Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4140 Server: Hardware Specifications

Processor
Number 1 or 2 Dual-Core or Quad-Core
Architecture Type: AMD Opteron Dual-Core or Quad-Core Processors
CPUs AMD 2.6GHz Dual-Core Opteron 2218HE
AMD 3.0GHz Dual-Core Opteron 2222, 95W
AMD 2.3GHz Quad-Core Opteron 2356, 75W
AMD 2.5GHz Quad-Core Opteron 2380, 75W
AMD 2.7GHz Quad-Core Opteron 2384, 75W
AMD 2.3GHz Quad-Core Opteron 2376HE, 55W
AMD 2.2GHz 6-Core Opteron 2427, 75W
AMD 2.4GHz 6-Core Opteron 2431, 75W
AMD 2.6GHz 6-Core Opteron 2435, 75W
Cache memory 2x1MB Level 2 for Dual-Core
4x512KB Level 2 for Quad-Core
Main Memory
Capacities Total DIMM slots: 16
DIMM type: PC2-5300 DDR2 667MHz Registered DIMMs (128 bit plus ECC databus)
DIMM size: 1-GB, 2-GB, 4-GB or 8-GB
Maximum capacity: 128GB (when configured with 8-GB DIMMs)
NOTE: DIMMs must be installed in pairs.  Pairs of different densities may be mixed.
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS SAS support via SAS Host Bus Adapter (HBA).
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Three internal MD2 low profile 8-lane PCI Express slots (all with x16 mechanical connectors)
Internal Mass Storage
Disks SAS: Up to eight 2.5" SAS Disks with add-on SAS Host Bus Adapter
(146GB - 10000 RPM SAS, 73GB 10000 RPM SAS, or 73GB 15000 RPM SAS)
Solid State Drives Up to eight 32GB solid state drives
DVD-ROM One EIDE DVD+/-RW drive
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating DC output = 658W)
(UL Maximum AC input = 658W x 1.33 efficiency = 875W)
(8.2 Amps RMS at 100 VAC)
Environment
AC power 100-200 V / 200-240 V AC (50-60 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
LwAd (1B=10dB)
     6.6 dB at max ambient
LpAm bystander
     51 dB at max ambient
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 44 mm (1.73 in.)
Width (not including ears) 425.5 mm (16.75 in.)
Width (including ears) 443.9 mm (17.47 in.)
Depth (not including PSU handle) 711.2 mm (28 in.)
Depth (including PSU handle) 736.4 mm (28.99 in.)
Weight 18.55 kg (40.90 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Sun Fire X4140 Server Racks Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Third Party EIA-310-D-1992

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback