Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire 3800 : Archived FINs and FCOs

Implementation (Impl.):
M = Mandatory (Fully Pro-Active)

C = Controlled Pro-Active (per Sun Geo Plan)

U = Upon Failure
R = Reactive (As Required)

FAB Implementation Synopsis Last Modified Date
A0253-1 C A sub-population of DIMMs that shipped between 2001 and 2002 on the below platforms are showing significantly lower reliability than expected. Aug 18 2005
A0248-1 M A limited set of Sun Fire System Boards may be vulnerable to Uncorrectable Errors in L2 SRAM. Nov 05 2004
A0223-1 U On Sun systems, a small number of 256MB DIMMs may experience Uncorrectable Memory Errors (UE). Mar 23 2004
A0206-4 M A weak fuse in the Serengeti 3800/48x0/6800 standby RTS blows when the load from the primary RTS is switched over. Feb 25 2004
A0190-1 M Sunfire 3800 systems with 540-4591-02 (or lower) cPCI I/O Assemblies will not support Hot Swapping of cPCI cards. Mar 05 2002
A0187-1 M Sun Fire 3800 with cPCI card may experience system panics. Jan 08 2002
I0912-1 R Sun Fire CPU/Memory Board FRUs are not enabled for Capacity On Demand. 2003-03-04
I0887-1 R Guidelines for understanding and diagnosing UltraSPARC III Level 2 (L2) SRAM Cache Memory Errors. 2002-10-07
I0880-1 R Sun Fire 3800/4800/4810/6800 5.13.3 firmware gives warning message when USIII+ processors are installed on System Boards with Late_Write Ecache DIMMs. 2002-11-25
I0857-1 C Certain Sun Fire 3800 systems with duplicate MAC addresses running on common subnets may experience network issues 2002-08-09
I0855-1 R Sun Fire CPU/Memory Boards may become unusable when components are knocked off by improper handling 2002-08-02
I0841-1 C Sun Fire (3800/4800/4810/6800) Servers with very large storage configurations or large driver .conf files may encounter panics or hangs during bootup 2002-06-20
I0762-1 C The clock selection on an initial batch of FRU and shipped in product System Controllers is set to use a clock synthesizer causing the clock failover feature to be disabled 2002-01-30
I0708-1 R Newly installed X-6748 or FRUs may cause a panic message on Serengeti 2001-08-03
I0654-1 R Serengeti FRU numbers 2001-03-22
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.