Processor |
Number |
Up to 2 |
Architecture |
Next-Generation AMD Opteron 2000 Series (dual core)
Model 2218HE, 2.6 GHz, F3 Stepping
Model 2222, 3.0 GHz, F3 Stepping
Model 2218, 2.6 GHz, F3 Stepping
Model 2210, 1.8 GHz, F3 Stepping
Model 2220, 2.8 GHz, F3 Stepping
Model 2214, 2.2 GHz, F3 Stepping
Next-Generation AMD Opteron 2300 Series (quad core)
Model 2346HE, 1.8 GHz, B3 Stepping
Model 2354, 2.2 GHz, B3 Stepping
Model 2356, 2.3 GHz, B3 Stepping
Model 2376, 2.3 GHz, C2 Stepping
Model 2384, 2.7 GHz, C2 Stepping
Model 2389, 2.9 GHz, C2 Stepping
x16 HyperTransport 8 GB/s (Processor to South Bridge)
x16 HyperTransport8 GB/s (CPU0 to CPU1) |
Cache memory |
1 MB Level 2 cache per core |
Main
Memory |
Capacities |
DIMM slots: 8 per processor, 16 total
DIMM type: Registered DDR2-667 ECC DIMMs
DIMM size: 1 GB, 2 GB, 4 GB
Maximum capacity: 64 GB |
Standard
Integrated Interfaces |
Network |
4 x Integrated 10/100/1000 Base-T Gigabit Ethernet
Broadcom: ports 0,1
NVIDIA: ports 2, 3 |
Network Management |
1 Dual Port 10/100/1000 Base-T Gigabit Ethernet (one of four network ports) |
Serial Management |
1 Serial DB-9 Port |
PCI Express |
2 8-lane PCI-Express Slots - accept low profile, half length cards
25 W maximum per card |
USB |
Front: 2 USB 2.0 Ports
Rear: 4 USB 2.0 Ports |
Expansion bus |
Riser card assembly with two internal 8-lane, low-profile, half length
PCI Express slots |
Graphics controller |
ASPEED AST2000 |
Internal
Mass Storage |
Disks |
Up to two - 250GB, 500GB, 750GB or 1TB 7200 RPM SATA 3.5" disk drives
Up to two - 146GB or 300GB 15000 RPM SAS disk drives |
DVD-ROM |
DVD-ROM (optional) |
Power
Supplies |
Single 450 Watt Power Supply |
Environment |
AC power |
100-240 VAC (47-63Hz) Auto-sensed |
Input Voltage Range |
Range 1: 90 Vms (minimum), 115 Vms (nominal), 132 Vms (maximum)
Range 2: 180 Vms (minimum), 230 Vms (nominal), 264 Vms (maximum) |
Input Frequency |
Range 1: 57 Hz (minimum), 60 Hz (nominal), 63 Hz (maximum)
Range 2: 47 Hz (minimum), 50 Hz (nominal), 53 Hz (maximum) |
Maximum Input Current |
8.0 Amps max @ 90VAC; 4.0 Amps max @ 180 VAC, full load |
Maximum Measured Inrush Current |
36 Amps |
Temperature |
Operating: 2° C to 38° C (36° F to 100° F)
Nonoperating: -40° C to 68° C (-40° F to 154°
F) |
Humidity |
Operating: 7% to 93% noncondensing, 38° C (80.6° F) max
wet bulb
Nonoperating: 93% noncondensing, 43° C (100.4° F) max wet
bulb |
Altitude |
Operating: up to 3000 m (9843 ft.), maximum operating temperature
is derated by 1° C for every 300 m (985 ft) in altitude. |
Vibration |
Operating: 0.12 G x-y, 0.17 G z; 5-500 Hz sine
Nonoperating: 0.3 G x-y, 0.6 G z' 5-500 Hz sine |
Shock |
Operating: 4.5 G to 3.5 G; 11 msec. half-sine
|
RoHS Compliance Level |
RoHS:YL |
Regulations
Meets or exceeds the following requirements: |
Safety |
IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences |
RFI/EMI |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003 |
Immunity |
EN55024 ,EN300-386:v1.3.2 |
Certifications |
Safety: CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark
EMC: CE Mark, Emissions and Immunity Class A Emissions Levels: FCC,
CTick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment)
Directive |
Dimensions
and Weight |
Height |
43 mm (1.69 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
633.7 mm (25 in.) |
Weight |
11.6 kg (24.64 lb.) |
Rack
Mounting |
Optional Slide Rail Kit (X8029A-Z)1 |
4-point mounted slide rail kit |
1 The slide kit includes hardware that enables
mounting to any of the following types of rack rails:
- 6 mm (M6x1) threaded holes
- #10-32 threaded holes
- #10 clearance holes
- square unthreaded holes per ANSI/EIA 310-D-1992 or IEC 60927 standards
|
Sun Fire X2200 M2 Server Racks (using the X8029A-Z kit) |
Racks are as follows:
- Sun Rack 900
- Sun Rack 1038
- Sun Rack 1042
- Third Party ANSI/EIA 310-D-1992 or IEC 60927 compliant racks
|