Capacity |
Number |
- Up to 24 optional, hot-pluggable PCI ExpressModules (EM) per shelf, 96 per chassis.
- Up to 2 optional, hot-pluggable PCI Express Network Express Modules (NEM) per shelf, 8 per chassis.
- Up to 12 optional, hot-pluggable Sun Blade Server Modules per shelf, 48 per chassis.
- 2 high-efficiency, hot-swappable, 1 + 1 redundant, power supply modules per shelf, 8 per chassis.
- 2 Front Fan Modules per shelf, 8 per chassis.
- 8 redundant Rear Fan Modules per shelf, 32 per chassis.
- 1 Chassis Monitoring Module (CMM) per shelf, 4 per chassis.
|
Management Environment
|
Sun Blade 6048 Chassis Monitoring Module (CMM) |
-
Sun Blade 6048 chassis-level management is provided by the CMM's Integrated Lights-Out Management (ILOM) software.
- Connect to CMM ILOM:
-
Connect a terminal or terminal emulation software to the SER MGT (RJ-45) port of the CMM to telnet into CMM ILOM.
-
Connect to the NET MGT 0 (10/100Base T ethernet) port of the CMM for Secure Shell (SSH) client access to CMM ILOM.
|
Power Supplies |
Number |
Two, hot-swappable, 1 + 1 redundant, load balancing power supplies per shelf, 8 per chassis.
|
Configurations |
- 8400 Watt power supply. Each power supply has 3 AC inputs. When
all three inputs are used, 8400 Watts of power are supplied to the chassis.
|
Standard Integrated Interfaces |
Network |
The Sun Blade 6048, without an optional EM or NEM, does not offer production network or I/O connectivity.
|
PCI Interfaces |
The Sun Blade 6048 Modular System I/O is architected using PCI Express technology. I/O is offered in two form factors: PCI Express ExpressModules (EM) and PCI Express Network Express Modules (NEM). Each server module has four PCI Express links.
There are 2 mid-plane versions: PCI Express 1.1 and PCI Express Gen 2.
|
Removable Media |
n/a
|
Environment |
AC input |
- Voltage: 200-240 VAC.
- Frequency: 50-60 Hz.
- Current: 16A per AC input.
- AC Input Connections: Dependent on location:
- AMER - L6-20P to IEC 320 C19; 2.5m; Sun PN 180-2005-01.
- EPAC - IEC 309 to IEC 320 C19; 2.5m; Sun PN 180-2004-01.
|
Temperature |
Operating: 5°C to 32°C (41° F to 90° F) non-condensing.
Nonoperating: -40°C to 65°C (-40° F to 149° F) non-condensing.
Optimum ambient temperature: <23° C (73.40° F).
|
Relative Humidity |
Operating: 10% to 90% RH, non-condensing, 27° C max wet bulb.
Nonoperating: 45% to 50% RH, non-condensing, 38° C max wet bulb. Optimum ambient relative humidity: 45% to 50% RH, non-condensing.
|
Altitude |
0 to 10,000 feet (3,048m). |
Sine Vibration |
Operating: Z (vertical)-axis: 0.15G X/Y axis: 0.10G 5 to 500 Hz sine.
Nonoperating: Z (vertical)-axis: 0.50G X/Y axis: 0.25G 5 to 500 Hz sine.
|
Shock |
3Gs, 11msec, half sine (applied to rackmounted enclosure).
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Product Safety |
- UL approved to UL 60950 and C22.2 No. 60950.
- UL Demko approved to EN60950-1 and CB Report IEC 950 3rd Edition; including all amendments and full worldwide deviations.
- GOST Certification.
- Korean MIC Certification.
- China CCC Mark for power supply only (system is exempt since it is rated greater than 1300W).
- CE Declaration of Conformance to the Electronic Compatibility Directive and Low Voltage Directive 2006/95/EC.
- IRAM S-Mark for power supply (system is exempt, due to class of equipment)
- CNS 14336 (Taiwan).
|
Laser Product and Optical I/O |
- FCC registration to Code of Federal regulations 21 CFR 1040-Lasers.
- TUV approval to IEC 60825-1 Safety of Laser Products.
- Canadian Radiation Emitting Devices Act REDR C1370.
|
Emissions and Immunities: |
Electromagnetic Interference |
- 47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A.
- EN55022:2006 Class A per EMC directive 2004/108/EEC (CE Mark).
- VCCI Class A.
- Industry Canada ICES-003.
- AS/NZ 3548 (Australia/New Zealand).
- CNS 13438 (Taiwan).
|
Immunity |
- EN55024:1998+A1:2001 +A2:2003 per EMC Directive 2004/108/ EEC, including: IEC 61000-4-2 Electrostatic discharge immunity test.
- IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test.
- IEC 61000-4-4 Electrical fast transient/burst immunity test.
- IEC 61000-4-5 Surge immunity test.
- IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields.
- IEC 61000-4-8 Power frequency magnetic field immunity test.
- IEC 61000-4-11 Voltage dips, short interruptions, and voltage variations immunity tests.
|
Line Distortion |
EN 61000-3-2 per EMC Directive 89/336/EEC. |
Voltage Fluctuations and Flicker |
EN 61000-3-3 per EMC Directive 89/336/EEC. |
Dimensions
and Weights |
Chassis Height |
2,073mm (81.61 in.). |
Chassis Width |
606.5mm (23.88 in.) |
Chassis Depth |
1,024.58mm (40.34 in.) |
Weight |
Fully configured system 1,045 kg (2,300 lbs.).