Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Blade T6340 Server Module: Hardware Specifications

Note: Modular System (chassis) specifications are documented on the chassis specification page. Reference the Servers/Blade section of the Handbook's Systems List to find documentation on Modular Systems.
Processor
Number Two.
Architecture Type:UltraSPARC T2 Plus processor.
  • Model/Speed:8-Core, 1.2 GHz, 103W
  • Model/Speed:8-Core, 1.4 GHz, 132W
  • Model/Speed:6-Core, 1.2 GHz, 103W
Cache Memory 4 MB L2 Cache.
Main Memory
Memory Type 1.5V DDR22-667/PC2-5300 DIMMs.
Capacities
  • Maximum memory: 256GB.
  • Total DIMM slots:32.
  • DIMM sizes: 1GB, 2GB, 4GB and 8GB.
Optional Storage
Internal Disk
  • Up to two optional, hot swappable, hot pluggable, small form factor (SFF) drive bays per blade.
Drive Type
Density
Speed
Form Factor
RAID
SAS
300 GB
10,000 RPM
SFF 2.5"
RAID 0 or 1
SAS
73 GB
10,000 RPM
SFF 2.5"
RAID 0 or 1
SAS
146 GB
10,000 RPM
SFF 2.5"
RAID 0 or 1
SAS
73 GB
15,000 RPM
SFF 2.5"
RAID 0 or 1
SATA
200 GB
5,400 RPM
SFF 2.5"
RAID 0 or 1
Solid State Drives
  • Up to 2 32GB solid state drives
Management Environment
Sun Blade Server Module Service Processor (SP)
  • The SP card is installed with Integrated Lights-Out Manager (ILOM) software.
  • ILOM can be accessed via a Dongle cable assembly connection to the Universal Connector Port (UCP) on the front of the Sun Blade T6340.
  • There are 2 different Dongle cables. A three connector and a four connector.
  • To connect to ILOM using the four connector dongle cable, use the DB-9 serial connector.
  • To connect to ILOM using the three connector dongle cable, use the RJ-45 serial connector.
  • The Dongle cable assembly is provided with the Sun Blade 6000 and Sun Blade 6048 chassis.
  • For compatibility with legacy environments, an ALOM CLI emulation mode is available.
Standard Integrated Interfaces
Universal Connector Port (UCP) Front accessible UCP provides Serial Management connection to ILOM via Dongle cable. Also provides dual USB 2.0 ports for keyboard, mouse or storage.
Network management Two 10/100Base-T Ethernet port connections via midplane to the Chassis Monitoring Module (CMM). Only one connection (NET 0) is used.
Ethernet Two 10/100/1000Base-T Ethernet ports routed through midplane to 2 NEM slots.
PCI Interfaces with the Sun Blade Modular System (chassis)
  • I/O is offered in two form factors:
    • PCI Express ExpressModules (EM)
      and
    • PCI Express Network Express Modules (NEM).
  • Each Sun Blade T6340 has four, x8 lane PCI Express links allocated to:
    • Two EMs
      and
    • Two NEMs.
  • Each NEM has one link assigned to each server module. All server modules share the NEM. For example, Blade 0 has access to NEM 0/slot 0, and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
  • EM slots are not shared between server modules. Each EM slot is specific to one server module.
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Dimensions and Weights
Height 44.5mm (1.75 in).
Width 327.15mm (12.88 in).
Depth 496.82 (19.56 in).
Weight (fully configured) 9.1 kg (20.0 lbs).

  Copyright � 2011 Sun Microsystems, Inc.  All rights reserved.