Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4170 Server: Hardware Specifications

Processor
Number 1 or 2 Quad-Core
Architecture Type: Intel Xeon Quad-Core Processors
CPUs Intel 2.26GHz Quad-Core Xeon E5520 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 80W)
Intel 2.26GHz Quad-Core Xeon L5520 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 60W)
Intel 2.53GHz Quad-Core Xeon E5540 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 80W)
Intel 2.80GHz Quad-Core Xeon X5560 (8MB L2, 6.4 GT/s QPI, SMT, Turbo, 95W)
Intel 2.93GHz Quad-Core Xeon X5570 (8MB L2, 6.4 GT/s QPI, SMT, Turbo, 95W)
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 2-GB, 4-GB, 8-GB 1066MHz or 4-GB 1333MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Four channel SAS interface, internal access only
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Three internal MD2 low profile PCI Express 2.0 slots (1 x16 electrical/mechanical, 2 x8 electrical/mechanical)
Internal Mass Storage
Disks SAS: Up to eight 2.5" SAS Disks with add-on SAS Host Bus Adapter
(300GB - 10000 RPM SAS or 146GB - 10000 RPM SAS or 73GB 15000 RPM SAS or 73GB 10000 RPM SAS)
DVD-ROM One SATA DVD+/-RW drive
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(8.2 Amps RMS at 100 VAC)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
LwAd (1B=10dB)
     7.7 B at max ambient
LpAm bystander
     65.8 dB at max ambient
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 43.43 mm (1.71 in.)
Width 425.5 mm (16.75 in.)
Depth 685.8 mm (27.0 in.)
Weight 16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Sun Fire X4170 Server Racks Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Third Party EIA-310-D-1992

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.