Processor |
Number |
1 or 2 Quad-Core |
Architecture |
Type: Intel Xeon Quad-Core Processors |
CPUs |
Intel 2.26GHz Quad-Core Xeon E5520 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 80W)
Intel 2.26GHz Quad-Core Xeon L5520 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 60W)
Intel 2.53GHz Quad-Core Xeon E5540 (8MB L2, 5.86 GT/s QPI, SMT, Turbo, 80W)
Intel 2.80GHz Quad-Core Xeon X5560 (8MB L2, 6.4 GT/s QPI, SMT, Turbo, 95W)
Intel 2.93GHz Quad-Core Xeon X5570 (8MB L2, 6.4 GT/s QPI, SMT, Turbo, 95W)
|
Main Memory |
Capacities |
Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 2-GB, 4-GB, 8-GB 1066MHz or 4-GB 1333MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000 Base-T Ethernet Ports
|
Network Management |
One dedicated 10/100Base-T Ethernet port |
Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four channel SAS interface, internal access only |
USB |
Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port |
PCI Expansion Slots |
Three internal MD2 low profile PCI Express 2.0 slots
(1 x16 electrical/mechanical, 2 x8 electrical/mechanical) |
Internal Mass Storage |
Disks |
SAS: Up to eight 2.5" SAS Disks with add-on SAS Host Bus Adapter
(300GB - 10000 RPM SAS or 146GB - 10000 RPM SAS or 73GB 15000 RPM SAS or 73GB 10000 RPM SAS)
|
DVD-ROM |
One SATA DVD+/-RW drive |
Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(8.2 Amps RMS at 100 VAC)
|
Environment |
AC power |
90-264 V AC (47-63 Hz) |
Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
7.7 B at max ambient
LpAm bystander
65.8 dB at max ambient
|
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country
differences |
RFI/EMI |
FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2,
EN61000-3-3, EN 300-386 |
Immunity |
EN55024, EN300-386 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
Dimensions and Weight |
Height |
43.43 mm (1.71 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
685.8 mm (27.0 in.) |
Weight |
16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
|
Rack Mounting |
Sun Fire X4170 Server Racks |
Racks are as follows:
- Sun Rack 900
- Sun Rack 1000-38
- Sun Rack 1000-42
- Third Party EIA-310-D-1992
|