Capacity |
Number |
- Up to 20 optional, hot-pluggable PCI ExpressModules (EM).
- Up to 2 optional, hot-pluggable PCI Express Network Express Modules (NEM).
- Up to 10 hot-pluggable Sun Blade Server Modules.
- 2 (N+1), hot-plug / hot-swap 5600-Watt power supplies with independently wired fans.
- 2 Front Fan Modules (6 fans total).
- 6 Rear Fan Modules (12 fans total, N + 1 redundancy)
- One Chassis Monitoring Module (CMM).
|
Management Environment
|
Sun Blade 6000 Chassis Monitoring Module (CMM) |
-
Sun Blade 6000 chassis-level management is provided by the CMM's Integrated Lights-Out Management (ILOM) software.
- Management can be integrated into Sun and/or third-party management tools.
- Two ways to connect to CMM ILOM:
-
Connect a terminal or terminal emulation software to the SER MGT (RJ-45) port of the CMM to telnet into CMM ILOM.
-
Connect to the NET MGT 0 (10/100Base T ethernet) port of the CMM for Secure Shell (SSH) client access to CMM ILOM.
|
Power Supplies |
Number |
Two, hot-plug / hot-swap, high-efficiency(~90%) power supplies are provided in a N+1 redundant configuration.
|
Output |
5600-Watt per power supply. |
Power Calculator |
Sun Blade 6000 - Power Calculator
|
Standard Integrated Interfaces |
Network |
The Sun Blade 6000, without an optional EM or NEM, does not offer production network or I/O connectivity.
|
PCI Interfaces |
The Sun Blade 6000 Modular System I/O is architected using PCI Express technology. I/O is offered in two form factors: PCI Express ExpressModules (EM) and PCI Express Network Express Modules (NEM). Each server module has four PCI Express links.
|
Removable Media |
n/a
|
Environment |
AC input |
- Voltage: 200-240 VAC.
- Frequency: 50-60 Hz.
- Current: 16A per AC input.
- Number of AC Inputs: 4.
- Maximum in-rush current: 32A.
- Power Factor: 0.98.
- AC Input Connection: Dependent on location:
- AMER - L6-20P to IEC 320 C19; 2.5m; Sun PN 180-2005-01.
- EPAC - IEC 309 to IEC 320 C19; 2.5m; Sun PN 180-2004-01.
- Preinstalled in rack with power distribution unit
- IEC 320 C20 to IEC 320 C19.
|
Airflow Requirements |
- Airflow (maximum) airflow inlet/outlet rate):1012 CFM (Cubic Feet per Minute).
- Airflow (typical): 600 CFM (Cubic Feet per Minute).
- Airflow direction: Front to rear.
|
Temperature |
Operating: 5°C to 35°C (41° F to 95° F) non-condensing.
Nonoperating: -40°C to 65°C (-40° F to 149° F) non-condensing.
Optimum ambient temperature: <23° C (73.40° F).
|
Relative Humidity |
Operating: 10% to 90% RH, non-condensing, 27° C max wet bulb.
Nonoperating: 5% to 93% RH, non-condensing, 38° C max wet bulb. Optimum ambient relative humidity: 45% to 50% RH, non-condensing.
|
Altitude |
0 to 10,000 feet (3,048m). |
Sine Vibration |
Operating: Z (vertical)-axis: 0.15G X/Y axis: 0.10G 5 to 500 Hz sine.
Nonoperating: Z (vertical)-axis: 0.50G X/Y axis: 0.25G 5 to 500 Hz sine.
|
Shock |
3Gs, 11msec, half sine (applied to rackmounted enclosure).
|
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Product Safety |
- UL approved to UL 60950 and C22.2 No. 60950.
- TUV approved to EN60950-1 and CB Report IEC 950 3rd Edition; including all amendments and full worldwide deviations.
- GOST Certification.
- Korean MIC Certification.
- China CCC Mark for power supply only (system is exempt since it is rated greater than 1300W).
- CE Declaration of Conformance to the Electronic Compatibility Directive and Low Voltage Directive with accompanying "Technical Data
File".
- Approval to Argentinian standards.
|
Laser Product and Optical I/O |
- FCC Regulation to Code of Federal regulations 21 CFR 1040-Lasers.
- TUV approval to IEC 60825-1 Safety of Laser Products.
- Canadian Radiation Emitting Devices Act REDR C1370.
|
Emissions and Immunities: |
Electromagnetic Interference |
- 47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A.
- EN55022:1998 Class A per EMC directive 89/336/EEC (CE Mark).
- VCCI Class A.
- Industry Canada ICES-003.
- AS/NZ 3548 (Australia/New Zealand).
- CNS 13438 (Taiwan).
|
Immunity |
- EN55024:1998 per EMC Directive 89/336/EEC.
- IEC 61000-4-2 Electrostatic discharge immunity test.
- IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test.
- IEC 61000-4-4 Electrical fast transient/burst immunity test.
- IEC 61000-4-5 Surge immunity test.
- IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields.
- IEC 61000-4-8 Power frequency magnetic field immunity test.
- IEC 61000-4-11 Voltage dips, short interruptions, and voltage variations immunity tests.
|
Line Distortion |
EN 61000-3-2 per EMC Directive 89/336/EEC. |
Voltage Fluctuations and Flicker |
EN 61000-3-3 per EMC Directive 89/336/EEC. |
Dimensions
and Weights |
Chassis Height |
438.15mm (17.25 in) - 10 RU minus clearance. |
Chassis Width |
444.5mm (17.50 in). |
Chassis Depth |
692.15mm (27.25 in). |
Chassis Depth (in rack) |
27.25 inches (692 mm) (distance from front vertical mounting rail to rear of the chassis). |
Weight |
Fully configured system 160kg (350 lbs).
Empty Chassis:35.7kg (78.7lbs). |
Rack
Mounting |
Chassis=10R / 4 chassis max per 42U rack. |