Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4270 Server: Hardware Specifications

Processor
Number 1 or 2 Intel Quad-Core
Architecture Type: Intel Xeon 5500 series Quad-Core Processors
CPUs Intel Xeon X5570 2.93 GHz (8MB cache, 6.4 GY/s QPI, SMT, Turbo, 95W)
Intel Xeon X5560 2.80 GHz (8MB cache, 6.4 GY/s QPI, SMT, Turbo, 95W)
Intel Xeon E5540 2.53 GHz (8MB cache, 5.86 GY/s QPI, SMT, Turbo, 80W)
Intel Xeon L5520 2.26 GHz (8MB cache, 5.86 GY/s QPI, SMT, Turbo, 60W)
Intel Xeon E5520 2.26 GHz (8MB cache, 5.86 GY/s QPI, SMT, Turbo, 80W)
Cache memory 8MB Level 2
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 2-GB, 4-GB, 8-GB 1066MHz or 4-GB 1333MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Four channel SAS interface, internal access only
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Six internal MD2 low profile 8-lane PCI Express slots (all with x8 mechanical connectors)
Internal Mass Storage
Disks SAS: Up to sixteen internal 2.5" SAS or SSD Disks with add-on SAS Host Bus Adapter
Drive Type
Density
Speed
Form Factor
SAS
73 GB
15,000 RPM
2.5"
SAS
300 GB
10,000 RPM
2.5"
SAS
146 GB
10,000 RPM
2.5"
Solid State Drive
32 GB
NA
2.5"
DVD-ROM One SATA DVD+/-RW drive
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 1050W)
(UL Maximum AC input = 1050W x 1.33 efficiency = 1397W)
(8.2 Amps RMS at 100 VAC)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: up to 3048 m (10000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: 15kPa
Acoustic noise Single, non-rack system:
LwAd (1B=10dB)
     7.7 B at max ambient
LwAd bystander
     65.8 dB at max ambient
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL/cUL, CE, BSMI, GOST-R, S-Mark, CSA C22.2 No. 60950-03
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
Dimensions and Weight
Height 84.84 mm (3.34 in.)
Width 425.5 mm (16.75 in.)
Depth 685.8 mm (27 in.)
Weight 22.27 kg (49 lb.)
Rack Mounting
Sun Fire x4270 Server Racks Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Third Party EIA-310-D-1992

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback