Processor |
Number |
Up to two.
|
Architecture |
Type:Quad-core, Intel Xeon 5300 series processors.
- Model/Speed: 5160, Dual Core, 3.00 GHz, 80W
- Model/Speed: X5260, Dual Core, 3.33 GHz, 80W
- Model/Speed: X5270, Dual Core, 3.5 GHz, 80W
- Model/Speed: E5320, Quad Core, 1.86 GHz, 80W
- Model/Speed: L5310, Quad Core, 1.6 GHz, 50W
- Model/Speed: E5345, Quad Core, 2.33 GHz, 80W
- Model/Speed: X5355, Quad Core, 2.66 GHz, 120W
- Model/Speed: E5410, Quad Core, 2.33 GHz, 80W
- Model/Speed: E5440, Quad Core, 2.83 GHz, 80W
- Model/Speed: X5460, Quad Core, 3.16 GHz, 120W
- Model/Speed: E5450, Quad Core, 3.0 GHz, 80W
- Model/Speed: X5365, Quad Core, 3.0 GHz, 120W
- Model/Speed: L5420, Quad Core, 2.5 GHz, 50W
- Model/Speed: X5470, Quad Core, 3.33 GHz, 120W
- Model/Speed: L5430, Quad Core, 2.66 GHz, 50W
- Model/Speed: E5420, Quad Core, 2.5 GHz, 80W
|
Cache Memory |
4 MB, L2 Cache |
Main Memory |
Memory Type |
DDR2-667MHz / PC2-5300 ECC Registered DIMMs.
Support for ChipKill with a minimum of 4 DIMMs. |
Capacities |
- Maximum memory: 64GB.
- Total DIMM slots: 16.
- All DIMM slots are accessible by both processors.
- DIMM sizes: 1GB, 2GB and 4GB.
- Memory must be populated in increments of 4 DIMMs per socket.
|
Optional Storage |
Disk |
- Up to four optional, hot swappable, hot pluggable, SATA or SAS drives per blade.
- Mixing disk types (i.e. one SAS disk and one SATA disk) on same X6250 Server Module is not supported.
Drive Type
|
Density
|
Speed
|
Form Factor
|
RAID
|
SAS
|
146 GB
|
10,000 RPM
|
2.5"
|
RAID 0/1/5/10
|
SAS
|
73 GB
|
10,000 RPM
|
2.5"
|
RAID 0/1/5/10
|
SAS
|
300 GB
|
10,000 RPM
|
2.5"
|
RAID 0/1/5/10
|
SATA
|
80 GB
|
5,400 RPM
|
2.5"
|
**
|
SATA
|
200 GB
|
5,400 RPM
|
2.5"
|
**
|
SAS drives require the RAID Expansion Module board.
** RAID not currently supported for SATA. |
|
Solid State Drives |
- Up to 4 32GB solid state drives
|
IDE Compact Flash |
8GB Compact Flash Type II (supports Linux boot) is on the motherboard. |
Management Environment
|
Sun Blade Server Module Service Processor (SP) |
- The SP is not a separate card. It is embedded on the motherboard.
- The SP may be installed with Lights-Out Manager (LOM),
IPMI 2.0-compatible software.
- The factory pre-configured LOM transitioned from ELOM to ILOM in September 2008.
- The SP card provides one 10/100 Management Ethernet Port to Midplane and the Chassis Monitoring Module (CMM).
- LOM on the SP card can be accessed via the Dongle cable assembly's DB9 connector to the Universal Connector Port (UCP) on the front of the Sun Blade X6250.
- The Dongle cable assembly is provided with the Sun Blade 6000 chassis and also orderable. Option X4621A.
- The SP card and LOM provide the following:
- A Browser User Interface (HTTP/HTTPS).
- DMTF/CLP based CLI and SSH.
- Support for RADIUS, LDAP, and MS Active Directory.
- IPMI 2.0 (Host access through KCS and remote).
- Compatibility for third-party SNMP system managers with requirements for SNMP (v1, v2C, v3).
- Remote KVMS/Java Console (redirected Keyboard Video Mouse and Storage through a JAVA Application).
- Support for Sun N1 System Manager.
|
Standard Integrated Interfaces |
Universal Connector Port (UCP)
|
The Dongle Cable Assembly (Option X4621A) that ships with the Sun Blade 6000 chassis connects to the UCP and provides the following:
- VGA HD15 port to AST2000 video controller with 128MB of shared SDRAM.
- 2 USB 2.0 ports.
- DB9 serial port (for connection to SP LOM).
- RJ45 port. Not supported on the Sun Blade X6220 or X6250.
- DB9F to RJ45F DCE Adapter.
|
Network Management |
Two 10/100Base-T Ethernet connection via midplane to the CMM.
Only one connection (NET 0) is used.
|
Ethernet |
Two 10/100/1000Base-T Ethernet ports routed through midplane to 2 NEM slots.
|
PCI Interfaces with the Sun Blade Modular System (chassis) |
- I/O is offered in two form factors:
- PCI Express ExpressModules (EM)
and
- PCI Express Network Express Modules (NEM).
- Each Sun Blade X6250 has four, PCI Express links allocated to:
- Two EMs (X8)
and
- Two NEMs (X4).
- Each NEM has one link assigned to each server module. All server modules
share the NEM. For example, Blade 0 has access to NEM 0/slot 0,
and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
- EM slots are not shared between server modules. Each EM slot is
specific to one server module.
|
Regulations
|
RoHS Compliance Level |
RoHS:YL |
Dimensions
and Weights |
Height |
44.5mm (1.75 in). |
Width |
327.15mm (12.88 in). |
Depth |
496.82 (19.56 in). |
Weight (fully configured) |
7.51 kg (16.56 lbs). |
|
|