Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X2100 M2 Server: Hardware Specifications

Processor
Number One
Architecture Next-Generation AMD Opteron 1000 Series (dual core only) 1218 (2.6 GHz), 1214 (2.2 GHz), 1210 (1.8GHz)
x16 HyperTransport 8 GB/s (Processor to South Bridge)
Cache memory 1 MB Level 2 per core
Main Memory
Capacities DIMM slots: 4 DIMM slots
DIMM type: Unregistered DDR2-667 ECC DIMMs
DIMM size: 512MB, 1GB, 2GB
Maximum capacity: 8GB
Standard Integrated Interfaces
Network 4 x Integrated 10/100/1000 Base-T Gigabit Ethernet
Broadcom: ports 0,1
NVIDIA: ports 2, 3
Network Management 1 Dual Port 10/100/1000 Base-T Gigabit Ethernet (one of four network ports)
Serial Management 1 Serial DB-9 Port
USB Front: 2 USB 2.0 Ports
Rear: 4 USB 2.0 Ports
PCI Express Riser card assembly with two internal 8-lane, low-profile, half length PCI Express slots
25 W max per card
Graphics controller ASPEED AST2000
Internal Mass Storage
Disks Up to two - 250GB, 500GB, 750GB, or 1TB 7200 RPM SATA 3.5" disk drives
Up to two - 146GB or 300GB 15000 RPM SAS disk drives
DVD-ROM DVD-ROM (optional)
Power Supplies
Single 345 Watt Power Supply
Environment
AC power 100-240 VAC (47-63Hz) Auto-sensed
Maximum Input Current 6.5A @ 100-240V
Temperature Single, non-rack system:
Operating: 2° C to 38° C (36° F to 100° F)
Nonoperating: -40° C to 68° C (-40° F to 154° F)
Humidity Single, non-rack system:
Operating: 7% to 93% relative humidity noncondensing, 27° C (° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (° F) max wet bulb
Altitude Operating: Up to 3000 m (9843 ft.), maximum operating temperature is derated by 1� C for every 300 m (985 ft) in altitude.
Vibration Operating: 0.12 G x-y, 0.17 G z; 5 500 Hz sine
Nonoperating: 0.3 G x-y, 0.6 G z; 5 500 Hz sine
Shock Operating: 4.5 G to 3.5 G; 11 msec. half-sine
Acoustic Noise Emissions Declared noise emissions in accordance with ISO 9296, A-weighted, sound power: LwAd Idle, at or below 25� C: 6.9 B max, at ambient 7.3 B
Regulations
Meets or exceeds the following requirements:
Safety IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003
Immunity EN55024 ,EN300-386:v1.3.2
Certifications Safety: CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark
EMC: CE Mark, Emissions and Immunity Class A Emissions Levels: FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark
Other: Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive
RoHS Compliance Level RoHS:YL
Dimensions and Weight
Height 43 mm (1.69 in.)
Width 425.5 mm (16.75 in.)
Depth 633.7 mm (25 in.)
Weight 10.66 kg (23.5 lb.)
Rack Mounting
Optional Slide Rail Kit (X8029A)1 Is a 4-point mounted slide rail kit.
1 The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • 6 mm (M6x1) threaded holes
  • #10-32 threaded holes
  • #10 clearance holes
  • square unthreaded holes per ANSI/EIA 310-D-1992 or IEC 60927 standards
Sun Fire X2100 Server Racks (using the X8029A kit) Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1038
  • Sun Rack 1042
  • Third Party ANSI/EIA 310-D-1992 or IEC 60927 compliant racks

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback