Processor
Number 1 or 2 Quad-Core or 6-Core
Architecture Type: Intel Xeon 5600 Processor Series
CPUs Intel 2.40GHz Quad-Core Xeon E5620, 80W
Intel 2.80GHz 6-Core Xeon X5660, 95W
Intel 2.93GHz 6-Core Xeon X5670, 95W
Cache memory 256KB unified (data and instruction) Level 2 cache
12MB shared inclusive Level 3 cache
Main Memory
Capacities DIMM slots: 12 DIMM slots, 6 slots per CPU
DIMM type: Registered DDR3-1066/PC3-8500 ECC DIMMs
DIMM size: 4GB, 8GB
Maximum capacity: 96GB
Standard Integrated Interfaces
Network Two Integrated 10/100/1000 Base-T Gigabit Ethernet
Network Management One 10/100 Base-T Ethernet port for remote management
Serial Management One TIA/EIA-232-F asynchronous RJ45 Port (rear of chassis)
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
Internal: 1 USB 2.0 Port
PCI Express Riser card assembly with one x16 electrical/x16 mechanical, low-profile, half length slot (PCIe 2.0)
Video One Rear HD15 VGA port - 1600x1200 @ 60Hz (1024x768 when viewed remotely via ILOM Service Processor)
Graphics controller ASPEED AST2000 - 2D graphics controller embedded in Optional Service Processor
Support remote console at a resolution up to 1600x1200x16bits@60Hz
Internal Mass Storage
Disks Up to 4 Hot-pluggable - 2TB SATA 3.5" (7,200RPM) disk drives
Up to 2 Hot-pluggable - 32GB Solid State Drives
Power Supplies
One 600 Watt (Non-redundant 80% efficiency) Power Supply
Environment
AC power 100-200 V/200-240 V AC (47-63Hz) Auto-sensed
Maximum Input Current 8.6Amax @ 100Vac; 4.3Amax @ 200V, full load
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 100° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 93% relative humidity noncondensing, 38° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 43° C (100.4° F) max wet bulb
Altitude Operating: Up to 3048 m (10,000 ft.), maximum operating temperature is derated by 1° C for every 300 m (985 ft) in altitude.
Nonoperating: Up to 12,000 m (39,370 ft.)
Acoustic Noise Emissions LwAd (1B= 10dB) at max ambient: 7.6 B
LpAm bystander at max ambient: 63.1 dB
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950-1, UL/CSA60950-1, EN60950-1, CB scheme with all country differences
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022 Class A, EN300-386, EN 61000-3-2, EN 61000-3-3, EN 300 386
Immunity EN 55024 ,EN 300 386
Certifications Safety: UL/cUL, CE, BSMI, GOST-R, S-Mark, CSA C22.2 No. 60950-03
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, GOSTR, BSMI Class A
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive and RoHS Directive (2002/95/EC)
RoHS Compliance Level RoHS:YL
Dimensions and Weight
Height 43 mm (1.7 in.)
Width 436 mm (17.2 in.)
Depth 650 mm (25.6 in.)
Weight 12.4 kg (27.28 lb.) minimum configuration without rack mounting slide rail kit
13.2 kg (29.04 lb.) maximum assuming PCIe card weighs 0.12 kg (0.25 lb) each and without rack mounting slide rail kit
Rack Mounting
Sun Fire X2270 M2 Server Racks (using the X8347A or X8348A kits) Racks are as follows:
  • Sun Rack 938
  • Sun Rack 1038
  • Sun Rack 1042
  • Third Party ANSI/EIA 310-D-1992 or IEC 60927 compliant racks