% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise For Intel Xeon processor 7200 and 7300 series:
Single, non-rack system:
LwAd (1B=10dB)
     6.8 B (idle) and 7.3 B (operating) for 1GB and 2GB DIMMs
     7.3 B (idle and operating) for 4GB DIMMs
LpAm bystander
     65.8 dB at max ambient

For Intel Xeon processor 7400 series:
Single, non-rack system:
LwAd (1B=10dB)
     7.3 B (idle and operating. room temp.), 7.7 B (max ambient)
LpAm bystander
     65.8 dB at max ambient

Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC 60950, UL/CSA 60950-1, EN 60950, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN 55022 Class A, EN 61000-3-2, EN 61000-3-3, EN300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, Gost-R, BSMI Class A
Dimensions and Weight
Height 88 mm (3.49 in.)
Width 426 mm (16.75 in.)
Depth 714 mm (28.125 in.)
Weight 25.6 kg (56.3 lb.) maximum with rack kit
Rack Mounting
Optional Slide Rail Kit (X6324A)1is a 4-point mounted slide rail kit.
Sun Fire X4450 server racks (using either the X6325A or X6326A rackmount kits) Racks are as follows:
  • Sun Rack 938
  • Sun Rack 1038
  • Sun Rack 1042
  • Third Party EIA-310-D-19922
1 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • 6 mm threaded holes
  • #10-32 threaded holes
  • #10 threaded holes
  •  Square unthereaded holes per EIA and IEC standards
2 These must be compliant racks which have mounting depths of 27-30 inches.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback