Processor |
Number |
Two.
|
Architecture |
Type:UltraSPARC T2 Plus processor.
- Model/Speed:8-Core, 1.2 GHz, 103W
- Model/Speed:8-Core, 1.4 GHz, 132W
- Model/Speed:6-Core, 1.2 GHz, 103W
|
Cache Memory |
4 MB L2 Cache. |
Main Memory |
Memory Type |
1.5V DDR22-667/PC2-5300 DIMMs. |
Capacities |
- Maximum memory: 256GB.
- Total DIMM slots:32.
- DIMM sizes: 1GB, 2GB, 4GB and 8GB.
|
Optional Storage |
Internal Disk |
- Up to two optional, hot swappable, hot pluggable, small form factor (SFF) drive bays per blade.
Drive Type
|
Density
|
Speed
|
Form Factor
|
RAID
|
SAS
|
300 GB
|
10,000 RPM
|
SFF 2.5"
|
RAID 0 or 1
|
SAS
|
73 GB
|
10,000 RPM
|
SFF 2.5"
|
RAID 0 or 1
|
SAS
|
146 GB
|
10,000 RPM
|
SFF 2.5"
|
RAID 0 or 1
|
SAS
|
73 GB
|
15,000 RPM
|
SFF 2.5"
|
RAID 0 or 1
|
SATA
|
200 GB
|
5,400 RPM
|
SFF 2.5"
|
RAID 0 or 1
|
|
Solid State Drives |
- Up to 2 32GB solid state drives
|
Management Environment
|
Sun Blade Server Module Service Processor (SP) |
- The SP card is installed with Integrated Lights-Out Manager (ILOM) software.
- ILOM can be accessed via a Dongle cable assembly connection to the Universal Connector Port (UCP) on the front of the Sun Blade T6340.
-
There are 2 different Dongle cables. A three connector and a four connector.
-
To connect to ILOM using the four connector dongle cable, use the DB-9 serial connector.
-
To connect to ILOM using the three connector dongle cable, use the RJ-45 serial connector.
- The Dongle cable assembly is provided with the Sun Blade 6000 and Sun Blade 6048 chassis.
- For compatibility with legacy environments, an ALOM CLI emulation mode is available.
|
Standard Integrated Interfaces |
Universal Connector Port (UCP)
| Front accessible UCP provides Serial Management connection to ILOM via Dongle cable. Also provides dual USB 2.0 ports for keyboard, mouse or storage.
|
Network management |
Two 10/100Base-T Ethernet port connections via midplane
to the Chassis Monitoring Module (CMM). Only one connection (NET 0)
is used.
|
Ethernet |
Two 10/100/1000Base-T Ethernet ports routed through midplane to
2 NEM slots.
|
PCI Interfaces with the Sun Blade Modular System (chassis) |
- I/O is offered in two form factors:
- PCI Express ExpressModules (EM)
and
- PCI Express Network Express Modules (NEM).
- Each Sun Blade T6340 has four, x8 lane PCI Express links allocated to:
- Each NEM has one link assigned to each server module. All server modules
share the NEM. For example, Blade 0 has access to NEM 0/slot 0,
and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
- EM slots are not shared between server modules. Each EM slot is
specific to one server module.
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Dimensions
and Weights |
Height |
44.5mm (1.75 in). |
Width |
327.15mm (12.88 in). |
Depth |
496.82 (19.56 in). |
Weight (fully configured) |