| Processor |
| Number |
One to Four UltraSPARC T2 Plus, multi-core, multi-thread processors |
| Architecture |
SPARC V9 architecture, ECC protected |
| CPUs |
1.2GHz 8-Core (64 × 4 for a total of 256 concurrent threads)
1.4GHz 8-Core (64 × 4 for a total of 256 concurrent threads) |
| Cache memory |
4MB Level 2 |
| Main Memory |
| Capacities |
Total DIMM slots: 4 on each CPU board, 12 on each Memory board,
64 slots total (4 CPU and 4 Memory boards installed.)
DIMM type: FBDIMM
DIMM size: 2GB, 4GB, or 8GB
Maximum capacity: 512GB (64 × 8GB) maximum, 128GB (64 ×
2GB) minimum
|
| Standard Integrated Interfaces
|
| Network |
4 × 10/100/1000 Mbps auto-negotiating Ethernet ports
2 × 10 Gbps Ethernet ports via the two XAUI slots |
| Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
| Serial Management |
One dedicated RJ-45 port |
| Serial |
One DB-9 serial port connector |
| SAS
|
One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller |
| USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports |
| PCI Expansion Slots |
- 8 low-profile, PCI-Express slots.
- Slots 4 and 5 share the rear opening with optional 10Gbit Ethernet (XAUI) cards which plug in
behind the PCI-E connectors. When the XAUI card is used, no PCI-E card can be used in the
Corresponding PCI-E slot.
Slot #
|
Physical
|
Electrical
|
0
|
x8
|
x8
|
1
|
x16
|
x8
|
2
|
x8
|
x8
|
3
|
x8
|
x8
|
4
|
x8
|
x8
|
5
|
x8
|
x8
|
6
|
x16
|
x8
|
7
|
x8
|
x8
|
|
| Internal Mass Storage |
| Disks |
- 1 to 4 73GB 10K RPM, 73GB 15K RPM or 146GB 10K RPM SAS 2.5 inch form factor disk drives
- 1 to 4 300GB, 10K RPM SAS 2.5 inch form factor disk drives
|
| Solid State Drives |
- Up to 4 32GB solid state drives
|
| DVD-ROM |
One slimline slot-loaded DVD-R/W |
| Power Supplies |
| 4 × 1,133 Watt, hot-swappable, 2 + 2 redundant power
supply units (PSU) |
| Environment |
| Input Voltage |
100 - 240 VAC, 50-60Hz |
| Input Current |
26.3A @ 100 VAC (max)
12.6A @ 200-240 VAC (max) |
| Idle/Peak Power |
Minimum Configuration: 495 / 590 W
Maximum Configuration: 1,540 / 1,983 W |
| Maximum Operating Input Power at 100 VAC |
2,629 W |
| Heat Output |
8,970.5 BTU/hr or 9,464.4 KJ/hour |
| Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease maximum temperature as altitude
increase, 1° C/300m (1.6° F/1000ft)
|
| Humidity |
Operating: 10% to 90% relative humidity noncondensing, 27°
C (80.6° F) wet bulb
Nonoperating: 93% relative humidity noncondensing, 35° C (95°
F) wet bulb |
| Altitude |
Operating: 0 to 3000m (0 to 10,000 ft.)
Nonoperating: 0 to 12,000m (0 to 40,000 ft.) |
| Vibration |
Operating: 0.15G (z-axis), 0.10G (x,y axes) 5-500Hz sine
Nonoperating: 0.5G (z-axis), 0.25G (x,y axes) 5-500Hz sine |
| Shock |
Operating: 3G, 11 ms half-sine
Nonoperating: 1-inch roll-off free fall, front-to-back rolling directions |
Regulations
Meets or exceeds the following requirements: |
| RoHS Compliance Level |
RoHS:Y |
| Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations,
IEC825-1,2 CFR21 part 1040, CNS14336 |
| Ergonomics |
EK1-ITB-2000 |
| RFI/EMI |
EN55022 Class A, 47 CFR 15B Class, ICES-003 Class A, VCCI Class A, AS/NZ3548
Class A, CNS 13438 Class A, KSC 5858 Class A, EN61000-3-3 |
| Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC
61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
| Dimensions and Weight |
| Height |
176 mm (6.92 in.) |
| Width |
445 mm (17.5 in.) |
| Depth |
633 mm (24.9 in.) |
| Weight |
40 kg (88 lb.) (4x processors at 1.2GHz, 64x 4GB FB-DIMMs, 4x 146GB HDDs, and no PCI cards or rack mounts) |
| Clearance
and Service Access |
| Front |
910 mm (36 in.) |
| Rear |
910 mm (36 in.) |
| Rack Mounting |
| Optional Slide Rail Kit (SEVX9RK1Z) is a 4-point mounted slide rail kit. |
Optional Slide Rail Kit (SEVX9RK1Z) and optional Cable Management Arm (SEVX9CA1Z) enables the Sun SPARC
Enterprise T5440 Server to be racked in:
- Sun Rack 900 (-38 and -36N)
- Sun Rack 1000 (-38 and -42)
- Third Party ANSI/EIA-310-D-1992 or IEC 60927 compliant racks in 19-inch/482.6 mm panel width series.
|
The slide kit includes hardware that enables mounting to any of the following
types of rack rails:
- M6 threaded holes
- #10-32 threaded holes
- #10 to M6 clearance holes
- Square unthreaded holes per EIA and IEC starndards listed above
|
| Rack Density:
Sun SPARC Enterprise T5440 Server Rack Density will vary widely based on systems installed, power distribution
installation (in-cabinet, external), power source (single-phase, three-phase) and whether redundant power is required.
|