Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V890 2100 Server, RoHS:YL : Hardware Specifications

Processor
Number Up to eight
Architecture

2.1GHz UltraSPARC IV+

Cache memory

64-KB data and 32-KB instruction per pipeline

Secondary: 16-MB external (8-MB per pipeline), 2-MB on chip L2 cache

Main Memory
Capacities

Total of 16 DIMM memory slots available per CPU/Memory board

512MB, 1GB, or 2GB (32GB maximum per CPU/Memory board, 128GB maximum when configured with 8 processors)

Note: Install DIMMs in groups of four.

It is REQUIRED to fully populate all memory DIMMs on 2.1GHz CPU/memory Boards

Standard Interfaces
Ethernet
  • One Gigabit ethernet (1000BASE-SX)
  • One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45)
Keyboard and mouse USB (uses one of the two standard USB (Type A) port)
PCI

PCI slots are hot-pluggable

  • Seven slots, 64 bit, operating at 33MHz (5V)
  • Two slots (slots 7 and 8), 64 bit, operating at 33 or 66MHz (3.3V)
Remote System Controller
  • One EIA-232D serial port (RJ-45)
  • One 10 Mbps Ethernet port (RJ-45)
Serial Two EIA-232D/EIA-423 serial ports (DB25) via splitter cable (X985A)
USB Two USB 1.0 ports
Internal Mass Storage
Disks Up to 12 1" 15000 RPM FC-AL disks, 146GB capacity. Maximum total capacity of 1.75TB.
DVD-ROM 16X ATAPI DVD-ROM Drive
Tape Optional 36-72GB 4 mm DAT 72 Tape Drive
Power Supplies
Type 2 minimum, 3 for N+1 redundancy, individual power cords
Output 1629W maximum per power supply
Environment
AC Power 200-240 VAC, 47-63 Hz, 2078VA
Input power 3200 W (max)
Leakage Current 3.5mA (max)
Heat output 10,912 BTU/hr (max)
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing; 27° C max wet bulb
Nonoperating: 95% relative humidity, noncondensing at 40° C
Altitude Operating: 0 to 3000 m (0 to 10,000 ft.)
Nonoperating: 0 to 12,000 m (0 to 40,000 ft.)
Acoustic noise Operating: 66.5 dBA
ok prompt: 75.7 dBA
Vibration Operating: 0.0002 G2/Hz, 5 - 500 Hz (random) (deskside)
0.00015 G2/Hz, 5 - 500 Hz (random) (rackmounted)
Nonoperating: 0.002 G2/Hz, 5 - 500 Hz (random) (deskside)
0.0015 G2/Hz, 5 - 500 Hz (random) (rackmounted)
Shock Operating: 4 G peak, 11 milliseconds half-sine pulse (deskside)
3 G peak, 11 milliseconds half-sine pulse (rackmounted)
Nonoperating: 15 G peak, 11 milliseconds half-sine pulse (deskside)
10 G peak, 11 milliseconds half-sine pulse (rackmounted)
Handling Drops 50 mm
Threshold Impact 1 m/s
Number of cords 3
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part1040, CNS14336
Ergonomics EK1-ITB-2000
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3
Immunity EN55024/CISPR24
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark
Telecommunications EN300-386
X-ray US DHHS 21 CFR Subchapter J, PTB German X-ray Decree
Dimensions and Weights
Height1 71.4 cm (28.1 in.) with castors
70.0 cm (27.6 in.) without castors
Width 48.0 cm (18.9 in.)
Depth 83.6 cm (32.9 in.)
Weight 88.0 kg (194.0 lb.)(minimum, approximate)
130.6 kg (288.0 lb.)(maximum, approximate)
Power Cord 2.5 m (8.2 ft.)
1 Rackmounting does not require the removal of castors.
Clearance and Service Access
Front Deskside - 91 cm (36 in.)
Rackmount - 122 cm (48 in.)
Rear 91 cm (36 in.)
Right 91 cm (36 in.)
Left 91 cm (36 in.)
Clearance For Proper Cooling
Front Blockage Only 7.6 cm (3.0 in.)
Rear Blockage Only 8.9 cm (3.5 in.)
Front And Rear Blockage Front Clearance: 8.9 cm (3.5 in.)
Rear Clearance: 10.2 cm (4.0 in.)
Rack Mounting
Fits into Sun StorEdge 72" Expansion Rack, Sun Fire Cabinet and Sun Rack 900. Third party racks that comply with the EIA-310-D-1992 Standard and that have a 34" (86.36 cm.) to 36" (91.44 cm.) depth rail-to-rail may be considered. The X9628A-Z rackmount kit has adjustable extenders which can accommodate rail-to-rail depths of 32" (81.28 cm.) to 36" (91.44 cm.) only and should be appropriate for these EIA Standards compliant racks. Sufficient space for cable management must be allowed. Therefore, third party cabinets with a total, externally measured depth of 36" and possibly as much as 39" may be required. Front doors to cabinets must provide at least 60% open area and rear doors at least 63% open area for the Sun Fire V890 to cool properly. Third-party products are neither tested, endorsed nor recommended.

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback